-
China High Quality Digital Micro Ohm Meter Supplier – GDHL-100B Contact Resistance Tester (Microhm Meter) – HV Hipot
Description The performance of the conductive circuit of the circuit breaker is important to ensure the safe operation of the switch. The pros and cons of the conductive performance can be reflected by the size of the resistance of the conductive loop. Therefore, the IEC standard and the manufacturer have stipulated that the loop resistance should be measured, and there are clear specifications for the loop resistance of various types of switches. The loop resistance tester is a testing instrument meets the requirements of GB50150-2006 and DL / T 845.4-2004 regulations. It is widely applicable to the measurement of contact resistance, loop resistance, cable, wire, and weld contact resistance of various electrical switches. Application ● High,middle and low voltage circuit breakers... -
China High Quality Gas Detector Supplier Manufacturer – GDWS-311RC SF6 Gas Dew Point Tester – HV Hipot
General Information GDWS-311RC is ideal instrument to test dew point of SF6 gas. The core component is DRYCAP series sensors produced by Finland Vaisala company. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of gas moisture test instrument. Application ● Moisture monitoring of SF6 gas electrical equipment for electric power ● SF6 gas cylinder gas quality test ● High purity gas manufacturing ● Semiconductor industry dry gas supply ● Research and development use ● Clean room/dry house monitoring ● Metal heat treatment site and laboratory industrial gas humidity detection, such as air, CO2, N2, H2, O2, SF6, He, Ar and other inert gases. Features ● Better than ±2℃ measurement accuracy. ● All gas path are ... -
OEM Best Handheld Sf6 Gas Leak Detector Factory – GDSF-311WP SF6 Dew Point and Purity Tester – HV Hipot
General Information GDSF-311WP is ideal instrument when it is necessary to test water content and purity of SF6 gas. The core component is DRYCAP series sensors produced by Finland Vaisala company. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of gas moisture test instrument. Application ● Moisture monitoring of SF6 gas electrical equipment for electric power ● SF6 gas cylinder gas quality test ● High purity gas manufacturing ● Semiconductor industry dry gas supply ● Research and development use ● Clean room/dry house monitoring ● Metal heat treatment site and laboratory industrial gas humidity detection, such as air, CO2, N2, H2, O2, SF6, He, Ar and other inert gases. Features Specification SF6 ... -
OEM Best Online Partial Discharge Testing Supplier – GDJF-2008 Partial Discharge Analyzer – HV Hipot
GDJF-2008 Partial Discharge Detector is measuring partial discharge for the products such as transformers, mutual inductors, HV switches, zinc monoxide arresters and power cables. It also can make type tests and monitor insulation operation. This type has the advantages of high sensitivity, wide range of capacitance, being well equipped for input unit impedance detecting and more variants of frequency bands (9 in all). After proper setting, the discharge impulse amount can be read directly. The indicating and digital meters are shown simultaneously. This detector is widely applied in power stations, manufacturers, and institutions. Use Condition ● Ambient temperature: 0-40℃±2℃. ● Relative humidity: ≤80% ● Power supply: 220V±10%, 50HZ. ● No violent vibration and mechanical shock. ● Th... -
China High Quality Capacitor Discharge Device Manufacturers – AC Dielectric Test Equipment with manual control unit GDYD-M – HV Hipot
Application AC Hipot testing is the effective and direct way to test insulation strength for electric equipment, apparatus, or machines. It checks dangerous flaws which assure electric equipment continuous working. Typical applications include testing of transformers, switchgear, cables, capacitors, aerial motors platforms, hot sticks bucket bricks, vacuum bottles and other related equipment like vacuum interrupters, blankets, ropes, gloves, hydraulics hose, instruments transformers generators. Features ● Pointer display panel mounted controls & indicators with easy-to-read legend. ● Monitoring high voltage side voltage, low voltage side current and indicator of zero, power, working start, timing. ● Over-current protection, zero-starting protection, sound, and light alarm. ● C... -
OEM Best protection relay tester price Factory – GDJB-802 3 Phase Secondary Current Injection Relay Test Set – HV Hipot
General Information GDJB-802 3 Phase Secondary Current Injection Relay Protection Test Device plays a key role in operating electricity power systems reliably and safely. It can automatically judge over-current, over-voltage, overload, short circuit, high temperature, abnormal data and warning prompts for misoperation. In addition to the verification of various relays (such as current, voltage, inverse time, power direction, impedance, differential, low cycle, synchronization, frequency, DC, intermediate, time, etc.) and microcomputer protection, it can also simulate single-phase to Three-phase transient, permanent, and transitional faults are tested for the entire set. It can also complete various large-scale and complex calibration tasks with a high degree of automation, can automa... -
