China High Quality Voltage Capacitor Manufacturers – AC Dielectric Test Equipment with manual control unit GDYD-D – HV Hipot
China High Quality Voltage Capacitor Manufacturers – AC Dielectric Test Equipment with manual control unit GDYD-D – HV Hipot Detail:
Application

Features
● Digital (Pointe) display panel mounted controls & indicators with easy-to-read legend.
● Monitoring high voltage side voltage, low voltage side current and indicator of zero, power, working start, timing.
● Over-current protection, zero-starting protection, sound, and light alarm.
● Continuously variable output from zero to full voltage.
● Adjustable over current protection, with trip levels variable from 10 to 110%.
● With new type time relay, time range is wider (1S ~ 99H).
● Using the latest current relay, more accurate and reliable.
● Light weight, small size, easy to move.
Technical Specifications
● Input voltage: AC 220V or 380V
● Output voltage of control unit: AC 0-250V or 0-430V
● Output current of control unit:0-5/10/15/50A(customized)
● Capacity: 0-3/5/10/15/20/30/50/100kVA(customized)
● Output voltage of HV unit: 0-50/100/150/200kV(customized)
● Output current of HV unit: 0-50/100/150/200/500/1000/2000mA(customized)
● Timing: 0-9999s
● Environmental temperature: -20℃–50℃
● Voltage accuracy: ≤ 1.5%±1digit (F.S)
● Current accuracy: ≤ 1.5%±1digit (F.S)
Other accessories for option

We can customize different ratings based on different requirement. Welcome to consult with us!
Product detail pictures:
Related Product Guide:
We support our prospective buyers with ideal top quality merchandise and superior level provider. Becoming the specialist manufacturer in this sector, we have now attained abundant practical expertise in producing and managing for China High Quality Voltage Capacitor Manufacturers – AC Dielectric Test Equipment with manual control unit GDYD-D – HV Hipot , The product will supply to all over the world, such as: Uruguay, France, Nigeria, Now, with the development of internet, and the trend of internationalization, we've got decided to extend business to overseas market. With the propose of bringing more profits to oversea customers by providing directly abroad. So we have changed our mind, from home to abroad, hope to give our customers more profit, and looking forward to more chance to make business.
This company has a lot of ready-made options to choose and also could custom new program according to our demand, which is very nice to meet our needs.