DRM-20S DC Winding Resistance Tester

DRM-20S DC Winding Resistance Tester

Brief Description:

The DRM-20S three-phase DC winding resistance meter is a precision device that measures winding resistance to efficiently diagnose potential problems such as coil material defects, poor welding, loose connections, and broken wires. It integrates magnetic assist testing, three-phase testing (Yn, Y, and △ types), and demagnetization functions to fully meet the measurement needs of various winding structures.


Product Detail

Product Tags

Features

• An innovative solution that allows for full testing with a single wiring connection, improving on-site testing efficiency.

• Flexible switching between multiple modes, including single- and three-phase Yn-type simultaneous testing and three-phase Y-type and △-type phase-by-phase testing, meets diverse testing needs.

• Three-phase automatic testing and precise calculation of three-phase imbalance ratios provide quantitative winding performance data, enabling accurate analysis of test results.

• Yn winding neutral point lead wire resistance testing minimizes deviations from single-phase test standards and enhances data reliability.

• Built-in demagnetization and assist functions provide core technical support for test data accuracy.

• Equipped with a 7-inch full-touch smart screen with a 400cd/m² high-brightness display, the device offers smoother touch operation and a clearer viewing experience.

• Supports fixed and automatic outputs, accurately adapting to the test product's resistance value and empowering the device with adaptive adjustment capabilities.•

• Multiple protection mechanisms, including power failure, back EMF, and disconnection, provide a robust safety barrier for the device and testers. 9. Integrated smart printing function makes test result output more efficient and convenient.

Specifications

Output current

Single phase: 20A, 10A, 5A, 1A, 0.1A, 10mA, <1mA

Three-phase: 10A+10A, 5A+5A, 1A+1A, 0.1A+0.1A

Measuring range

Single phase:

20 A: 0.5mΩ~ 1 Ω

10 A: 1.0mΩ~2 Ω

5 A:10 mΩ~4 Ω

1 A: 0.1Ω~20Ω

0.1A: 2.0Ω~200Ω

10mA: 50Ω~2kΩ

<1mA: 500Ω~25kΩ

Three phases:

10A + 10A: 0.5mΩ ~ 0.8 Ω

5 A + 5 A: 10 mΩ ~ 1.6 Ω

1 A + 1 A: 0.1 Ω ~ 8.0 Ω

0.1A+0.1A: 2.0 Ω ~ 80 Ω

Accuracy

±(reading*0.2%+2 words)

Display

7-inch large, industrial-grade, high-brightness color LCD

Working power supply

AC220V, 50Hz

Operating temperature

-10℃~50℃

Relative humidity

<90%, no condensation

Instrument volume

400*315*223mm

Instrument weight

9kg