Featured

  • China High Quality lightning detection system Factory –  GDUD-PBI Ultrasonic Flaw Detector for Electrical Equipment – HV Hipot

    China High Quality lightning detection system Factory – GDUD-PBI Ultrasonic Flaw Detector for Electrical Equipment – HV Hipot

    Applications It detects internal flaws of electrical equipment, such as bushings, bus bars, wire clamps, transformer tank, current&voltage transformers, surge arresters, generator bearing equipment, and porcelain pillar type insulators, etc. Features ● TFT true color screen. ● High accuracy and wide applications. ● High sensitivity of flaw detection, up to 110db. ● Built-in standard curves and test block for pillar type insulators. The device alarms if internal crackle flaws are super-standard. ● Automatic calibrations for probe and curvature surface, which optimizes the coupling between the probe and test object and ensures accuracy. ● Aluminum alloy chassis, which has excellent anti-interference performance. Low noise and high signal-to-noise ratio. Specifications ● Worki...
  • China High Quality Pipe Locator Price Factories –  GD-4136H Cable Fault Locating System  – HV Hipot

    China High Quality Pipe Locator Price Factories – GD-4136H Cable Fault Locating System – HV Hipot

    GD4136H Cable Fault system is an important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1.GD-2131H Impulse Generator 2.GD-4132 Cable Fault Locator 3.GD-4133 Multi-pulse Cable Fault Detector 4.GD-4133S Multi-pulse Coupler 5.Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-4133 Cable Fault Tester, there are two locating ways: a. Low vol...
  • China High Quality Resistor Tester Supplier –  GDSL-BX-200 Primary Current Injection Test Set – HV Hipot

    China High Quality Resistor Tester Supplier – GDSL-BX-200 Primary Current Injection Test Set – HV Hipot

    Features ● Digital control, high anti reference ability. ● Adapts autotransformer regulator which with low power consumption and large capacitance. ● Converter has high permeability core. ● Quick connects, lock design, have good current capability. ● PVC panel. ● Build-in quick plug with high safety. ● Current range can be changed, easy to read. ● Engineering plastics box, IP67 dustproof and waterproof. ● Portable design is suitable for on-site testing. ● Zero start function to prevent the test objects from damage caused by high current impulsing. The equipment only can be started at zero. ● Impulse choosing function: The current value can be outputted directly without zero protection function when the equipment is under the testing for circuit breaker. ● 0-50A AC current can be outp...
  • OEM Best power distribution transformer Factory –  GDPD-414 Portable Partial Discharge Detector – HV Hipot

    OEM Best power distribution transformer Factory – GDPD-414 Portable Partial Discharge Detector – HV Hipot

    Main unit UHF sensor, round type, suitable for GIS UHF sensor, rectangle type, suitable for power cable, transformer, switchgear HFCT, suitable for power cable, transformer TEV sensor, suitable for switchgear Ultrasonic sensor, suitable for transformers, switchgear Above pictures are only for reference first. The GDPD-414 Portable (GDPD-414H handheld) Partial Discharge Detector adopts smart quick intelligent power test system (Soft No. 1010215, trademark registration number 14684781 (14684481)). It can flexibly configure various sensors according to different products to be tested. TEV, ultrasonic and HFCT are suitable for partial discharge detection of high-voltage switchgear and ring network cabinet; Ultrasonic and UHF are suitable for detecting G...
  • OEM Best Blocking Capacitor Factories –  30kVA.200kV Automatic AC.DC Hipot Test Set GDYD-2030A – HV Hipot

    OEM Best Blocking Capacitor Factories – 30kVA.200kV Automatic AC.DC Hipot Test Set GDYD-2030A – HV Hipot

    Features ● 7inch color LCD screen, with PLC automation control. ● HV Voltage, LV voltage, LC current measured at the same time, with high precision sensor and high-performance collection chip. ● Automatic mode and manual mode for option. ● Display HV voltage, LV voltage, LV current, time, and withstanding result. ● Over-voltage and over-current protection. Output voltage, HV current upper limit, LV current upper limit and timing can be set. ● Zero-starting function. Test can be proceeded after the voltage is back to zero. ● Store up to 8000pcs data in 3months. It has USB port to upload data to USB disk. ● When setting voltage is arrived, it will be timing automatically. After timing, voltage will be back to zero. ● When the LV current is over setting value, the voltage will be cut of...
  • China High Quality Sf6 Circuit Breaker Testing Factories –  GDKC-15 Series Circuit Breaker Analyzer 2020.12 – HV Hipot

    China High Quality Sf6 Circuit Breaker Testing Factories – GDKC-15 Series Circuit Breaker Analyzer 2020.12 – HV Hipot

    General Information High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-15 Series is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy.  GDKC-15 Series   GDKC-15A GDKC-15B GDKC-15C GDKC-15D GDKC-15E GDKC-15F GDKC-15G GDKC-15H Metal contact 12 12 12 12 12 12 12 12 Closing resistance   6 6 6 6 6 6 6 Graphite contact       3 3 3 3 6 Double-ended grounding         3 3 3 6 Dynamic resistance(Pre-insertion resistor) 1 1 3 3   3 3 6 Static resistance 1 1 3 3   3 3 6 Ground resistance             3 6 Features ● It is suitable for the mechanical test of all types of SF6 switches, GIS combination appliances, vacuum switches and oil switches. ● Strong an...
  • OEM Best Capacitor Spec Manufacturer –  VLF AC Hipot Test Set 80kV – HV Hipot

