GLF-314 SF6 Gas Infrared Imaging Leak Detector

GLF-314 SF6 Gas Infrared Imaging Leak Detector

Brief Description:

The SF6 infrared imaging leak detector is a non-contact gas imaging leak detection device that can detect possible gas leaks at several meters or tens of meters. It can quickly scan a large detection area and accurately find leaks in real time.

 The gas detection thermal imager can detect the leakage or unorganized emission of organic volatiles, and still has good performance even for very small gas leakage.

 The use of gas leakage detection is an efficient and reliable solution, which can detect the leakage of natural gas products in various links such as transportation, storage and production, so as to maximize safety and save costs.


Product Detail

Product Tags

GLF314

Features

● Intuitive display of gas leak status in real time.

● Gas-enhanced infrared mode to detect very small gas leaks.

●  Embedded operating system, UI design similar to mobile phone and tablet makes it easy for users to get started.

● USB, WiFi, HDMI multiple data transmission methods.

● High-resolution rotatable LCD display.

● High-resolution viewfinder with adjustable angle for bright light.

● Lightweight, robust design.

● Anti-fatigue ergonomic design.

Standard Configuration

● Thermal imager host

● Power adapter

● Lithium-Ion rechargeable batteries and chargers

● USB cable

● HDMI video cable

● 32G TF memory card and card reader

● User manual

● Packing box

Specifications

N0.

Items Specifications

1

Detector and optical parameters

Detector type

Uncooled infrared detectors

2

Infrared resolution

384×288

3

Pixel spacing

25μm

4

Filter bandpass response wavelength

7μm–8.5μm、9.5μm -12μm

5

Thermal sensitivity (NETD)

<0.1℃@30℃

6

Detectable gas

7μm–8.5μm:CH4

9.5μm -12μm: SF6

7

Infrared lens

Standard lens(21.7°±2°)× (16.4°±2°)

8

Infrared focus

Manual & auto

9

Image display

Digital zoom

1 to 10 times continuous digital zoom

10

Image frame rate

50Hz±1Hz

11

Display resolution

1024×600

12

Display screen

5-inch touch screen, resolution 1024×600

13

Viewfinder

OLED high-resolution display, 1024 x 600 pixels

14

Display mode

Infrared mode.

Gas boost mode.

Infrared temperature measurement mode.

Visible light mode.

Picture-in-picture mode.

Fusion mode;

15

Image adjustment

Automatic and manual brightness and contrast adjustment

16

Palette

10 types + 1 user-defined

17

Digital camera

The field of view is consistent with the infrared lens

18

LED lights

Yes

19

Temperature measurement and analysis

Temperature measurement range

1 gear: -20 — 150°C

2 gear: 100 — 650°C

20

Accuracy

±3℃or ±3%(Take the larger value, the ambient temperature is 15°C to 35°C)

21

Center point temperature measurement

Yes

22

Movable point temperature measurement

Supports 10 points

23

Movable area temperature measurement

Supports 10 circles and 10 rectangles

24

Movable line temperature measurement

Supports 10 lines

25

High and low temperature point positioning

Support full-screen high and low temperature point positioning and high and low temperature point positioning in the area

26

Measurement presets

No measurement, center point, maximum temperature point, minimum temperature point, average temperature

27

Temperature alarm

Color alarms (isothermal lines): above/below specified temperature levels, between specified temperature levels.

Measurement function alarms: Audible alarms (above/below/between specified temperature levels).

28

Measured value correction

Emissivity (0.01 to 1.0 selectable), reflected temperature, relative humidity, atmospheric temperature, target distance, external ir window compensation

29

Date storage

Storage medium

Removable TF memory card

30

Take pictures regularly

3 seconds to 24 hours

31

Native full radiometric image analysis

Saved radiometric thermal images can be edited and analyzed on the camera

32

Image file format

Standard JPEG images, including digital photographs and full radiometric data

33

Radiometric infrared video recording

Real-time radiation video recording, *.raw file is stored in TF card

34

Non-radiative infrared video recording

*.avi video file, save to TF card

35

Image annotation

Voice: 60 seconds, stored with image

Text: Add table, choose between predefined templates

36

Remote display view

View video streams in real-time over a Wi-Fi connection.

Connect to display via HDMI high-definition interface;

37

Remote operation control

Connect to dedicated software control via Wi-Fi;

38

Communication and peripherals

interface

USB 2.0, Wi-Fi, HDMI

39

WIFI

Yes

40

Audio

Microphone and speaker for image voice annotation and video recording

41

laser pointer

Yes

42

GPS

Support satellite positioning, location information can be saved in the image

43

Power supply

Battery type

Rechargeable lithium electronic battery

44

Battery voltage

7.4v

45

Continuous working time

Not less than 4 hours at room temperature

46

External power supply

Support external dc12v power supply

47

Power management

Automatic shutdown or automatic screen off, the time can be selected from never, 5min, 10min, 30min

48

Environmental adaptability

 

Operating temperature

-20 - +50℃

49

Storage temperature

-40 - +70℃

55

Physical properties

Weight (without battery)

≤ 1.8 kg

56

Dimensions

(H*W*L)

≤185 mm × 148 mm × 155 mm (including standard lens)

57

Tripod mount base

Standard, 1/4"-20

Features

● Intuitive display of gas leak status in real time.

