Featured

  • OEM Best pd calibrator Suppliers –  GD-610C Remote Ultrasonic Partial Discharge Detector – HV Hipot

    OEM Best pd calibrator Suppliers – GD-610C Remote Ultrasonic Partial Discharge Detector – HV Hipot

    Partial discharge is one of the common reasons of medium and high voltage equipment and cable insulation failures. Partial discharge testing can detect harmful defects and help identify potential future failures. The GD-610C remote ultrasonic partial discharge detector uses an ultrasonic spectrum probe (sensor) to collect ultrasonic signals and analyze the signal to diagnose the charged detection, it is a diagnosis device for the accident of the distribution line. The device determines the line position and the fault type of the faulty hidden line when it is live. After collecting the ultrasonic abnormal signal, it transmits signals to the host, converts it into an audible sound signal and waveform, and finally diagnoses the type of the hidden danger and grade by the analysis software. ...
  • China High Quality Earth Fault Loop Impedance Test Manufacturer –  GDSL-BX-100 Primary Current Injection Test Set – HV Hipot

    China High Quality Earth Fault Loop Impedance Test Manufacturer – GDSL-BX-100 Primary Current Injection Test Set – HV Hipot

    Features Specifications ● Power supply: AC 220V 50Hz. ● Output power: 3kVA. ● Output current: 500A in series,1000A in parallel. ● Output voltage: 6V in series, 3V in parallel. ● Current can be adjusted smoothly and continuously. The accuracy is 1.0%. ● Output current is standard sine wave, waveform distortion is less than 5%. ● Output current: RMS continuous adjustable. ● Duty Cycle: 5mins ON, 10mins OFF. Accessories Main unit 1 piece Connection cable 1 piece 2m Output cable 2 pcs 1000A  Ground cable 1 piece Power cable 1 piece User’s guide 1 piece Factory test report 1 piece
  • China High Quality Primary Injection Tester Suppliers –  GDSL-BX-100 Primary Current Injection Test Set – HV Hipot

    China High Quality Primary Injection Tester Suppliers – GDSL-BX-100 Primary Current Injection Test Set – HV Hipot

    Features Specifications ● Power supply: AC 220V 50Hz. ● Output power: 3kVA. ● Output current: 500A in series,1000A in parallel. ● Output voltage: 6V in series, 3V in parallel. ● Current can be adjusted smoothly and continuously. The accuracy is 1.0%. ● Output current is standard sine wave, waveform distortion is less than 5%. ● Output current: RMS continuous adjustable. ● Duty Cycle: 5mins ON, 10mins OFF. Accessories Main unit 1 piece Connection cable 1 piece 2m Output cable 2 pcs 1000A  Ground cable 1 piece Power cable 1 piece User’s guide 1 piece Factory test report 1 piece
  • OEM Best meter test Factories –  GDPQ-300E Power Quality Analyzer – HV Hipot

    OEM Best meter test Factories – GDPQ-300E Power Quality Analyzer – HV Hipot

    Introduction GDPQ-300E Power Quality Analyzer is a portable device of testing and analyzing power system operation quality. It monitors and collects data in long running time, also provides harmonic analysis and power quality analysis. Meanwhile, it equips with data analysis software, by which the measure data can be uploaded to PC.   Features ● ARM and DSP, 16M byte memory. ● Touch screen, more easy and convenient. ● Data measuring and saving, can be uploaded to PC. ● Module structure, reasonable design and reliable operation. ● Easy and convenient software upgrading. ● Detailed analysis of measure data by power quality data analysis software in PC. Basic functions Meter detection functions No Items Description 1 Voltage/Current/Frequency It can measure three-phase volt...
  • China High Quality Testing Required For Power Circuit Breakers Supplier –  GDSL-BX-100 Primary Current Injection Test Set – HV Hipot

    China High Quality Testing Required For Power Circuit Breakers Supplier – GDSL-BX-100 Primary Current Injection Test Set – HV Hipot

    Features Specifications ● Power supply: AC 220V 50Hz. ● Output power: 3kVA. ● Output current: 500A in series,1000A in parallel. ● Output voltage: 6V in series, 3V in parallel. ● Current can be adjusted smoothly and continuously. The accuracy is 1.0%. ● Output current is standard sine wave, waveform distortion is less than 5%. ● Output current: RMS continuous adjustable. ● Duty Cycle: 5mins ON, 10mins OFF. Accessories Main unit 1 piece Connection cable 1 piece 2m Output cable 2 pcs 1000A  Ground cable 1 piece Power cable 1 piece User’s guide 1 piece Factory test report 1 piece
  • OEM Best High Impedance Faults Factories –  GDCF-900T Vehicle Mounted Cable Fault Locating System – HV Hipot

    OEM Best High Impedance Faults Factories – GDCF-900T Vehicle Mounted Cable Fault Locating System – HV Hipot

    Vehicle Mounted Cable Fault Locator system is used for Cable Fault conditioning (burn-down), Pre-Location, Route Location, Pin-pointing & Testing of HV & LV cables of different types&sizes. The set is suitable to carrying out the above-mentioned multifunction on power cables of various voltage levels mainly 33KV, 11KV, 415V and control cables with 1.1 KV grade. The set shall be used for cable types namely XLPE, PVC, PILC with Al / Cu conductor. The cables are laid underground (under plain earth, trenches, or RCC surface, Horizontal Drilling in HDD Pipe), above ground or partly under & partly above ground with maximum cable length around 25Km. The cable fault locator is suitable for fault locating and pinpointing the following types of cable faults. ● High resistance ● L...
  • OEM Best Insulation Resistance Tester Manufacturers Suppliers –  GDHL-100B Contact Resistance Tester (Microhm Meter) – HV Hipot

