China High Quality multi phase programmable relay test set Factories – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot
Features A. Working conditions 1. Power supply: AC 220V±10%,50Hz 2. Working environment: Temperature -10℃~40℃; Humidity: ≤85% 3. Atmosphere: 86-106kPa B. Output power supply 1. AC voltage: 0-220V/3A Adjustable 2. AC current: 0-100A/7V (200A can be customized); 0-20A/25V Adjustable; 0-5A/5V Adjustable 3. DC voltage: 0-220V/3A Adjustable 4. DC current:0-20A/25V 5. Fixed voltage output: DC 24V/48V/110V/220V 6. Current/Voltage accuracy: ±1%. C. Performance Index 1. Ammeter and voltmeter: 41/2 digit. 2. Digital millisecond meter: 0-99.9999s(999.999s can be customized) Resolution: 0.1ms. D. Functions 1. Measure relay: Measure start value, return value and drop-off to pick-up ratio of current, voltage relay. 2. Time relay: Measure start value, return value and action time. 3. Intermed... -
China High Quality Dc Circuit Breaker Price Supplier – GMDL-02A HV Circuit Breaker Analog Device – HV Hipot
General Information GMDL-02A high-voltage circuit breaker simulation device is manufactured using the principles of large-scale field programmable gate arrays, power electronic devices with protection, etc. The open coil is designed according to an independent loop, which can simulate the three-phase and split-phase operation of the voltage level of 6-110KV. The action behavior of the single open coil circuit breaker is suitable for the selection of power systems, industrial and mining enterprises, scientific research institutes, professional colleges, and protection manufacturers. It is used as a substitute for actual circuit breakers in the transmission test of the entire system of relay protection and automatic devices with switches. The action is accurate, reliable, and the numbe... -
China High Quality motor winding resistance test Exporters – Online Monitoring System of Circulating Current on Cable Sheath GDCO-301 – HV Hipot
General Information Cables above 35kV are mainly single-core cables with metal sheath. Since the metal sheath of the single-core cable is hinged with the magnetic field line generated by the AC current in the core wire, the two ends of the single-core cable have a high induced voltage. Therefore, appropriate grounding measures should be taken to keep the induced voltage within the safe voltage range (usually no more than 50V, but no more than 100V with safety measures). Usually, the metal sheath of short line single-core cable is grounded directly at one end and grounded through gap or protection resistor at the other end. The metal sheath of long line single – core cable is grounded by three – phase segmental cross – connection. No matter which kind of grounding me... -
China High Quality Vacuum Capacitance Factories – Variable Frequency AC Resonant Test System – HV Hipot
Features ● Small size, light weight, portable design. ● Suitable for 35kV or below cables. ● Single parts not more than 30kg, easy to carry. ● 220V or 380V single phase power supply,convenient for on-site power sourcing. Specifications ● Rated output voltage: based on cable voltage, usually it is 2Uo or 3Uo. ● Output frequency: 20 -300Hz. ● Resonant voltage waveform: sine wave, THD ≤ 1%. ● Full load working time: continuous working time 60mins. ● Quality factor: max. load ≥ 20. ● Frequency adjustment: fineness 0.1Hz, instability ≤ 0.01%. ● Power supply: 220V or 380V single-phase. -
OEM Best Cable Fault Locator Suppliers – GD-7018A Optical Fiber Identifier – HV Hipot
The GD-7018 series optical fiber pipeline identifier can accurately locate and meaure depth of the underground pipelines, cables and optical cables under the condition of without digging, and accurately find the damage points of the outer coating of the underground pipelines and the location of the underground cable fault points. The instrument incorporates the most advanced technologies such as ultra-narrow band filter, Bluetooth wireless communication, GPS positioning, automatic data mapping by professional data analysis software and automatic generation of test reports. The detection and inspection of various kinds of metal pipelines, pipeline management and maintenance, municipal planning and construction, pipeline inspection in power supply and other departments is one of the neces... -
OEM Best Voltage And Pluse Generator Suppliers – GDCL-20kV/10kA Impulse Combination Wave Test System Technical Solution – HV Hipot
Application The equipment is according to combination wave testing requirement of the low-voltage power distribution system SPD II product, enable to generate impulse voltage (1.2/50μs) and impulse current (8/20μs), is used for grade III test and limiting voltage test of SPD and components. It is also used for impulse current test and residual voltage test of the MOV valve plate, unit and surge protective device(SPD), or used in other scientific research experiments. The device uses touch screen and PLC control technology, and the main performance meets the needs of domestic and foreign SPD products and their components for various combination wave testing. Standards ● GB 18802.1-2012 GB 18802.1-2012 Surge protective devices connected to low-voltage power distribution systems Par... -
