Featured

  • China High Quality Cable Locator Price Manufacturers –  GD-2134A Cable Identifier – HV Hipot

    China High Quality Cable Locator Price Manufacturers – GD-2134A Cable Identifier – HV Hipot

    The purpose of the cable identifier is to accurately identify one of the target cables from multiple cables and avoid serious accidents caused by wrong sawing of live cables. Cable identification starts from the operation of both ends of the cable, it must be ensured that the double number on both ends of the cable is accurate. GD-2134A Cable Identifier is only suitable for on-site identification of de-energized cables. It is strictly forbidden to connect the cable identifier to the running power cable! Features ● Handheld receiver automatically identify and display the results to ensure that the results of cable identification are 100% accurate. Light weight and powerful, easy to carry. ● Suitable for on-site identification of de-energized cables. ● Both transmitter and handheld re...
  • OEM Best portable dew point meter Factory –  GDZL-503 Automatic Interfacial Tension tester – HV Hipot

    OEM Best portable dew point meter Factory – GDZL-503 Automatic Interfacial Tension tester – HV Hipot

    Intermolecular forces will generate interface tension and surface tension of liquids. The value of tension reflects liquid sample’s physics and chemical properties, which is one of the most important index for product quality. GDZL-503 automatic interfacial tension tester tests kinds of liquid surface tension and interface tension according to ring method which is simple and accurate. It is widely used in electric, petroleum, chemical,medicine, food and teaching filed. Features ● Exclusive and quick response electromagnetic balance sensor is adopted, to improve the accuracy of the measurement and degree of linearity. ● Only using one point calibration, to solve the problem of previous sensor which needs multi-point calibration. It is no need to use zero potentiometer and full s...
  • OEM Best Dc Circuit Breaker Price Suppliers –  GDSL-BX-100 Primary Current Injection Test Set – HV Hipot

    OEM Best Dc Circuit Breaker Price Suppliers – GDSL-BX-100 Primary Current Injection Test Set – HV Hipot

    Features Specifications ● Power supply: AC 220V 50Hz. ● Output power: 3kVA. ● Output current: 500A in series,1000A in parallel. ● Output voltage: 6V in series, 3V in parallel. ● Current can be adjusted smoothly and continuously. The accuracy is 1.0%. ● Output current is standard sine wave, waveform distortion is less than 5%. ● Output current: RMS continuous adjustable. ● Duty Cycle: 5mins ON, 10mins OFF. Accessories Main unit 1 piece Connection cable 1 piece 2m Output cable 2 pcs 1000A  Ground cable 1 piece Power cable 1 piece User’s guide 1 piece Factory test report 1 piece
  • China High Quality Partial Discharge Test Report Manufacturer –  GDJF-2007 Digital Partial Discharge Analyzer – HV Hipot

    China High Quality Partial Discharge Test Report Manufacturer – GDJF-2007 Digital Partial Discharge Analyzer – HV Hipot

    Picture only for reference first. GDJF-2007 Digital Partial Discharge Analyzer is widely used for detecting partial discharge of high voltage equipment such as power transformers, instrument transformer, HV circuit breaker, GIS, Zinc oxide surge arrester, power cable. It also can make type tests and monitor insulation operation. It includes main unit, PD software, current transformer, input unit, calibration pulse generator, input adapter, antenna amplifier and connection cable etc. Features ● 12inch LCD display, with portable design, rugged and durable, easy to use. ● Strong anti-interference ability, accurate. Using digital filtering technology, field interference can be effectively eliminated, and partial discharge measurement can be realized in a strong interference environmen...
  • China High Quality Order Capacitors Factory –  AC Dielectric Test Equipment with manual control unit GDYD-M – HV Hipot

    China High Quality Order Capacitors Factory – AC Dielectric Test Equipment with manual control unit GDYD-M – HV Hipot

    Application AC Hipot testing is the effective and direct way to test insulation strength for electric equipment, apparatus, or machines. It checks dangerous flaws which assure electric equipment continuous working. Typical applications include testing of transformers, switchgear, cables, capacitors, aerial motors platforms, hot sticks bucket bricks, vacuum bottles and other related equipment like vacuum interrupters, blankets, ropes, gloves, hydraulics hose, instruments transformers generators. Features ● Pointer display panel mounted controls & indicators with easy-to-read legend. ● Monitoring high voltage side voltage, low voltage side current and indicator of zero, power, working start, timing. ● Over-current protection, zero-starting protection, sound, and light alarm. ● C...
  • OEM Best point tester Manufacturer –  Transformer Oil Gas Chromatography Online Monitoring System – HV Hipot

    OEM Best point tester Manufacturer – Transformer Oil Gas Chromatography Online Monitoring System – HV Hipot

    General Information  GDDJ-DGA Transformer Oil Gas Analyzer is an online monitoring device for dissolved gas in transformer oil based on gas chromatography technology. Potential fault are determined, release alert as per preset value through expert diagnosis system. The device adopts distributed control sampling technology and has self-diagnosis and self-recovery functions. Each function module is weak coupling, function independent, adopting rack structure, easy for engineering maintenance. Features ● Maintenance-free, no need to replace gas cylinder. ● On-line detection the concentration and growth rate of H2, CO, CO2, CH4, C2H4, C2H2, C2H6. ● Modular design and compact structure, easy for maintenance, with high expansibility, can be easily integrated to other monitoring equipmen...
  • OEM Best Plastic Pipe Locator Manufacturer –  GD-7018A Optical Fiber Identifier – HV Hipot

