China High Quality transformer oil acidity tester Suppliers – GDND-800 Freezing Point Tester – HV Hipot
China High Quality transformer oil acidity tester Suppliers – GDND-800 Freezing Point Tester – HV Hipot Detail:
General Information
1. Transformer oil freezing point tester has the characteristics of exquisite structural design and unique manufacturing process. It conforms to GB/T 3535 and GB/T510 standards and is used to determine the pour point of petroleum products.
2. This instrument adopts compressor refrigeration technology to save energy, simple operation and long service life. Its main technical indicators such as cooling rate and cooling capacity have surpassed similar foreign products.
Working conditions
1. The instrument should be placed on a flat and stable workbench, and air convection should be minimized in the environment.
2. This product may involve flammable materials when used. It is not allowed to have an open flame (or a device that produces spark) close to it during operation.
3. When the instrument is not in use, it should be placed in a dry and ventilated place.
4. The power supply is single-phase three-wire system and must have a good grounding terminal.
5. The environmental conditions for the instrument use are: ambient temperature 5~30℃, humidity ≤85%, working power supply AC220V±10%, 50Hz.
Specification
| Refrigerant | R13 R502 |
| Cooling time | ≤100min (ambient temperature ≤30℃) |
| Stop interval | >30min |
| Stirring motor power | 22W * 2 |
| Stirring motor allows temperature rise | 80℃ |
| Power | 800W |
| Voltage | 220V±10%, 50Hz±1Hz |
| Temperature control range | room temperature ~ -70℃ |
| Temperature control accuracy | ±0.5℃ |
| Temperature display | LED |
| Temperature sensor | Pt100 |
| Timer | LED |
Product detail pictures:
Related Product Guide:
As for competitive prices, we believe that you will be searching far and wide for anything that can beat us. We can state with absolute certainty that for such quality at such prices we are the lowest around for China High Quality transformer oil acidity tester Suppliers – GDND-800 Freezing Point Tester – HV Hipot , The product will supply to all over the world, such as: Naples, Slovak Republic, Brasilia, We expect to provide products and services to more users in global aftermarket markets; we launched our global branding strategy by providing our excellent products all over the world by virtue of our well reputed partners letting global users keep pace with technology innovation and achievements with us.