Featured

  • China High Quality Cap Coupling Supplier –  AC Inductance Resonance Test System for CVT – HV Hipot

    China High Quality Cap Coupling Supplier – AC Inductance Resonance Test System for CVT – HV Hipot

    GDTL AC Resonant Test System for CVT is series resonance with power frequency specially for CVT. It is smaller size and more lighter weight than traditional device, meet various CVT inspection requirements of voltage with 35kV, 66kV, 110kV, 220kV, 330kV, 500kV. According to customer’s requirement, the reactor can be divided into fixed and adjustable reactor. Features ● Small size, light weight, simple wiring. ● Dry or Oil type reactor, high mechanical strength, good insulation, high reliability. ● Large capacity margin, good output waveform, easy to operate. ● Fully protection function: zero protection, over-voltage protection, over-current protect functions.
  • OEM Best grounding resistance tester Manufacturer –  GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot

    OEM Best grounding resistance tester Manufacturer – GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot

    General Information GD3126A  (GD3126B) Insulation Resistance Tester is widely used in maintenance of electrical equipment in transformer substation, power plant, etc. It is suitable for carrying out measurement of insulation resistance (IR), absorption ratio (DAR), polarization index (PI), leakage current (Ix) and absorption capacitance (Cx) of all kinds of high voltage equipment, including switchgear, transformers, reactors, capacitors, motors, generators and cables, etc. Features ● Adopts microcomputer control, menu operation and large LCD screen dot matrix display with stable performance. ● Strong anti-interference ability, suitable for measuring in strong electromagnetic interference environment. ● Large capacity, can meet the requirements of high voltage, high resistance, lar...
  • China High Quality electrical earthing Manufacturers –  GD3127 Series High Voltage Insulation Resistance Tester   – HV Hipot

    China High Quality electrical earthing Manufacturers – GD3127 Series High Voltage Insulation Resistance Tester – HV Hipot

    General Information GD3127 Series Insulation Resistance Tester is widely used in maintenance of electrical equipment in transformer substation, power plant, etc. It is suitable for carrying out measurement of insulation resistance(IR), polarization index(PI), absorption ratio (DAR), ramp(RAMP), filter(FR, 10s, 20s, 30s, 40s 4 choices), voltage(V), current(nA) of all kinds of high voltage equipment, including switchgear, transformers, reactors, capacitors, motors, generators and cables, etc. GD3127 Series is the perfect test tool for early identification and discovery of preventive or predictive maintenance plans for potential equipment failures. It is of great significance to ensure product quality and the safety of people and equipment in operation. The insulation performance of ele...
  • OEM Best How Can Calculate Transformer Full Load Current Supplier –  GDHG-201P CT/PT Analyzer – HV Hipot

    OEM Best How Can Calculate Transformer Full Load Current Supplier – GDHG-201P CT/PT Analyzer – HV Hipot

    Features ● Full function and can satisfy all kinds of CT (protection CT, measuring CT, TP) test requirements, such as excitation characteristic test, turn ratio, polarity, secondary winding resistance, secondary burden, ratio error, angular difference and etc. Also can used to test excitation characteristic, turn ratio, polarity, secondary winding resistance, ratio error, angular difference and etc of all kinds of PT. ● Field verification of CT does not require standard current transformers, current injector, load bank, voltage regulating controller and large current cables. Very simple test wiring and operation are used to realize the current transformer verification, which greatly reduces the work intensity and improves the work efficiency, and facilitates the field verification of...
  • China High Quality ultrasonic flaw detectors Exporters –  GDYZ-301 Zinc Oxide Surge Arrester Tester  – HV Hipot

    China High Quality ultrasonic flaw detectors Exporters – GDYZ-301 Zinc Oxide Surge Arrester Tester – HV Hipot

    Features 1. 800*480 color LCD touch screen, with high speed thermal printer. 2. Graphic display, intuitive interface, easy to operate and use on-site. 3. Long distance wireless transmission. PT signal wireless transmission distance more than 400m (2000m can be customized). 4. Suitable for testing in various situation such as lightning arrester with or without electricity, laboratory. 5. Test three phase current, three phase voltage at the same time, more efficient. 6. No strong electricity inside, voltage not more than 12V. Current and voltage sensors are completely isolated, safe and reliable. 7. Support various voltage sampling: 1. Wired; 2 wireless; 3. Non-voltage; A. Wire: digital signal transmission with cable which the signal is from PT metering winding; B. Wireless: digital s...
  • China High Quality Discharge Cable Factory –  GDPD-3000C Portable Partial Discharge Detector – HV Hipot

    China High Quality Discharge Cable Factory – GDPD-3000C Portable Partial Discharge Detector – HV Hipot

    GDPD-3000C Portable Ultrasonic Partial Discharge Detector uses advanced cloud computing and automatic modeling technology to achieve the partial discharge signal measurement, recording, transmission, storage, analysis and exchange, providing powerful technical support for on-site measurement of partial discharge. The measurement personnel collect the partial discharge information by using GDPD-3000C, and the cloud computing can be used to intelligently diagnose the insulation state of detection equipment in real time. Specification Hardware ● Processor: high performance intelligent processor. ● Screen: 4.3inch Touch Screen. ● Operation keys: PVE film keyboard. ● Interface: ● 3.5mm stereo headphone interface ● DC LV current charging interface ● USB 2.0 3G wireless network in...
  • China High Quality Hv Surge Generators Suppliers –  GDCL-20kV/10kA Impulse Combination Wave Test System Technical Solution – HV Hipot

