-
China High Quality High Voltage Instruments Factory – GDZRC series DC Winding Resistance Tester GDZRC-40A – HV Hipot
Features ● Four leads measurement to ensure measuring accuracy. ● Program-controlled current source to increase measuring speed. ● Auto discharge and discharge indication function, to ensure safety and availability. ● LCD screen and Built-in Printer. Specifications Items Specifications Remark Testing current 2.5A 5A 10A 20A 40A Measurement range 2.5A:10mΩ-8Ω 5A: 1mΩ-4Ω 10A: 1mΩ-2Ω 20A: 1mΩ-1Ω 40A:1mΩ-500mΩ Accuracy ±0.2% of full range ±2digit Data storage 255pcs Display LCD screen 4 1/2 digit Max.resolution 0.1μΩ Power supply AC 220V±22V, 50Hz±2 Hz Fuse 5A Max.power consumption 1200W Testing current is 10A Working environment Temperature: 0-40℃, Relative humidity: ≤80% Dimension 200*400*280mm Weight About 32kg -
OEM Best energy meter calibration Factories – GDDO-20C AC/DC Electric Meter Calibration Device – HV Hipot
General Information GDDO-20C AC/DC Electric Meter Calibration Device is used to detect basic error of various power frequency electric instruments in power systems, including voltmeter, ammeter, wattmeter, ohmmeter, single phase & three phase AC energy meters (optional) and basic error of DC volt-meter and ammeter. For meter’s part, it takes high precision power frequency AC collector as core technology, which consists of digital signal processor (DSP) and 16-digit high speed analog-digital converter; For signal source, it uses DSP and 16-digit high speed analog-digital converter to form signal source that produces sine wave signal and distortion wave signal. Features ● Accuracy class of 0.05. When AC voltage, AC current and active power are measured, the device is equip... -
OEM Best Impulse Voltage Test System Supplier – GDZRC-40U (GDZRC-50U) DC Winding Resistance Tester – HV Hipot
GDZRC-40U (GDZRC-50U) DC Winding Resistance Tester is designed to measure DC resistance of inductive devices, such as transformers and power inductors. It has features of fast measurement, small size, light weight, large output current, perfect protection functions, good repeat-ability, good anti-interference ability, high accuracy, which make it an ideal equipment for measuring DC resistance of transformer winding and high inductive equipment. Features ● Controlled by high-speed single chip microcomputer, highly automatic and easy to operate. ● Adopts the new power supply technology with multiple current steps and wide measurement range, which is suitable for DC resistance measurement of large and medium-sized transformers. ● Perfect protection functions, able to protect the instrum... -
OEM Best Capacitor Bank Price Factory – Insulation Materials Hipot Test Set GDJS-65 – HV Hipot
GDJS-65 Insulation Gloves Test Set It is used to test insulation performance for insulation gloves, boots, mats, hats, rod, Electroscope etc. It can test 6pcs insulation gloves/boots at the same time, also 5pcs insulation rods. Features Manual control unit ● Digital and real time display HV voltage, LV current, 6-way leak current and time. ● With leak current meter and over-current protection meter. ● With movable control unit, easy wiring and testing. ● Manual control, safety and reliability. ● With zero, power, operation, timing indicators. ● With over-current protection, zero-start protection, sound and light alarm, power protected switch. ● New type timer, broader timing range.(1s-99h). Other features ● HV source is oil immersed type testing transformer.(dry type and SF6 gas t... -
OEM Best HV insulation tester Factory – Online Insulation Monitoring Device for DC System – HV Hipot
General Information GDF-5000/OL Online Insulation Monitoring Device for DC System is used for real-time online monitoring of insulation status of DC bus and branch. This device adopts the detection method of DC balanced resistance. It does not produce any AC or DC interference signal to busbar, and will not cause the artificial insulation resistance drop. It is suitable for power plants and substations of any voltage level. GDF-5000/OL’s unique stability and anti-distributed capacitance make it more suitable for bus system under complex working conditions, standard instrument structure, compact size, convenient installation and better applicability. GDF-5000/OL has LCD display, full software function control, perfect man-machine interface, easy operation and use. Features ● ... -
China High Quality Circuit Capacitor Supplier – AC High Voltage Test Sets for GIS – HV Hipot
Applications ● Transformer ● GIS system ● SF6 switchgear ● Cables ● Bushing ● Insulator ● CT/PT ● Other capacitive devices Features ● Small temperature rises at rated load. Dry or Oil type reactors, high mechanical strength, good insulation, nice and reliable. ● Adjustable capacity of frequency control source. Strong protection, good stability. With multiple working mode, easy to operate. ● With 220V or 380V single phase power, convenient for on-site power sourcing. ● Flexible configuration. Different type reactors for optional, meet different test object requirements. Multifunctional, cost effective. Specifications ● Rated output voltage: based on different test objects. ● Output frequency: 20- 300Hz. ● Waveform: pure sine wave, THD <1.0%. ● Max. capacity: 1000kVA and belo... -
