-
OEM Best Electrical Wire Tester Supplier – GDCF-900T Vehicle Mounted Cable Fault Locating System – HV Hipot
Vehicle Mounted Cable Fault Locator system is used for Cable Fault conditioning (burn-down), Pre-Location, Route Location, Pin-pointing & Testing of HV & LV cables of different types&sizes. The set is suitable to carrying out the above-mentioned multifunction on power cables of various voltage levels mainly 33KV, 11KV, 415V and control cables with 1.1 KV grade. The set shall be used for cable types namely XLPE, PVC, PILC with Al / Cu conductor. The cables are laid underground (under plain earth, trenches, or RCC surface, Horizontal Drilling in HDD Pipe), above ground or partly under & partly above ground with maximum cable length around 25Km. The cable fault locator is suitable for fault locating and pinpointing the following types of cable faults. ● High resistance ● L... -
China High Quality protection relay tester price Supplier – GDJB-6000D Smart Substation Relay Protection Test System – HV Hipot
GDJB-6000D is equipped with high-performance power amplifier and based on the powerful PowerPC+X86 platform. It adopts modular design and have powerful functions, high precision, small size and light weight features. It can test the function and performance of merging unit, relay protection device, measurement and control device, intelligent terminals etc. Very suitable for power plants, substations, various scientific research units and equipment manufacturing enterprises. Features ● Smart Test Module Intelligent test template editing is supported. Test items can be randomly added during the test process and saved as reusable test project files to improve the test efficiency in the final stage of inspection and elimination. ● Automatic testing With on-site protection and digital pr... -
China High Quality Cable Route Locator Exporters – GD-2134E Cable Identifier – HV Hipot
GD-2134E is a high-performance underground metal pipeline detection system composed of signal transmitters and receivers. It can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables. It can carry out uniqueness identification with a variety of selected accessories, as well as pipe insulation damage and the search for some types of cable faults. Features ● Compass display: intuitively displays the pipeline location and left & right directions. ● Tracking true and false prompts: current direction measurement, tracking correct error prompts, eliminating line interference (some frequencies). ● Depth and current measurements, can display the signal strength historical curve. ● Fully digital high-precision sampling processing: sta... -
OEM Best Ct Analyser Price Supplier – GDHG-108A CT/PT Tester – HV Hipot
GDHG-108A CT/PT Tester supports test voltage method to test bushings CTs which installed on transformer or inside switch-gear, suitable for the laboratory and on-site detection. Itcan be easily and conveniently done voltage current characteristic, transformer ratio, ratio and phase angle error, load test items on CT/PT. Features ● Using the voltage detection principle to measure CT and PT. ● To meet the requirements of GB1207, GB1208, GB168-47 (IEC60044-1.6) and other standards. ● No external auxiliary equipment, a single machine can complete all test items. ● With high speed micro printer: real-time print the test result. ● Using intelligent controller, operation is simple. ● 5inch LCD screen display. ● Automatically given CT/PT (excitation) knee point value. ● Auto display 5% and 1... -
OEM Best Primary Current Injection Tester Türkçe Exporters – GDGK-501 DC Power Supply – HV Hipot
Features ● Using contact regulators to output voltage and rectify by rectifier bridge. ● The output voltage is continuous adjusted. ● Thermal cut-outs for short-circuit protectors at DC output. ● Small size, light weight. Specifications ● Input Voltage: AC220V±10%, 50Hz, single phase ● Capacity: 3kVA ● Output Voltage: AC 0-260V DC 0-360V ripple: 3% ● Output Current: 10A (continuous), 20A(short time) ● 24vdc, 48vdc, 110vdc, and 250vdc, 15A ● Maximum load current: 20A ● Accuracy: 1.5% of the range ● Temperature: -10℃-45℃, humidity: <80% ● Dimension: 440*340*240 mm ● Weight: 18kg Accessories Test Box 1 set Power cord 1 piece Ground wire 1 piece Test wire 6 pieces Manual 1 piece Factory test report 1 copy Packing list 1 copy -
China High Quality uhf detector Supplier – GDPD-414H Handheld Partial Discharge Detector – HV Hipot
Pictures for reference only. The GDPD-414H handheld Partial Discharge Detector adopts smart quick intelligent power test system (Soft No. 1010215, trademark registration number 14684481). It can flexibly configure various sensors according to different products to be tested. TEV, ultrasonic and HFCT are suitable for partial discharge detection of high-voltage switchgear and ring network cabinet; Ultrasonic and UHF are suitable for detecting GIS; Ultrasonic and HFCT are suitable for testing power cable. The built-in expert diagnosis system can analyze the test data and judge the discharge energy and possible parts. It is widely used in electric power and railway. Features ● Portable ABS engineering chassis. All PD detection hosts, tablets, sensors, chargers and signal cables are placed... -