    China High Quality Hv Surge Generators Suppliers – GDCL-20kV/10kA Impulse Combination Wave Test System Technical Solution – HV Hipot

    Application The equipment is according to combination wave testing requirement of the low-voltage power distribution system SPD II product, enable to generate impulse voltage (1.2/50μs) and impulse current (8/20μs), is used for grade III test and limiting voltage test of SPD and components. It is also used for impulse current test and residual voltage test of the MOV valve plate, unit and surge protective device(SPD), or used in other scientific research experiments. The device uses touch screen and PLC control technology, and the main performance meets the needs of domestic and foreign SPD products and their components for various combination wave testing. Standards ● GB 18802.1-2012 GB 18802.1-2012 Surge protective devices connected to low-voltage power distribution systems Par...
  • China High Quality Wire resistance test Manufacturer –  GDCR3000 Digital Earth Resistance Tester – HV Hipot

    China High Quality Wire resistance test Manufacturer – GDCR3000 Digital Earth Resistance Tester – HV Hipot

    General Information GDCR3000 Digital Earth Resistance Tester is specially designed and manufactured for field measurement, adopting the latest digital and micro-processing technology, 3-pole or 2-pole method for earth resistance measurement, with a unique function of wire resistance verification, anti-interference capability and the ability to adapt to the environment, to ensure high precision, high stability and reliability for prolonged measure, which is widely used in electric power, telecommunications, meteorology, oil field, construction, lightning protection, industrial electrical equipment and other earth ground resistance measurement. Measurement range & Accuracy Measurement function Range Accuracy Resolution Earth resistance 0.01Ω~20Ω ±2%rdg ±3dgt (Auxiliary ear...
  • China High Quality relay tester price Exporters –  GDJB-802 3 Phase Secondary Current Injection Relay Test Set – HV Hipot

    China High Quality relay tester price Exporters – GDJB-802 3 Phase Secondary Current Injection Relay Test Set – HV Hipot

    General Information GDJB-802 3 Phase Secondary Current Injection Relay Protection Test Device plays a key role in operating electricity power systems reliably and safely. It can automatically judge over-current, over-voltage, overload, short circuit, high temperature, abnormal data and warning prompts for misoperation. In addition to the verification of various relays (such as current, voltage, inverse time, power direction, impedance, differential, low cycle, synchronization, frequency, DC, intermediate, time, etc.) and microcomputer protection, it can also simulate single-phase to Three-phase transient, permanent, and transitional faults are tested for the entire set. It can also complete various large-scale and complex calibration tasks with a high degree of automation, can automa...
  • China High Quality Transformer Capacitance Suppliers –  High voltage divider GDFR-D1 – HV Hipot

    China High Quality Transformer Capacitance Suppliers – High voltage divider GDFR-D1 – HV Hipot

    GDFR-D1 series AC/DC Voltage Meter GDFR-D1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. The digital meter and divider are equipped in one unit.  Features ● Balance type equal potential shield structure. ● Fully-sealed insulation cylinder with internal excellent components. ● High accuracy and linearity, good stability and anti-interference ability. ● With good filling materials, which make the structure smaller and weight lighter, and minimize internal partial discharge. ● Small size, light weight, easy to carry in the field work. ● Inner shield anti-interference system. ● The voltage ratio can be customized, suitable for calibration. ● External voltage meter can be connected. Technical Specifications Model No. GDFR-D1-50 GDFR-D1-100 G...
  • China High Quality Primary Current Injection Test Germany Factory –  GDSL-BX-100 Primary Current Injection Test Set – HV Hipot

    China High Quality Primary Current Injection Test Germany Factory – GDSL-BX-100 Primary Current Injection Test Set – HV Hipot

    Features Specifications ● Power supply: AC 220V 50Hz. ● Output power: 3kVA. ● Output current: 500A in series,1000A in parallel. ● Output voltage: 6V in series, 3V in parallel. ● Current can be adjusted smoothly and continuously. The accuracy is 1.0%. ● Output current is standard sine wave, waveform distortion is less than 5%. ● Output current: RMS continuous adjustable. ● Duty Cycle: 5mins ON, 10mins OFF. Accessories Main unit 1 piece Connection cable 1 piece 2m Output cable 2 pcs 1000A  Ground cable 1 piece Power cable 1 piece User’s guide 1 piece Factory test report 1 piece
  • China High Quality Multi Gas Detector Price Manufacturers –  GDWG-V SF6 Gas Leak Detector (IR type, Double display) – HV Hipot

    China High Quality Multi Gas Detector Price Manufacturers – GDWG-V SF6 Gas Leak Detector (IR type, Double display) – HV Hipot

    Product Description GDWG-V SF6 Gas Leak Detector is infrared red type leak detector (NDIR technology) with double display. It is color INCELL TFT display and real-time shows SF6 concentration. It rapidly detects SF6 breaker, GIS leakage point and yearly leakage rate qualitatively and quantitatively. It is a good device suitable for power supply department, installation and overhaul unit, power test institute. Application ● High Voltage Switch Equipment ● Rotor vane of helicopter ● Gas transmission system ● To detect fire extinguisher ● Ventilation efficiency research of Buildings ● To detect danger Advantages ● No radiation. ● No need to replace high pressure high pure argon gas regularly. ● No need to approach high pressure gas. ● No need to replace sensors regularl...

Send your message to us:

Write your message here and send it to us