OEM Best Coupling Capacitor Use Manufacturers – VLF AC Hipot Test Set 80kV – HV Hipot
Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. AC test can be further divided into power frequency, variable frequency and 0.1Hz very low frequency test, among which the last one is highly recommended by IEC, due to its remarkable advantages. Following is a comparison for DC, Power Frequency, Variable Frequency, and 0.1Hz test. Aspects DC Power Frequency Variable Frequency 0.1Hz Equivalency poor good good good Insulation Damage strong slight slight slight Operation Safety relatively low relatively low relatively low high Wiring Difficulty complicated complicated most complicated simple Volume smallest largest large smal... -
China High Quality Energy Meter Tester Suppliers – GDYB-D24 Single Phase Energy Meter Test System – HV Hipot
Technical Specification ● Reasonable design and beautiful appearance. The device hanging table frame and the table body frame are all made of special aluminum alloy materials, and the table top is made of fire-proof and heat-resistant fiber materials. The whole device has soft colors, coordinated proportions, and reliable structure. Exquisite craftsmanship, beautiful appearance. ● Dedicated keyboard operation and PC operation coexist, easy to use. This device is equipped with a keyboard, the keyboard comes with a liquid crystal display, and the working status of the device is clear at a glance. The operation is easy and free. The PC control software has clear levels, beautiful interface, and flexible and convenient use. ● High degree of automation. When verifying the electr... -
China High Quality Underground Cable Locator Companies Exporters – GD-2136H Cable Fault Locating System – HV Hipot
GD2136H Cable Fault system is important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1. GD-2131H Impulse Generator 2. GD-2132 Cable Fault Locator 3. GD-2133 Cable Fault Tester 4. Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-2133 Cable Fault Tester, there are two locating ways: a. Low voltage pulse: If only using GD-2133, open circ... -
China High Quality Sf6 Gas Quality Analyzer Manufacturers – GDSF-411CPD SF6 Gas Comprehensive Analyzer – HV Hipot
General Information GDSF-411CPD SF6 gas comprehensive analyzer is a portable device designed to measure SF6 gas dew point, purity and decomposition product. The core component with chilled mirror method is used to test dew point, European sensor with infrared method to test SF6 gas purity and electrochemical sensor from Membrapor to test SF6 gas decomposition product. Besides, we also adopt professional hardware chips and excellent software algorithms of STMicroelectronics. Application Features Specification SF6 Humidity Measurement method Chilled mirror method (Stirling Refrigeration) Measurement range Dew point -100℃–+20℃(90s for single point measurement), error: better than ±0.2℃ Repeat-ability ± 0.1 ℃ Resolution 0.01℃ Display unit ℃, ppm, ℃ P20(convert... -
China High Quality Battery Regenerator Supplier – Battery Impdeance Tester GDBT-8612 – HV Hipot
General Information As a key component of the power system, batteries must be tested and maintained annually, quarterly or even monthly and their test data needs to be analyzed on a regular basis. Practice has proved that there is no correlation between voltage and capacity, because the voltage only reflects the surface parameters of the battery. Internationally, tests for conductance or internal resistance have been widely used in the routine maintenance of batteries to replace the previous voltage check method. Because the conductance or internal resistance is a parameter that reflects the internals of the battery, the conductance or internal resistance of the battery has been recognized as an important parameter for accurately and quickly determining the health of the battery. Th... -
China High Quality vlf test voltage Manufacturers – GDPD-3000C Portable Partial Discharge Detector – HV Hipot
GDPD-3000C Portable Ultrasonic Partial Discharge Detector uses advanced cloud computing and automatic modeling technology to achieve the partial discharge signal measurement, recording, transmission, storage, analysis and exchange, providing powerful technical support for on-site measurement of partial discharge. The measurement personnel collect the partial discharge information by using GDPD-3000C, and the cloud computing can be used to intelligently diagnose the insulation state of detection equipment in real time. Specification Hardware ● Processor: high performance intelligent processor. ● Screen: 4.3inch Touch Screen. ● Operation keys: PVE film keyboard. ● Interface: ● 3.5mm stereo headphone interface ● DC LV current charging interface ● USB 2.0 3G wireless network in...