    OEM Best Insulation Resistance Tester Manufacturers Suppliers – GDHL-100B Contact Resistance Tester (Microhm Meter) – HV Hipot

    Description The performance of the conductive circuit of the circuit breaker is important to ensure the safe operation of the switch. The pros and cons of the conductive performance can be reflected by the size of the resistance of the conductive loop. Therefore, the IEC standard and the manufacturer have stipulated that the loop resistance should be measured, and there are clear specifications for the loop resistance of various types of switches. The loop resistance tester is a testing instrument meets the requirements of GB50150-2006 and DL / T 845.4-2004 regulations. It is widely applicable to the measurement of contact resistance, loop resistance, cable, wire, and weld contact resistance of various electrical switches. Application ● High,middle and low voltage circuit breakers...
  • OEM Best ınsulatıon test Manufacturers –  GD3127 Series High Voltage Insulation Resistance Tester   – HV Hipot

    OEM Best ınsulatıon test Manufacturers – GD3127 Series High Voltage Insulation Resistance Tester – HV Hipot

    General Information GD3127 Series Insulation Resistance Tester is widely used in maintenance of electrical equipment in transformer substation, power plant, etc. It is suitable for carrying out measurement of insulation resistance(IR), polarization index(PI), absorption ratio (DAR), ramp(RAMP), filter(FR, 10s, 20s, 30s, 40s 4 choices), voltage(V), current(nA) of all kinds of high voltage equipment, including switchgear, transformers, reactors, capacitors, motors, generators and cables, etc. GD3127 Series is the perfect test tool for early identification and discovery of preventive or predictive maintenance plans for potential equipment failures. It is of great significance to ensure product quality and the safety of people and equipment in operation. The insulation performance of ele...
  • OEM Best Portable Gas Detector Suppliers –  GDPDS-341 SF6 Electrical Insulation State Comprehensive Analyzer – HV Hipot

    OEM Best Portable Gas Detector Suppliers – GDPDS-341 SF6 Electrical Insulation State Comprehensive Analyzer – HV Hipot

    General Information At present, the UHV voltage level of 110KV and above uses SF6 gas-insulated enclosed GIS as the main primary equipment of the substation, the evaluation of GIS internal insulation status is mainly achieved by partial discharge detection method and SF6 gas chemical analysis method at home and abroad. When partial discharge occurs in the early stage of insulation degradation inside the GIS, it will cause serious safety hazards to its safe operation. The detection methods of partial discharge mainly include three methods: ultra-high frequency partial discharge test, ultrasonic partial discharge test, and chemical detection of SF6 gas composition. At present, there are separate devices for these types of test methods on the market. For on-site GIS partial discharge li...
  • OEM Best ac dc voltage tester, Supplier –  Turn-to-turn Surge Tester – HV Hipot

    OEM Best ac dc voltage tester, Supplier – Turn-to-turn Surge Tester – HV Hipot

    GDZJ-10S Turn to Turn Surge Withstand Testerh GDZJ-10S is used to test turn-to-turn insulation strength of single phase motor, 3-phase motor, Micro motor, Special motor, electrical motor, transformer (including switching mode power supply transformer), relay and winding electrical equipment. Features It can detect below faults: ● Turn-to-turn Insulation breakdown ● Corona discharge ● Winding connection mistake ● Winding disconnection ● Turn-to-turn difference ● Short-circuit between inter-phase, winding phase, or iron core Specifications ● Peak voltage: 500-10kV continuous adjustment ● Peak error: ≤ 5%(1kV-5kV) ● Waveform rising time: 0.5μS or 0.2μS ● Power supply: 220V±10%, 50Hz ● Power consumption: ≤ 800 W ● Dimension: 900*460*550mm ● Weight: about 70kg Important Tips GDZJ...
  • China High Quality Primary Current Injection Test Kit Price Manufacturer –  GDKC-15 Series Circuit Breaker Analyzer 2020.12 – HV Hipot

    China High Quality Primary Current Injection Test Kit Price Manufacturer – GDKC-15 Series Circuit Breaker Analyzer 2020.12 – HV Hipot

    General Information High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-15 Series is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy.  GDKC-15 Series   GDKC-15A GDKC-15B GDKC-15C GDKC-15D GDKC-15E GDKC-15F GDKC-15G GDKC-15H Metal contact 12 12 12 12 12 12 12 12 Closing resistance   6 6 6 6 6 6 6 Graphite contact       3 3 3 3 6 Double-ended grounding         3 3 3 6 Dynamic resistance(Pre-insertion resistor) 1 1 3 3   3 3 6 Static resistance 1 1 3 3   3 3 6 Ground resistance             3 6 Features ● It is suitable for the mechanical test of all types of SF6 switches, GIS combination appliances, vacuum switches and oil switches. ● Strong an...
  • China High Quality Dc Capacitor Supplier –  DC High Voltage Generator GDZG-300 – HV Hipot

    China High Quality Dc Capacitor Supplier – DC High Voltage Generator GDZG-300 – HV Hipot

    Features ● Simple operation and complete function, easy for wild work. ● Higher voltage stability, smaller ripple coefficient. ● More reliable and stable, continuous short-circuit discharge directly to ground. ● Intelligent grounding protection and alarm function. High precision, accurate measurement, digital display of voltmeter and ammeter, with voltage resolution 0.1kV, and current 0.1uA. ● High stability of voltage regulation, smooth voltage boosting process, high adjustable precision, with coarse and fine adjustment functions. Accuracy of voltage regulation better than 0.1%, voltage and current measurement error is less than 1.0%, ripple factor better than 0.5%. ● With function of high-accuracy 75%VDC-1mA, more convenient for zinc oxide lighting arrester DC testing. ● HV booste...

Send your message to us: