China High Quality Transformer Oil Purifier Supplier – GDOH-II insulating Oil Gas Content Tester – HV Hipot
China High Quality Transformer Oil Purifier Supplier – GDOH-II insulating Oil Gas Content Tester – HV Hipot Detail:
General Information
GDOH-II Insulating Oil Gas Content Tester is a new generation tester adopts imported high accuracy sensor and the newest sensor technology. It is based on the DL423-91 power industry standard and relevant national standards. It is more practical, more stable and reliable in performance, easy to operate and more suitable for the determination of gas content in ultra-high voltage oil-filled equipment. It is an ideal test equipment for laboratory.
Features
● The all-metal structure avoids the problems of fragility and poor sealing of the glassware tester.
● The application of high precision and high stability imported differential pressure sensor makes the test data more accurate and repeatable.
● The test circuit contains the sensors that measure atmospheric pressure and ambient temperature. No matter where you are, you can automatically measure the ambient temperature and atmospheric pressure at your location, automatically convert to the gas content at 0° under standard atmospheric pressure, and display it directly on the LCD screen
● The unique gas injection anti-standard test program allows you to easily check whether the instrument is calibrated or measured correctly.
● The oil sample test time is short, and all test time takes only about 7 minutes.
● During the test, the operation of the vacuum pump is controlled by the instrument according to the state, which greatly reduces the noise and prolongs the service life of the vacuum pump.
● The instrument can automatically store the last dozen test data, and store the test time, temperature, atmospheric pressure, etc., so that you can easily check the data.
● With printing function, you can print test data according to your requirements.
● The same oil sample can be selected for the number of tests. After the test is completed, the single and average results will be displayed on the display or printed.
Specifications
|
High-precision electronic differential pressure sensor |
Resolution is not less than 0.1%. |
|
|
Minimum detection limit |
No more than 0.2%. |
|
|
Accuracy |
The relative error of the repeated measurement results should not exceed the following values: |
|
|
Gas content in oil (volume fraction), % |
Relative error,% |
|
|
< 0.5 |
10 |
|
|
0.5~1.0 |
8 |
|
|
1.0~3.0 |
5 |
|
|
>3.0 |
3 |
|
|
Degassing room temperature control range |
5℃ to 70℃ above room temperature |
|
|
Working power supply |
AC 220V±10%, 50Hz |
|
|
Dimension |
450*325*350 mm |
|
|
Weight |
About 20kg |
|
Accessory
| Tester | 1 set |
| Power cord | 1 piece |
| Vacuum pump & connector | 1 set |
| 3mm stainless steel pipe | 1.5m, 0.5m |
| Syringe connector | 1 set |
| Fuse 10A | 3 pieces |
| M8×1 nut | 10 pieces |
| Seal | 10 pieces |
| Syringe bracket | 1 piece |
| 1mL calibration syringe | 1 piece |
| Rotary vane vacuum pump | 1 set |
| Instruction Manual | 1 copy |
| Product certification | 1 copy |
| Factory test report | 1 copy |
| Packing list | 1 copy |
Product detail pictures:
Related Product Guide:
We pursue the administration tenet of "Quality is exceptional, Assistance is supreme, Reputation is first", and will sincerely create and share success with all clients for China High Quality Transformer Oil Purifier Supplier – GDOH-II insulating Oil Gas Content Tester – HV Hipot , The product will supply to all over the world, such as: Maldives, Germany, Malaysia, To win customers' confidence, Best Source has set up a strong sales and after-sales team to provide the best product and service. Best Source abides by the idea of "Grow with customer" and philosophy of "Customer-oriented" to achieve cooperation of mutual trust and benefit. Best Source will always stand ready to cooperate with you. Let's grow together!