China High Quality Sf6 Circuit Breaker Testing Factory – GDHL-100B Contact Resistance Tester (Microhm Meter) – HV Hipot
Description The performance of the conductive circuit of the circuit breaker is important to ensure the safe operation of the switch. The pros and cons of the conductive performance can be reflected by the size of the resistance of the conductive loop. Therefore, the IEC standard and the manufacturer have stipulated that the loop resistance should be measured, and there are clear specifications for the loop resistance of various types of switches. The loop resistance tester is a testing instrument meets the requirements of GB50150-2006 and DL / T 845.4-2004 regulations. It is widely applicable to the measurement of contact resistance, loop resistance, cable, wire, and weld contact resistance of various electrical switches. Application ● High,middle and low voltage circuit breakers... -
OEM Best Cable Fault Finder Manufacturers – GD-2136H Cable Fault Locating System – HV Hipot
GD2136H Cable Fault system is important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1. GD-2131H Impulse Generator 2. GD-2132 Cable Fault Locator 3. GD-2133 Cable Fault Tester 4. Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-2133 Cable Fault Tester, there are two locating ways: a. Low voltage pulse: If only using GD-2133, open circ... -
China High Quality Power Cable Locator Manufacturers – GD-2134A Cable Identifier – HV Hipot
The purpose of the cable identifier is to accurately identify one of the target cables from multiple cables and avoid serious accidents caused by wrong sawing of live cables. Cable identification starts from the operation of both ends of the cable, it must be ensured that the double number on both ends of the cable is accurate. GD-2134A Cable Identifier is only suitable for on-site identification of de-energized cables. It is strictly forbidden to connect the cable identifier to the running power cable! Features ● Handheld receiver automatically identify and display the results to ensure that the results of cable identification are 100% accurate. Light weight and powerful, easy to carry. ● Suitable for on-site identification of de-energized cables. ● Both transmitter and handheld re... -
OEM Best Combustion Analyser Manufacturers – GDWG-IV SF6 Gas Leak Detector(IR series) – HV Hipot
Product Description GDWG-IV SF6 Gas Leak Detector is infrared red type leak detector(NDIR technology). It is color OLED display and real-time shows SF6 concentration. It rapidly detect SF6 breaker, GIS leakage point and yearly leakage rate qualitatively and quantitatively. It’s a good device suitable for power supply department, installation and overhaul unit, power test institute. Application ● High Voltage Switch Equipment ● Rotor vane of helicopter ● Gas transmission system ● To detect fire extinguisher ● Ventilation efficiency research of Buildings ● To detect danger Advantages ● No radiation. ● No need to replace high pressure high pure argon gas regularly. ● No need to approach high pressure gas. ● No need to replace sensors regularly, cost-effective. ● Stable ... -
OEM Best Sf6 Circuit Breaker Testing Suppliers – GDSL-BX-100 Primary Current Injection Test Set – HV Hipot
Features Specifications ● Power supply: AC 220V 50Hz. ● Output power: 3kVA. ● Output current: 500A in series,1000A in parallel. ● Output voltage: 6V in series, 3V in parallel. ● Current can be adjusted smoothly and continuously. The accuracy is 1.0%. ● Output current is standard sine wave, waveform distortion is less than 5%. ● Output current: RMS continuous adjustable. ● Duty Cycle: 5mins ON, 10mins OFF. Accessories Main unit 1 piece Connection cable 1 piece 2m Output cable 2 pcs 1000A Ground cable 1 piece Power cable 1 piece User’s guide 1 piece Factory test report 1 piece -
China High Quality ground resistance testers Factories – GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot
General Information GD3126A (GD3126B) Insulation Resistance Tester is widely used in maintenance of electrical equipment in transformer substation, power plant, etc. It is suitable for carrying out measurement of insulation resistance (IR), absorption ratio (DAR), polarization index (PI), leakage current (Ix) and absorption capacitance (Cx) of all kinds of high voltage equipment, including switchgear, transformers, reactors, capacitors, motors, generators and cables, etc. Features ● Adopts microcomputer control, menu operation and large LCD screen dot matrix display with stable performance. ● Strong anti-interference ability, suitable for measuring in strong electromagnetic interference environment. ● Large capacity, can meet the requirements of high voltage, high resistance, lar...