GDJS-65 Insulation Gloves Test Set
It is used to test insulation performance for insulation gloves, boots, mats, hats, rod, Electroscope etc. It can test 6pcs insulation gloves/boots at the same time, also 5pcs insulation rods.
Features
Manual control unit
● Digital and real time display HV voltage, LV current, 6-way leak current and time.
● With leak current meter and over-current protection meter.
● With movable control unit, easy wiring and testing.
● Manual control, safety and reliability.
● With zero, power, operation, timing indicators.
● With over-current protection, zero-start protection, sound and light alarm, power protected switch.
● New type timer, broader timing range.(1s-99h).
Other features
● HV source is oil immersed type testing transformer.(dry type and SF6 gas type for option.)
● It is suitable for testing insulation gloves(boots), 6-110kV insulation rod and 6-110kV electroscope.
● To make test for insulation gloves and boots, the HV electrode is chain type, which the height can be adjusted. The material is stainless steel with CU/EpNi5bc painted, which make surface discharge<10pc. 6pcs insulation barrels are also supplied.
● The electrode of insulation boots is red cooper voltage-sharing type, the HV inside the bottom of boots are equal distribution. 4mm steel balls supplied, not using traditional way that injecting water.
● With insulation rod stand to make withstand voltage and leak test for insulation rod.(Optional)
● With electroscope testing device to make start voltage, in-phase, out-phase interference test for electroscope. (Optional)
● With electrode for withstand voltage and leak test of insulation mat and blanket. (Optional)
● Control unit and HV unit are separate, to ensure safety.
● If there is breakdown or over limits, the HV output will be cut off automatically and alarm.
Specifications
● Rated capacity: 5kVA
● Input voltage: AC220V±10%, 50Hz±1
● Output voltage: 0-50kV
● Voltage accuracy: ≤ 2.0%(F.S)
● LV current: 0-25A
● Leak current: 0-20.0mA
● Resolution of leak current: 0.1mA
● Current accuracy: ≤1.5%
● Timing range: 0-99h
● Environmental temperature: -20℃-50℃
Product detail pictures:
Related Product Guide:
With this motto in mind, we've got develop into amongst one of the most technologically innovative, cost-efficient, and price-competitive manufacturers for China High Quality Vlf Tester Price Exporters – Insulation Materials Hipot Test Set GDJS-65 – HV Hipot , The product will supply to all over the world, such as: Ghana, Iraq, kazan, We have 48 provincial agencies in the country. We also have stable cooperation with several international trading companies. They place order with us and export products to other countries. We expect to cooperate with you to develop a larger market.