China High Quality earthing test Factories – GD3127 Series High Voltage Insulation Resistance Tester – HV Hipot
General Information GD3127 Series Insulation Resistance Tester is widely used in maintenance of electrical equipment in transformer substation, power plant, etc. It is suitable for carrying out measurement of insulation resistance(IR), polarization index(PI), absorption ratio (DAR), ramp(RAMP), filter(FR, 10s, 20s, 30s, 40s 4 choices), voltage(V), current(nA) of all kinds of high voltage equipment, including switchgear, transformers, reactors, capacitors, motors, generators and cables, etc. GD3127 Series is the perfect test tool for early identification and discovery of preventive or predictive maintenance plans for potential equipment failures. It is of great significance to ensure product quality and the safety of people and equipment in operation. The insulation performance of ele... -
China High Quality acidity test of transformer oil Manufacturers – GDBS-305 Automatic Flash Point Closed Cup Tester – HV Hipot
General Information GDBS-305 automatic closed cup flash point tester is the device testing closed cup flash point for petroleum products. It use module design which one host can control several testing furnace, to test different samples at the same time or separately. The testing furnace port can be connected to the host disorderly. It widely used in the field of railway, air company, power, petroleum and research department. Features ● 320*240 TFT LCD screen. ● With high speed signal processor control, reliable and high accuracy. ● One host can control several test furnace to test several samples at one time, which will save testing time. ● Automatic ignition with no gas source ignition mode. ● Built-in atmosphere pressure sensor, auto-measure and calibrate result. ● Self-adapti... -
China High Quality Testing Circuit Breakers Manufacturer – GDSL-BX-100 Primary Current Injection Test Set – HV Hipot
Features Specifications ● Power supply: AC 220V 50Hz. ● Output power: 3kVA. ● Output current: 500A in series,1000A in parallel. ● Output voltage: 6V in series, 3V in parallel. ● Current can be adjusted smoothly and continuously. The accuracy is 1.0%. ● Output current is standard sine wave, waveform distortion is less than 5%. ● Output current: RMS continuous adjustable. ● Duty Cycle: 5mins ON, 10mins OFF. Accessories Main unit 1 piece Connection cable 1 piece 2m Output cable 2 pcs 1000A Ground cable 1 piece Power cable 1 piece User’s guide 1 piece Factory test report 1 piece -
China High Quality Cable Fault Finder Supplier – GD-4136H Cable Fault Locating System – HV Hipot
GD4136H Cable Fault system is an important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1.GD-2131H Impulse Generator 2.GD-4132 Cable Fault Locator 3.GD-4133 Multi-pulse Cable Fault Detector 4.GD-4133S Multi-pulse Coupler 5.Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-4133 Cable Fault Tester, there are two locating ways: a. Low vol... -
OEM Best Circuit Breaker Characteristics Tester Manufacturer – GDHL-100B Contact Resistance Tester (Microhm Meter) – HV Hipot
Description The performance of the conductive circuit of the circuit breaker is important to ensure the safe operation of the switch. The pros and cons of the conductive performance can be reflected by the size of the resistance of the conductive loop. Therefore, the IEC standard and the manufacturer have stipulated that the loop resistance should be measured, and there are clear specifications for the loop resistance of various types of switches. The loop resistance tester is a testing instrument meets the requirements of GB50150-2006 and DL / T 845.4-2004 regulations. It is widely applicable to the measurement of contact resistance, loop resistance, cable, wire, and weld contact resistance of various electrical switches. Application ● High,middle and low voltage circuit breakers... -
China High Quality Sf6 Gas Dew Point Tester Suppliers – GDSF-411CPD SF6 Gas Comprehensive Analyzer – HV Hipot
General Information GDSF-411CPD SF6 gas comprehensive analyzer is a portable device designed to measure SF6 gas dew point, purity and decomposition product. The core component with chilled mirror method is used to test dew point, European sensor with infrared method to test SF6 gas purity and electrochemical sensor from Membrapor to test SF6 gas decomposition product. Besides, we also adopt professional hardware chips and excellent software algorithms of STMicroelectronics. Application Features Specification SF6 Humidity Measurement method Chilled mirror method (Stirling Refrigeration) Measurement range Dew point -100℃–+20℃(90s for single point measurement), error: better than ±0.2℃ Repeat-ability ± 0.1 ℃ Resolution 0.01℃ Display unit ℃, ppm, ℃ P20(convert... -
China High Quality Pulse Generator Impulus Signallar Manbaai Factories – GDOT-3B 100kV 3 Cups Insulation Oil Breakdown Voltage (BDV)Tester – HV Hipot
