China High Quality Unit Of Measurement For Capacitor Supplier – AC DC High Voltage Divider – HV Hipot
China High Quality Unit Of Measurement For Capacitor Supplier – AC DC High Voltage Divider – HV Hipot Detail:
GDFR-C1 series AC/DC Voltage Meter
GDFR-C1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. It consists of voltage divider and measurement instrument.
Features
● Balance type equal potential shield structure.
● Fully-sealed insulation cylinder with internal excellent components.
● High accuracy and linearity, good stability and anti-interference ability.
● The voltage ratio can be customized, suitable for calibration.
● Upside down is forbidden when installation.
Technical Specifications
| Model No. | GDFR-C1-50 | GDFR-C1-100 | GDFR-C1-150 | GDFR-C1-200 | GDFR-C1-300 | GDFR-C1-400 |
| Voltage(kV) | 50 | 100 | 150 | 200 | 300 | 400 |
| DC frequency (Hz) | <2 | |||||
| AC frequency (Hz) | 30-300 | |||||
| Accuracy | AC: 1.5%/DC: 1.0% | |||||
| Accuracy for option (G type) | AC: 1.0%/DC: 0.5% | – | ||||
| Accuracy for option (H type) | AC: 0.5%/DC: 0.5% | – | – | |||
| Impedance (MΩ) |
650 | 1280 | 2000 | 2640 | 4000 | 5360 |
| Capacitance (pF) |
320 | 250 | 400 / 160 | 300 | 200 | 300 |
| Voltage ratio | 1000:1 or 10000:1(or customized) | |||||
| Dimension (mm) |
150×150 | 160×160 | 350×350 | 800×800 | 1000×1000 | |
| Cable impedance(Ω) | 50 / 75 | |||||
| Range | 1. Low range: 0-20kV 2. High range: 20kV-rated voltage 3. Low range: 0-200kV 4. High range:200kV-rated voltage |
|||||
| Cable length(m) | 3 | 4 | 6 | 6 | 10 | 10 |
| Weight(kg) | 5.5 | 9.5 | 12.5 | 14.5 | 27 | 40 |
| Packing Medium | Polyurethane foaming agent | |||||
| Operation temperature | 0℃-45℃ | |||||
| Relative humidity | <85%RH, no condensation | |||||
| Altitude | <1500m (or customized) | |||||
| Use condition | Indoor use or outdoor use in Sunny day | |||||
Product detail pictures:
Related Product Guide:
Our target is always to satisfy our customers by offering golden support, superior value and high quality for China High Quality Unit Of Measurement For Capacitor Supplier – AC DC High Voltage Divider – HV Hipot , The product will supply to all over the world, such as: Sudan, Greenland, Chile, If any item be of interest to you, you should let us know. We will try our best to satisfy your requirements with high quality goods, the best prices and prompt delivery. You should feel free to contact us at any time. We will reply you when we receive your inquiries. Make sure you note that samples are available before we start our business.