OEM Best Sf6 Multi Analyzer Manufacturer – GDIR-1000L SF6 Gas Infrared Imaging Leak Detector – HV Hipot
Product Description GDIR-1000L SF6 Gas Infrared Imaging Leak Detector is a highly technical instrument which is independently developed by our company and has independent intellectual property rights. It is specially used to directly observe the leakage of SF6 gas equipment in the operation of the electric power industry. It uses infrared imaging principle and unique image processing algorithm, to ensure test sensitivity and reducibility of the instrument. Simple and reliable operation, high test sensitivity, the image is intuitionistic and clear, able to find the SF6 gas leakage point of the electrical equipment accurately and quickly. Features ● Infrared imaging detection, visualization. ● Fast Start-up, no need to warm up, and 10 seconds can be put into detection. ● No need for... -
China High Quality Simulate Lightning Impulse Factories – GD6100 Insulation Oil Tan Delta Tester (Oil Dissipation Factor Tester) – HV Hipot
General Information GD6100 is high-precision instrument for testing dielectric loss angle and volume resistivity of insulating oil or other insulating liquids. With its integrated structure, it contains major components such as dielectric loss oil cup, temperature controller, temperature sensor, dielectric loss test bridge, AC testing power supply, standard capacitors, Megger, DC high voltage source. Features ● Advanced high-frequency induction heating mode, homogeneous heating, high speed, and easy to control. ● All digital technology, automatic measurement. ● Large LCD screen, with printer. ● AC-DC-AC power supply conversion mode. Specifications Conditions -5 ℃ -40 ℃; RH <80% Power Supply AC 220V ± 10% High voltage output 1000V-2200V, every step 200V ... -
OEM Best Capacitor Tan Delta Factories – Variable Frequency AC Resonant Test System – HV Hipot
Features ● Small size, light weight, portable design. ● Suitable for 35kV or below cables. ● Single parts not more than 30kg, easy to carry. ● 220V or 380V single phase power supply,convenient for on-site power sourcing. Specifications ● Rated output voltage: based on cable voltage, usually it is 2Uo or 3Uo. ● Output frequency: 20 -300Hz. ● Resonant voltage waveform: sine wave, THD ≤ 1%. ● Full load working time: continuous working time 60mins. ● Quality factor: max. load ≥ 20. ● Frequency adjustment: fineness 0.1Hz, instability ≤ 0.01%. ● Power supply: 220V or 380V single-phase. -
OEM Best distribution transformer testing Manufacturers – GDPD-414 Portable Partial Discharge Detector – HV Hipot
Main unit UHF sensor, round type, suitable for GIS UHF sensor, rectangle type, suitable for power cable, transformer, switchgear HFCT, suitable for power cable, transformer TEV sensor, suitable for switchgear Ultrasonic sensor, suitable for transformers, switchgear Above pictures are only for reference first. The GDPD-414 Portable (GDPD-414H handheld) Partial Discharge Detector adopts smart quick intelligent power test system (Soft No. 1010215, trademark registration number 14684781 (14684481)). It can flexibly configure various sensors according to different products to be tested. TEV, ultrasonic and HFCT are suitable for partial discharge detection of high-voltage switchgear and ring network cabinet; Ultrasonic and UHF are suitable for detecting G... -
OEM Best Current Transformer Metering Factory – GDHG-106B CT/PT Analyzer – HV Hipot
Features ● Finish all testing items by itself, no need to connect auxiliary equipment. ● Intelligent controller is adopted. ● Built-in printer, to print results easily. ● Large screen LCD, graphically display. ● Auto display excitation knee point value, 5% and 10% error curve. ● Save 3000 groups data and it is not lost after power down. ● With USB port. The data can be saved in USB disk and read by PC (WORD format file). ● Portable design, suitable for on-site test. ● Engineering plastic box with damping, strong and reliable. Specifications Main functions CT (protection type, metering type) PT Voltage current characteristic curve (excitation characteristic) Voltage current characteristic curve (excitation characteristic) Auto calculate knee point value Auto calculate knee p... -
OEM Best Resistance tester price Exporters – GD3127 Series High Voltage Insulation Resistance Tester – HV Hipot
General Information GD3127 Series Insulation Resistance Tester is widely used in maintenance of electrical equipment in transformer substation, power plant, etc. It is suitable for carrying out measurement of insulation resistance(IR), polarization index(PI), absorption ratio (DAR), ramp(RAMP), filter(FR, 10s, 20s, 30s, 40s 4 choices), voltage(V), current(nA) of all kinds of high voltage equipment, including switchgear, transformers, reactors, capacitors, motors, generators and cables, etc. GD3127 Series is the perfect test tool for early identification and discovery of preventive or predictive maintenance plans for potential equipment failures. It is of great significance to ensure product quality and the safety of people and equipment in operation. The insulation performance of ele...