GIT-450kVA/150kV PD-free AC Dielectric Test Set

GIT-450kVA/150kV PD-free AC Dielectric Test Set

Brief Description:

The GIT-450kVA/150kV PD-free AC Dielectric Test Set is an advanced automatic withstand voltage tester designed in accordance with the latest national power industry standards. It utilizes PLC controller technology, 2.4G ISM networking, and an advanced human-machine interface. This test equipment is suitable for power frequency withstand voltage testing and partial discharge testing of high-voltage electrical equipment of 150kV and below.The max. capacitance of tested object is 0.05μF at 150kV.


Product Detail

Product Tags

Features

Automatic mode

•10-inch color LCD display, programmable controller PLC automatic control.

•HV voltage, HV current, LV voltage, LV current are collected isolate and synchronously, with high-precision sensor and high-performance collection chip.

•The human-machine interface adopts full touch and partial key operation mode, intelligent work process, automatic mode and manual mode for option.

•HV voltage, HV current, LV voltage, LV current, time and the HV curve dynamic can be displayed, clear and obvious.

• With over-voltage, over-current protection, and flashing protection. Set the output voltage, high voltage protection current, low voltage protection current (hardware is set up), milliammeter protection current and timing.

• Support stage boost (5 stages), and the voltage value of each stage can be set arbitrarily, making it easier to find test product problems.

• Zero-starting function. Test can be proceeded after the voltage is back to zero.

•With a local storage space of 8,000 records/3 months and provides a USB interface for exporting data to an external USB flash drive.

• When setting voltage is arrived, it will be timing automatically. After timing, voltage will be back to zero.

• When the HV current and LV current are over setting value, the voltage will be cut off automatically and it will be back to zero. When the flash-over setting value is exceeded, the voltage will be cut off automatically and back to zero.

•Software and hardware anti-interference design, adapting to the harsh electromagnetic environment.

• Automatic error diagnosis, easy to discover and solve problems, with simple and convenient maintenance.

Manual mode

• Monitoring functions: HV voltage, LV current, HV current, compensation current, zero indication, power indication, operating indication, and timing indication.

• Protection functions: Over-current protection, zero position start protection, and audible and visual alarms.

• Adopts a new time relay with a wider timing range (1S to 99 H).

• Adopts a new current relay.•

Condition of Use

• Power supply voltage: AC 415V, the waveform distortion rate is not more than 3%.

• Ambient temperature: -10°C-40°C

•Ambient humidity: ≤90%RH, no condensation, no flickering of the instrument

• Altitude: ≤1000m

• The working environment should be free from obvious dust, smoke, corrosive, flammable gas, water vapor and salt spray, and no serious vibration;

Specifications

Control unit

• Input voltage: AC 415V±10%, 50Hz±1

• Output capacity: 450kVA (Max. compensation capacity 400Kvar)

•Output voltage : AC 0-400V

• LV voltage: AC 0~1000V

• Output current: 120.5A

•Compensation capacity:

•Adjustable compensation capacity 10Kvar/20Kvar/30Kvar/40Kvar/50Kvar, Fixed compensation capacity: 50Kvar/100Kvar/200Kvar

• Output current measurement range: 0-120A   Resolution: 0.1A

• Output voltage measurement range: AC 0~400V   Resolution: 0.1V

•Compensation current measurement range: 0-400A   Resolution: 1A 

Manual part 

• LV voltage measurement range: 0-1000V   Resolution: 1V

•LV current measurement range: 0-450A    Resolution: 1A

•HV voltage measurement range: AC 0-150kV   Resolution: 0.1kV

• HV current measurement range: AC 0-3A   Resolution: 0.01A

• Timer range: 0-99H

• Voltage accuracy ≤±3% (10%-100% of the range)

•Current accuracy ≤±3% (10%-100% of the range)

Automatic part

• LV voltage measurement range: 0-1000V   Resolution: 0.01kV

• LV current measurement range: 0-450A    Resolution: 0.01A

• HV voltage measurement range: AC 0-150kV   Resolution: 0.01kV

• HV current measurement range: AC 2.0-3000mA   Resolution: 0.1mA

• Timer range: 0-999S

• Voltage accuracy ≤±3% (10%-100% range)

• Current accuracy ≤±3% (10%-100% range)

• Dimensions: 1595*1000*1365, weight: 620kg