  • OEM Best Couple Capacitor Factory –  Variable Frequency AC Resonant Test System – HV Hipot

    OEM Best Couple Capacitor Factory – Variable Frequency AC Resonant Test System – HV Hipot

    Features ● Small size, light weight, portable design. ● Suitable for 35kV or below cables. ● Single parts not more than 30kg, easy to carry. ● 220V or 380V single phase power supply,convenient for on-site power sourcing. Specifications ● Rated output voltage: based on cable voltage, usually it is 2Uo or 3Uo. ● Output frequency: 20 -300Hz. ● Resonant voltage waveform: sine wave, THD ≤ 1%. ● Full load working time: continuous working time 60mins. ● Quality factor: max. load ≥ 20. ● Frequency adjustment: fineness 0.1Hz, instability ≤ 0.01%. ● Power supply: 220V or 380V single-phase.
  • OEM Best High Impedance Faults Manufacturer –  GD-4138H Cable Fault Locating System – HV Hipot

    OEM Best High Impedance Faults Manufacturer – GD-4138H Cable Fault Locating System – HV Hipot

    GD-4138H Mobile Cable Fault Locating System is important tool to maintain all kinds of cables. It is compatible equipment that can trace, locate the underground cables, with fault distance measurement and HV generation. As it is movable device, it is convenient to carry on-site. If acoustic locator is used together, it can locate accurate position of cable fault point. Application is underground cable, aerial cable, power cable, local cable, communication cable and fiber cable. Typical fault to be detected includes ● High impedance flash-over fault ● High impedance leak ● High/low resistive grounding ● Short-circuit fault ● Open-circuit fault ● Poor connection/Disconnection GD-4138L system includes ● GD-4138H main frame (Coupling device, Sphere gap, HV generator are inside) ● GD-...
  • OEM Best surge arrestor testing equipment Supplier –  GDYZ-301A Zinc Oxide Surge Arrester Tester – HV Hipot

    OEM Best surge arrestor testing equipment Supplier – GDYZ-301A Zinc Oxide Surge Arrester Tester – HV Hipot

    It is the special equipment of testing zinc oxide electric performance. The instrument can accurately and stably measure the arrester resistive current and the monitor counter action parameters while the equipment is running. It can also check the monitor ammeter.  Features ● 8inch color LCD touch screen, high speed thermal printer. ● The measurement data of wire and wireless is the same. ● Wireless sampling, with long distance. A. Wired: indoor use, or on-site where the PT sampling wiring cabinet is near with tested lightning arrester. B. Wireless: outdoor use, or on-site where the PT sampling wiring cabinet is far from tested lightning arrester, wireless distance is up to 1000M. ● Three-phase can be measured at the same time. The resistive current of 3channels can be measured at ...
  • OEM Best Square Pulse Wave Generator Factories –  GDCY-20B 20kV Impulse Voltage Tester (Basic Type) – HV Hipot

    OEM Best Square Pulse Wave Generator Factories – GDCY-20B 20kV Impulse Voltage Tester (Basic Type) – HV Hipot

    GDCY-12B Programmable Automatic Impulse Voltage Tester is mainly based on TB/T 2653, GB/T 17627, GB/T 16927, GB14048, GB7251, GB/T 16935, IEC 61730, GB4706, GB3048, JB/T 7083 and other standard requirements. It is mainly used for safety performance (dielectric performance) detection of low-voltage electrical appliances, high and low voltage switches, solar energy, electricity meters, relays, leakage protectors, etc. The impulse output can be controlled by computer, and the test report can be printed and generated.  (Picture only for reference first.) Features ● Manual/automatic/programmable mode: Manual mode adjusts impulse voltage manually by adjusting knob; Automatic mode adjusts impulse voltage automatically by the system; Programmable mode uses computer to control impulse vo...
  • OEM Best partial discharge testing of cables Manufacturer –  GDPD-414H Handheld Partial Discharge Detector – HV Hipot