● Gas-enhanced infrared mode to detect very small gas leaks.

●  Embedded operating system, UI design similar to mobile phone and tablet makes it easy for users to get started.

● USB, WiFi, HDMI multiple data transmission methods.

● High-resolution rotatable LCD display.

● High-resolution viewfinder with adjustable angle for bright light.

● Lightweight, robust design.

● Anti-fatigue ergonomic design.

Standard Configuration

●Thermal imager host

●Power adapter

●Lithium-Ion rechargeable batteries and chargers

●USB cable

●HDMI video cable

●32G TF memory card and card reader

●User manual

●Packing box

Specifications

N0.

Items Specifications

1

Detector and optical parameters

Detector type

Uncooled infrared detectors

2

Infrared resolution

384×288

3

Pixel spacing

25μm

4

Filter bandpass response wavelength

7μm–8.5μm、9.5μm -12μm

5

Thermal sensitivity (NETD)

<0.1℃@30℃

6

Detectable gas

7μm–8.5μm:CH4

9.5μm -12μm: SF6

7

Infrared lens

Standard lens(21.7°±2°)× (16.4°±2°)

8

Infrared focus

Manual & auto

9

Image display

Digital zoom

1 to 10 times continuous digital zoom

10

Image frame rate

50Hz±1Hz

11

Display resolution

1024×600

12

Display screen

5-inch touch screen, resolution 1024×600

13

Viewfinder

OLED high-resolution display, 1024 x 600 pixels

14

Display mode

Infrared mode.

Gas boost mode.

Infrared temperature measurement mode.

Visible light mode.

Picture-in-picture mode.

Fusion mode;

15

Image adjustment

Automatic and manual brightness and contrast adjustment

16

Palette

10 types + 1 user-defined

17

Digital camera

The field of view is consistent with the infrared lens

18

LED lights

Yes

19

Temperature measurement and analysis

Temperature measurement range

1 gear: -20 — 150°C

2 gear: 100 — 650°C

20

Accuracy

±3℃or ±3%(Take the larger value, the ambient temperature is 15°C to 35°C)

21

Center point temperature measurement

Yes

22

Movable point temperature measurement

Supports 10 points

23

Movable area temperature measurement

Supports 10 circles and 10 rectangles

24

Movable line temperature measurement

Supports 10 lines

25

High and low temperature point positioning

Support full-screen high and low temperature point positioning and high and low temperature point positioning in the area

26

Measurement presets

No measurement, center point, maximum temperature point, minimum temperature point, average temperature

27

Temperature alarm

Color alarms (isothermal lines): above/below specified temperature levels, between specified temperature levels.

Measurement function alarms: Audible alarms (above/below/between specified temperature levels).

28

Measured value correction

Emissivity (0.01 to 1.0 selectable), reflected temperature, relative humidity, atmospheric temperature, target distance, external ir window compensation

29

Date storage

Storage medium

Removable TF memory card

30

Take pictures regularly

3 seconds to 24 hours

31

Native full radiometric image analysis

Saved radiometric thermal images can be edited and analyzed on the camera

32

Image file format

Standard JPEG images, including digital photographs and full radiometric data

33

Radiometric infrared video recording

Real-time radiation video recording, *.raw file is stored in TF card

34

Non-radiative infrared video recording

*.avi video file, save to TF card

35

Image annotation

Voice: 60 seconds, stored with image

Text: Add table, choose between predefined templates

36

Remote display view

View video streams in real-time over a Wi-Fi connection.

Connect to display via HDMI high-definition interface;

37

Remote operation control

Connect to dedicated software control via Wi-Fi;

38

Communication and peripherals

interface

USB 2.0, Wi-Fi, HDMI

39

WIFI

Yes

40

Audio

Microphone and speaker for image voice annotation and video recording

41

laser pointer

Yes

42

GPS

Support satellite positioning, location information can be saved in the image

43

Power supply

Battery type

Rechargeable lithium electronic battery

44

Battery voltage

7.4v

45

Continuous working time

Not less than 4 hours at room temperature

46

External power supply

Support external dc12v power supply

47

Power management

Automatic shutdown or automatic screen off, the time can be selected from never, 5min, 10min, 30min

48

Environmental adaptability

 

Operating temperature

-20 - +50℃

49

Storage temperature

-40 - +70℃

55

Physical properties

Weight (without battery)

≤ 1.8 kg

56

Dimensions

(H*W*L)

≤185 mm × 148 mm × 155 mm (including standard lens)

57

Tripod mount base

Standard, 1/4"-20


  • Previous:
  • Next:

  • Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us