Standards IEC 156: 1995 Insulating liquids- Determination of the breakdown voltage at power frequency Features ● Adopts a microprocessor, three cups in one, and automatically completes the operations of boosting, holding, stirring, standing, calculating, printing, etc., and can perform oil circulation withstand voltage test in the range of 0-100kV. ● LCD screen display. ● The operation of this instrument is simple, the operator only needs to make simple settings, and the instrument will automatically complete the test of 1-3 oil samples according to the settings. For each oil sample, the breakdown voltage value and number of cycles are automatically stored. After the test is completed, the thermal printer can print out the breakdown voltage value and average value of each oil samp... -
OEM Best 3 phase power monitor Manufacturers – GDPQ-300A Handheld Power Quality Analyzer – HV Hipot
Features ● The instrument is a high-precision test instrument specially used to detect power quality problems such as waveform distortion, harmonic content and three-phase unbalance in the power grid. It also has the functions of electrical parameter test and vector analysis. ● Can accurately measure voltage, current, active power, reactive power, phase angle, power factor, frequency and other electrical parameters. ● It can display the vector diagram of the measured voltage and current. The user can analyze the vector diagram to get the correctness of the wiring of the metering equipment. ● The current is measured by a clamp-type transformer. Operator does not need to disconnect the current loop when measuring with a clamp-type current transformer, the measurement can be convenientl... -
OEM Best Online Partial Discharge Testing Manufacturer – GD-610C Remote Ultrasonic Partial Discharge Detector – HV Hipot
Partial discharge is one of the common reasons of medium and high voltage equipment and cable insulation failures. Partial discharge testing can detect harmful defects and help identify potential future failures. The GD-610C remote ultrasonic partial discharge detector uses an ultrasonic spectrum probe (sensor) to collect ultrasonic signals and analyze the signal to diagnose the charged detection, it is a diagnosis device for the accident of the distribution line. The device determines the line position and the fault type of the faulty hidden line when it is live. After collecting the ultrasonic abnormal signal, it transmits signals to the host, converts it into an audible sound signal and waveform, and finally diagnoses the type of the hidden danger and grade by the analysis software. ... -
OEM Best harga digital megger Supplier – GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot
General Information GD3126A (GD3126B) Insulation Resistance Tester is widely used in maintenance of electrical equipment in transformer substation, power plant, etc. It is suitable for carrying out measurement of insulation resistance (IR), absorption ratio (DAR), polarization index (PI), leakage current (Ix) and absorption capacitance (Cx) of all kinds of high voltage equipment, including switchgear, transformers, reactors, capacitors, motors, generators and cables, etc. Features ● Adopts microcomputer control, menu operation and large LCD screen dot matrix display with stable performance. ● Strong anti-interference ability, suitable for measuring in strong electromagnetic interference environment. ● Large capacity, can meet the requirements of high voltage, high resistance, lar... -
China High Quality Capacitor Checking Multimeter Factory – Partial Discharge Test System GDYT series – HV Hipot
GDYT is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities. It includes below components 1. Hipot Test Control Unit GDYD 2. PD-free Gas type transformer YDQW 3. Coupling capacitor 4. Protective resistor 5. Isolation filter LBQ 6. Partial discharge detector Features ● Advanced PD-free epoxy insulating tube, small partial discharge capacity. ● Low impedance voltage, better than national standard. ● Automatic co... -
OEM Best Ct Pt Metering Unit Manufacturer – GDHG-106B CT/PT Analyzer – HV Hipot
Features ● Finish all testing items by itself, no need to connect auxiliary equipment. ● Intelligent controller is adopted. ● Built-in printer, to print results easily. ● Large screen LCD, graphically display. ● Auto display excitation knee point value, 5% and 10% error curve. ● Save 3000 groups data and it is not lost after power down. ● With USB port. The data can be saved in USB disk and read by PC (WORD format file). ● Portable design, suitable for on-site test. ● Engineering plastic box with damping, strong and reliable. Specifications Main functions CT (protection type, metering type) PT Voltage current characteristic curve (excitation characteristic) Voltage current characteristic curve (excitation characteristic) Auto calculate knee point value Auto calculate knee p...