OEM Best Circuit Breaker Test Equipment Manufacturer – GDHL-100HS 100A Handheld Contact Resistance Tester – HV Hipot
General Information The product is mainly used for the contact resistance of switch contacts and other micro-ohm resistance measurement, and the test speed is fast and the accuracy is high. This handheld contact resistance tester is an innovative product that is compact, hand-held, battery powered and easy to carry. Features ● Maximum output current is 100A, two current levels are selectable ● Built-in large capacity lithium battery, it can perform more than 600 tests on one charge. ● The test is simple, the operation is convenient, and it can work continuously for more than 8 hours. ● In the 100A test, the longest test time can be up to 60 seconds, which can meet various usage scenarios on site. ● Wide range, high precision, up to 10mΩ at 100A. ● With complete protection functio... -
China High Quality Primary Current Injection Test Set Manufacturers Factory – GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot
Adoption of Standard ● DL/T 596-2005 “Procedure Test Procedures for Electrical Equipment” ● GB1094.1-GB1094.6-96 “Shell protection level” ● GB2900 “Electrical Terminology” ● GB/T16927.1~2-1997 “High Voltage Test Technology” ● GB4793-1984 “Safety Requirements for Electronic Measuring Instruments” ● GB191 “Package Storage and Transportation Mark” ● GB/T.311-1997 “Insulation and coordination of high voltage power transmission and transformation equipment” Features ● Using high conductivity copper as the output electrode, the contact surface is large and the flow capacity is strong. ● Brushed aluminum plate with a new process, simple and eye-catching, wear-resistant and pollution-resistant. ● The all-... -
OEM Best Series Capacitance Voltmeter Suppliers – AC High Voltage Test Sets for GIS – HV Hipot
Applications ● Transformer ● GIS system ● SF6 switchgear ● Cables ● Bushing ● Insulator ● CT/PT ● Other capacitive devices Features ● Small temperature rises at rated load. Dry or Oil type reactors, high mechanical strength, good insulation, nice and reliable. ● Adjustable capacity of frequency control source. Strong protection, good stability. With multiple working mode, easy to operate. ● With 220V or 380V single phase power, convenient for on-site power sourcing. ● Flexible configuration. Different type reactors for optional, meet different test object requirements. Multifunctional, cost effective. Specifications ● Rated output voltage: based on different test objects. ● Output frequency: 20- 300Hz. ● Waveform: pure sine wave, THD <1.0%. ● Max. capacity: 1000kVA and belo... -
OEM Best pd transformer Exporters – Partial Discharge Online Monitoring System of Generators – HV Hipot
General Information Generally, partial discharge occurs at a position where the properties of the dielectric material are not uniform. At these locations, the local electric field strength is enhanced, and local electric field strength is too large, resulting in local breakdown. This partial breakdown is not the total breakdown of the insulating structure. Partial discharges typically require a certain amount of gas space to develop, such as gas voids inside the insulation, adjacent conductors, or insulating interfaces. When the local field strength exceeds the dielectric strength of the insulating material, a partial discharge occurs, causing many partial discharge pulses to occur during one cycle of applying the voltage. The amount of discharge delivered is closely related to the n... -
OEM Best Simulate Lightning Impulse Suppliers – GDCY-20B 20kV Impulse Voltage Tester (Basic Type) – HV Hipot
GDCY-12B Programmable Automatic Impulse Voltage Tester is mainly based on TB/T 2653, GB/T 17627, GB/T 16927, GB14048, GB7251, GB/T 16935, IEC 61730, GB4706, GB3048, JB/T 7083 and other standard requirements. It is mainly used for safety performance (dielectric performance) detection of low-voltage electrical appliances, high and low voltage switches, solar energy, electricity meters, relays, leakage protectors, etc. The impulse output can be controlled by computer, and the test report can be printed and generated. (Picture only for reference first.) Features ● Manual/automatic/programmable mode: Manual mode adjusts impulse voltage manually by adjusting knob; Automatic mode adjusts impulse voltage automatically by the system; Programmable mode uses computer to control impulse vo... -
OEM Best megger tester for sale Exporters – Dielectric Loss Tester for Live Capacitive Equipment GDDJ-HVC – HV Hipot
General Information There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. If the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be found in ...