    OEM Best partial discharge testing of cables Manufacturer – GDPD-414H Handheld Partial Discharge Detector – HV Hipot

    Pictures for reference only. The GDPD-414H handheld Partial Discharge Detector adopts smart quick intelligent power test system (Soft No. 1010215, trademark registration number 14684481). It can flexibly configure various sensors according to different products to be tested. TEV, ultrasonic and HFCT are suitable for partial discharge detection of high-voltage switchgear and ring network cabinet; Ultrasonic and UHF are suitable for detecting GIS; Ultrasonic and HFCT are suitable for testing power cable. The built-in expert diagnosis system can analyze the test data and judge the discharge energy and possible parts. It is widely used in electric power and railway. Features ● Portable ABS engineering chassis. All PD detection hosts, tablets, sensors, chargers and signal cables are placed...
  • OEM Best megger earth tester Manufacturer –  Online Insulation Monitoring Device for DC System – HV Hipot

    OEM Best megger earth tester Manufacturer – Online Insulation Monitoring Device for DC System – HV Hipot

    General Information GDF-5000/OL Online Insulation Monitoring Device for DC System is used for real-time online monitoring of insulation status of DC bus and branch. This device adopts the detection method of DC balanced resistance. It does not produce any AC or DC interference signal to busbar, and will not cause the artificial insulation resistance drop. It is suitable for power plants and substations of any voltage level. GDF-5000/OL’s unique stability and anti-distributed capacitance make it more suitable for bus system under complex working conditions, standard instrument structure, compact size, convenient installation and better applicability. GDF-5000/OL has LCD display, full software function control, perfect man-machine interface, easy operation and use. Features ● ...
  • China High Quality Generation Of Impulse Voltage Factories –  GDCL-10kA Impulse Current Generator – HV Hipot

    China High Quality Generation Of Impulse Voltage Factories – GDCL-10kA Impulse Current Generator – HV Hipot

    Working Environment ● Environmental temperature: -10℃ to 40℃ ● Related humidity: ≤ 85% RH ● Altitude: ≤ 1000m ● Indoor use ● No conductive dust, no fire or explosive danger, no corrosive metal or insulation gas. ● Power voltage waveform is sine wave, distortion rate <5% ● Earth resistance is no more than 1Ω. Applied Standard IEC60099-4: 2014 Surge Arresters-Part 4: Metal-oxide surge arresters without gaps for a.c. systems. GB311.1-1997 Insulation coordination of HV Power transmission and transformation. IEC 60060-1 High Voltage Testing Technique- General Testing Requirement. IEC 60060-2 High Voltage Testing Technique- Measurement System. GB/T16896.1-1997 Digital Recorder of High Voltage Impulse Test. DLT992-2006 Implementing Rules for Impulse Voltage Measurement. DL/T613-1997 T...
  • China High Quality fuel dew point Supplier –  Transformer Oil Gas Chromatography Online Monitoring System – HV Hipot

    China High Quality fuel dew point Supplier – Transformer Oil Gas Chromatography Online Monitoring System – HV Hipot

    General Information  GDDJ-DGA Transformer Oil Gas Analyzer is an online monitoring device for dissolved gas in transformer oil based on gas chromatography technology. Potential fault are determined, release alert as per preset value through expert diagnosis system. The device adopts distributed control sampling technology and has self-diagnosis and self-recovery functions. Each function module is weak coupling, function independent, adopting rack structure, easy for engineering maintenance. Features ● Maintenance-free, no need to replace gas cylinder. ● On-line detection the concentration and growth rate of H2, CO, CO2, CH4, C2H4, C2H2, C2H6. ● Modular design and compact structure, easy for maintenance, with high expansibility, can be easily integrated to other monitoring equipmen...
  • China High Quality Different Ct And Pt Suppliers –  GDHG-108A CT/PT Tester – HV Hipot