    OEM Best Capacitor Spec Manufacturer – VLF AC Hipot Test Set 80kV – HV Hipot

    Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. AC test can be further divided into power frequency, variable frequency and 0.1Hz very low frequency test, among which the last one is highly recommended by IEC, due to its remarkable advantages. Following is a comparison for DC, Power Frequency, Variable Frequency, and 0.1Hz test. Aspects DC Power Frequency Variable Frequency 0.1Hz Equivalency poor good good good Insulation Damage strong slight slight slight Operation Safety relatively low relatively low relatively low high Wiring Difficulty complicated complicated most complicated simple Volume smallest largest large smal...
  • China High Quality Insulator Faults Locator Suppliers –  GDYZ-301A Zinc Oxide Surge Arrester Tester – HV Hipot

    China High Quality Insulator Faults Locator Suppliers – GDYZ-301A Zinc Oxide Surge Arrester Tester – HV Hipot

    It is the special equipment of testing zinc oxide electric performance. The instrument can accurately and stably measure the arrester resistive current and the monitor counter action parameters while the equipment is running. It can also check the monitor ammeter.  Features ● 8inch color LCD touch screen, high speed thermal printer. ● The measurement data of wire and wireless is the same. ● Wireless sampling, with long distance. A. Wired: indoor use, or on-site where the PT sampling wiring cabinet is near with tested lightning arrester. B. Wireless: outdoor use, or on-site where the PT sampling wiring cabinet is far from tested lightning arrester, wireless distance is up to 1000M. ● Three-phase can be measured at the same time. The resistive current of 3channels can be measured at ...
  • OEM Best Live Cable Detector Factories –  GDCF-900T Vehicle Mounted Cable Fault Locating System – HV Hipot

    OEM Best Live Cable Detector Factories – GDCF-900T Vehicle Mounted Cable Fault Locating System – HV Hipot

    Vehicle Mounted Cable Fault Locator system is used for Cable Fault conditioning (burn-down), Pre-Location, Route Location, Pin-pointing & Testing of HV & LV cables of different types&sizes. The set is suitable to carrying out the above-mentioned multifunction on power cables of various voltage levels mainly 33KV, 11KV, 415V and control cables with 1.1 KV grade. The set shall be used for cable types namely XLPE, PVC, PILC with Al / Cu conductor. The cables are laid underground (under plain earth, trenches, or RCC surface, Horizontal Drilling in HDD Pipe), above ground or partly under & partly above ground with maximum cable length around 25Km. The cable fault locator is suitable for fault locating and pinpointing the following types of cable faults. ● High resistance ● L...
  • China High Quality Resistance Test Meter Manufacturers –  GMDL-02A HV Circuit Breaker Analog Device – HV Hipot

    China High Quality Resistance Test Meter Manufacturers – GMDL-02A HV Circuit Breaker Analog Device – HV Hipot

    General Information GMDL-02A high-voltage circuit breaker simulation device is manufactured using the principles of large-scale field programmable gate arrays, power electronic devices with protection, etc. The open coil is designed according to an independent loop, which can simulate the three-phase and split-phase operation of the voltage level of 6-110KV. The action behavior of the single open coil circuit breaker is suitable for the selection of power systems, industrial and mining enterprises, scientific research institutes, professional colleges, and protection manufacturers. It is used as a substitute for actual circuit breakers in the transmission test of the entire system of relay protection and automatic devices with switches. The action is accurate, reliable, and the numbe...
  • China High Quality Circuit Breaker Characteristics Tester Supplier –  GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot

    China High Quality Circuit Breaker Characteristics Tester Supplier – GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot

    Adoption of Standard ● DL/T 596-2005 “Procedure Test Procedures for Electrical Equipment” ● GB1094.1-GB1094.6-96 “Shell protection level” ● GB2900 “Electrical Terminology” ● GB/T16927.1~2-1997 “High Voltage Test Technology” ● GB4793-1984 “Safety Requirements for Electronic Measuring Instruments” ● GB191 “Package Storage and Transportation Mark” ● GB/T.311-1997 “Insulation and coordination of high voltage power transmission and transformation equipment” Features ● Using high conductivity copper as the output electrode, the contact surface is large and the flow capacity is strong. ● Brushed aluminum plate with a new process, simple and eye-catching, wear-resistant and pollution-resistant. ● The all-...
  • OEM Best analogue insulation tester 5kv Factory –  GD2000D Insulation Resistance Tester – HV Hipot

    OEM Best analogue insulation tester 5kv Factory – GD2000D Insulation Resistance Tester – HV Hipot

    General Information GD2000D digital insulation resistance tester produced by our company uses an embedded industrial single chip real-time operating system. The digital analog pointer and digital field code display are perfectly combined. This series of meters has a variety of voltage output levels (250V, 500V, 1000V, 2500V, 5000V, 10000V), large capacity, strong anti-interference, analog pointer and digital synchronous display, AC and DC dual-use, simple operation, automatic calculation of various insulation indicators (absorption ratio, polarization index), various measurement results with anti-power-down function, etc. It is an ideal test instrument for measuring the insulation resistance of large-capacity transformers, transformers, generators, high-voltage motors, power capacito...

Send your message to us:

Write your message here and send it to us