    OEM Best Plastic Pipe Locator Manufacturer – GD-7018A Optical Fiber Identifier – HV Hipot

    The GD-7018 series optical fiber pipeline identifier can accurately locate and meaure depth of the underground pipelines, cables and optical cables under the condition of without digging, and accurately find the damage points of the outer coating of the underground pipelines and the location of the underground cable fault points. The instrument incorporates the most advanced technologies such as ultra-narrow band filter, Bluetooth wireless communication, GPS positioning, automatic data mapping by professional data analysis software and automatic generation of test reports. The detection and inspection of various kinds of metal pipelines, pipeline management and maintenance, municipal planning and construction, pipeline inspection in power supply and other departments is one of the neces...
  • China High Quality protection relay tester price Manufacturers –  GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot

    China High Quality protection relay tester price Manufacturers – GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot

    Features ● Output up to 6-phase voltage 6-phase current, which can be combined to realize conventional 4-phase voltage 3-phase current type, 6-phase voltage type, 6-phase current type, and 12-phase output mode. ● High-performance embedded industrial control computer and 8.4-inch large-screen high-resolution color TFT liquid crystal display, which can provide rich and intuitive information, including the current working status of the device, next working tips and various help information; ● The output uses a high-fidelity, high-reliability modular linear power amplifier instead of a switch-type power amplifier for superior performance. It will not generate high and medium frequency interference to the test site, and it will ensure excellent waveform smoothing and accuracy from high cu...
  • China High Quality types of partial discharge Manufacturer –  GD-610C Remote Ultrasonic Partial Discharge Detector – HV Hipot

    China High Quality types of partial discharge Manufacturer – GD-610C Remote Ultrasonic Partial Discharge Detector – HV Hipot

    Partial discharge is one of the common reasons of medium and high voltage equipment and cable insulation failures. Partial discharge testing can detect harmful defects and help identify potential future failures. The GD-610C remote ultrasonic partial discharge detector uses an ultrasonic spectrum probe (sensor) to collect ultrasonic signals and analyze the signal to diagnose the charged detection, it is a diagnosis device for the accident of the distribution line. The device determines the line position and the fault type of the faulty hidden line when it is live. After collecting the ultrasonic abnormal signal, it transmits signals to the host, converts it into an audible sound signal and waveform, and finally diagnoses the type of the hidden danger and grade by the analysis software. ...
  • China High Quality Vlf Hipot Test Supplier –  AC hipot test set for insulated boom GDYD-137 – HV Hipot

    China High Quality Vlf Hipot Test Supplier – AC hipot test set for insulated boom GDYD-137 – HV Hipot

    Application Technical Specifications Input AC 220V± 10%, 50Hz, 32.5A, Single phase Output 0-130kV, 50mA   0-36kV, 180mA Rating 25mA/90mA, continuous working 33.3kV/120mA, 1hour ON/1hour OFF 50mA/180mA, 5mins ON/15mins OFF Capacity 6.5kVA HT Source SF6 gas (Gas testing transformer) Output control Manual control Voltage accuracy ≤ 1.5% (F.S) Current Accuracy ≤ 1.5% (F.S) Timing range  0-99H Metering LCD display, kV meter: there is a switching button, the range is 0-36kVAC if it switches to 36kV, the range is 0-130kVAC if it switches to 130kV mA meter: 0-5.000mA  Humidity 85% RH Environmental temperature -20℃~50℃
  • China High Quality Check Capacitance With Multimeter Factory –  PD free Variable Frequency Test System – HV Hipot

    China High Quality Check Capacitance With Multimeter Factory – PD free Variable Frequency Test System – HV Hipot

    GDYT-350kVA/70kV PD free Resonant Test System is composed of PD free variable frequency power supply, HV measuring box, excitation transformer, isolation transformer, Resonant reactor, and capacitive voltage divider. This test system does not have the problem of excessive starting current. Using a smaller capacity power supply can complete a test equivalent to 30 to 60 times of the power supply, which greatly alleviates the problem of insufficient capacity of the field test power supply. Features ● Safety and reliable. It has many functions, including discharge and breakdown protection, over-voltage and over-current setting protection, test power off protection, zero protection, over-heat protection etc. When any protection happened, the system will immediately cut off output and po...
  • China High Quality closed cup flash point tester Manufacturers –  GDC-9560B Power System Insulation Oil Gas Chromatograph Analyzer – HV Hipot

    China High Quality closed cup flash point tester Manufacturers – GDC-9560B Power System Insulation Oil Gas Chromatograph Analyzer – HV Hipot

    General Information  GDC-9560B Gas Chromatograph Analyzer is to analyze the gas content of insulation oil by gas chromatographic method. It is effective to judge if the running equipment has potential fault like over-heat, discharge or not, to ensure the safety of power grid. It is also necessary to be used for manufacturer of gas/oil equipment to inspect their equipment before leaving factory. Gas chromatography analysis technology is a technique for separation and analysis of multi-component mixtures. It mainly uses the difference of boiling point, polarity and adsorption coefficient of each component in the sample in the column, so that the components are separated in the column, and the separated components are qualitatively and quantitatively analyzed. The gas chromatograph uses...