    China High Quality Different Ct And Pt Suppliers – GDHG-108A CT/PT Tester – HV Hipot

    GDHG-108A CT/PT Tester supports test voltage method to test bushings CTs which installed on transformer or inside switch-gear, suitable for the laboratory and on-site detection. Itcan be easily and conveniently done voltage current characteristic, transformer ratio, ratio and phase angle error, load test items on CT/PT. Features ● Using the voltage detection principle to measure CT and PT. ● To meet the requirements of GB1207, GB1208, GB168-47 (IEC60044-1.6) and other standards. ● No external auxiliary equipment, a single machine can complete all test items. ● With high speed micro printer: real-time print the test result. ● Using intelligent controller, operation is simple. ● 5inch LCD screen display. ● Automatically given CT/PT (excitation) knee point value. ● Auto display 5% and 1...
  • OEM Best Current Injector Price Factories –  GMDL-02A HV Circuit Breaker Analog Device – HV Hipot

    OEM Best Current Injector Price Factories – GMDL-02A HV Circuit Breaker Analog Device – HV Hipot

    General Information GMDL-02A high-voltage circuit breaker simulation device is manufactured using the principles of large-scale field programmable gate arrays, power electronic devices with protection, etc. The open coil is designed according to an independent loop, which can simulate the three-phase and split-phase operation of the voltage level of 6-110KV. The action behavior of the single open coil circuit breaker is suitable for the selection of power systems, industrial and mining enterprises, scientific research institutes, professional colleges, and protection manufacturers. It is used as a substitute for actual circuit breakers in the transmission test of the entire system of relay protection and automatic devices with switches. The action is accurate, reliable, and the numbe...
  • OEM Best Single Stage Impulse Generator Suppliers –  GDZRC series DC Winding Resistance Tester – HV Hipot

    OEM Best Single Stage Impulse Generator Suppliers – GDZRC series DC Winding Resistance Tester – HV Hipot

    Features ● Four leads measurement to ensure measuring accuracy. ● Program-controlled current source to increase measuring speed. ● Auto discharge and discharge indication function, to ensure safety and availability. ● LCD screen and Built-in Printer. Specifications Items Specifications Remark Testing current 1mA  10mA  1A  5A  10A   Measurement range 1mA: 10mA: 1A: 5A: 10A: 1Ω-20KΩ 1Ω-2KΩ 10mΩ-20Ω 1mΩ-4Ω 1mΩ-2Ω   GDZRC-20A DC Winding Resistance Tester Testing current 1A  5A  10A  20A Measurement range 1A: 10mΩ~20Ω 5A: 1mΩ~4Ω 10A: 1mΩ~2Ω 20A: 1mΩ~1Ω Weight About 10kg GDZRC series DC Winding Resistance Tester GDZRC-40A Testing current 2.5A  5A  10A  20A  40A Measurement range 2.5A:10mΩ-8Ω 5A: 1mΩ-4Ω 10A: 1mΩ-2Ω 20A: 1mΩ-1Ω 40A:1mΩ-500mΩ W...
  • OEM Best electrical earth testing Manufacturers –  GD2000H 10kV Insulation Resistance Tester – HV Hipot

    OEM Best electrical earth testing Manufacturers – GD2000H 10kV Insulation Resistance Tester – HV Hipot

    General Information This device can test insulation resistance (such as transformer, switchgear, leads, motor) of different modules in one system, to insulate and repair failure components. It is important to ensure products quality and security of person and equipment during operation by insulation test of checking test object to ground or adjacent conductors’ insulation. Before power on the system, use insulation test to verify if it is good to improve system performance. Insulation test is to find manufacturing process problems and equipment fault which can’t be found before failure happened. In EU, this test is compulsory, even to civil system. Features 1. Voltage output GD2000H (5kV/10kV).Resistance range 0-400GΩ. 2. Two modes display insulation resistance. 3. Aut...