OEM Best transformer insulation resistance test Exporters – GDPD-414H Handheld Partial Discharge Detector – HV Hipot
Pictures for reference only. The GDPD-414H handheld Partial Discharge Detector adopts smart quick intelligent power test system (Soft No. 1010215, trademark registration number 14684481). It can flexibly configure various sensors according to different products to be tested. TEV, ultrasonic and HFCT are suitable for partial discharge detection of high-voltage switchgear and ring network cabinet; Ultrasonic and UHF are suitable for detecting GIS; Ultrasonic and HFCT are suitable for testing power cable. The built-in expert diagnosis system can analyze the test data and judge the discharge energy and possible parts. It is widely used in electric power and railway. Features ● Portable ABS engineering chassis. All PD detection hosts, tablets, sensors, chargers and signal cables are placed... -
China High Quality Capacitor Spec Manufacturer – Insulation Materials Hipot Test Set GDJS-65 – HV Hipot
GDJS-65 Insulation Gloves Test Set It is used to test insulation performance for insulation gloves, boots, mats, hats, rod, Electroscope etc. It can test 6pcs insulation gloves/boots at the same time, also 5pcs insulation rods. Features Manual control unit ● Digital and real time display HV voltage, LV current, 6-way leak current and time. ● With leak current meter and over-current protection meter. ● With movable control unit, easy wiring and testing. ● Manual control, safety and reliability. ● With zero, power, operation, timing indicators. ● With over-current protection, zero-start protection, sound and light alarm, power protected switch. ● New type timer, broader timing range.(1s-99h). Other features ● HV source is oil immersed type testing transformer.(dry type and SF6 gas t... -
OEM Best Breaker Meter Factories – GDKC-15 Series Circuit Breaker Analyzer 2020.12 – HV Hipot
General Information High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-15 Series is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy. GDKC-15 Series GDKC-15A GDKC-15B GDKC-15C GDKC-15D GDKC-15E GDKC-15F GDKC-15G GDKC-15H Metal contact 12 12 12 12 12 12 12 12 Closing resistance 6 6 6 6 6 6 6 Graphite contact 3 3 3 3 6 Double-ended grounding 3 3 3 6 Dynamic resistance(Pre-insertion resistor) 1 1 3 3 3 3 6 Static resistance 1 1 3 3 3 3 6 Ground resistance 3 6 Features ● It is suitable for the mechanical test of all types of SF6 switches, GIS combination appliances, vacuum switches and oil switches. ● Strong an... -
China High Quality tension testing equipment Suppliers – GDND-800 Freezing Point Tester – HV Hipot
General Information 1. Transformer oil freezing point tester has the characteristics of exquisite structural design and unique manufacturing process. It conforms to GB/T 3535 and GB/T510 standards and is used to determine the pour point of petroleum products. 2. This instrument adopts compressor refrigeration technology to save energy, simple operation and long service life. Its main technical indicators such as cooling rate and cooling capacity have surpassed similar foreign products. Working conditions 1. The instrument should be placed on a flat and stable workbench, and air convection should be minimized in the environment. 2. This product may involve flammable materials when used. It is not allowed to have an open flame (or a device that produces spark) close to it during op... -
OEM Best Contact Resistance Tester Factory – GDZK-IV Vacuum Degree Tester for Vacuum Breaker – HV Hipot
Features ● Measure vacuum degree in vacuum interrupter for every types of breakers. ● Electromagnetic measuring method, Accurate and Reliable. ● No need to dismantle the vacuum breaker in measurement. ● 128*64 pixel LCD screen, easy to operate. The test results are directly compared with the standard values to determine whether they are qualified;Save, print and check testing data. ● RS-232 port, connecting with PC to download vacuum degree-ionic current curve, to estimate lifespan. ● Light weight, Portable. Specifications ● Power Supply: AC220V ± 20%, 50Hz. ● Testing Range: 10-5 ~10-1Pa. ● Electric field Voltage: 20kV. ● Magnetic field Voltage: 1600V. ● Accuracy: 20%-25% at 10-5 ~10-4. 15%-20% at 10-4 ~10-3 10%-15% at 10-3 ~10-2 5%-10% at 10-2 ~10-1 ● Ambient Temperature: -1... -
OEM Best Sf6 Gas Humidity Meter Exporters – GDSF-311WP SF6 Dew Point and Purity Tester – HV Hipot
General Information GDSF-311WP is ideal instrument when it is necessary to test water content and purity of SF6 gas. The core component is DRYCAP series sensors produced by Finland Vaisala company. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of gas moisture test instrument. Application ● Moisture monitoring of SF6 gas electrical equipment for electric power ● SF6 gas cylinder gas quality test ● High purity gas manufacturing ● Semiconductor industry dry gas supply ● Research and development use ● Clean room/dry house monitoring ● Metal heat treatment site and laboratory industrial gas humidity detection, such as air, CO2, N2, H2, O2, SF6, He, Ar and other inert gases. Features Specification SF6 ... -
OEM Best energized insulator tester Manufacturers – GDYZ-302 Wireless Zinc Oxide Surge Arrester Tester – HV Hipot
Product Description GDYZ-302 Zinc Oxide Arrester Live Tester is a special instrument used to test the electrical performance of Zinc Oxide Arrester. It is suitable for live or power-off detection of Zinc Oxide Arrester of various voltage levels, so that to found dangerous defects such as dampness of internal insulation and aging of valve plates in time. The instrument is simple to operate and easy to use. The entire measurement process is controlled by an industrial computer. It can measure the full current, resistive current and its harmonics, power frequency reference voltage and harmonics, active power and phase difference. Displays true waveforms of voltage and current. The instrument uses digital waveform analysis technology and software anti-interference methods such as harmoni... -
China High Quality Hv Tester Exporters – AC Inductance Resonance Test System for CVT – HV Hipot
GDTL AC Resonant Test System for CVT is series resonance with power frequency specially for CVT. It is smaller size and more lighter weight than traditional device, meet various CVT inspection requirements of voltage with 35kV, 66kV, 110kV, 220kV, 330kV, 500kV. According to customer’s requirement, the reactor can be divided into fixed and adjustable reactor. Features ● Small size, light weight, simple wiring. ● Dry or Oil type reactor, high mechanical strength, good insulation, high reliability. ● Large capacity margin, good output waveform, easy to operate. ● Fully protection function: zero protection, over-voltage protection, over-current protect functions. -
OEM Best isolation test Suppliers – GD2000D Insulation Resistance Tester – HV Hipot
General Information GD2000D digital insulation resistance tester produced by our company uses an embedded industrial single chip real-time operating system. The digital analog pointer and digital field code display are perfectly combined. This series of meters has a variety of voltage output levels (250V, 500V, 1000V, 2500V, 5000V, 10000V), large capacity, strong anti-interference, analog pointer and digital synchronous display, AC and DC dual-use, simple operation, automatic calculation of various insulation indicators (absorption ratio, polarization index), various measurement results with anti-power-down function, etc. It is an ideal test instrument for measuring the insulation resistance of large-capacity transformers, transformers, generators, high-voltage motors, power capacito... -
China High Quality Primary Injection Test Of Bus Bar Factories – GDZK-IV Vacuum Degree Tester for Vacuum Breaker – HV Hipot
Features ● Measure vacuum degree in vacuum interrupter for every types of breakers. ● Electromagnetic measuring method, Accurate and Reliable. ● No need to dismantle the vacuum breaker in measurement. ● 128*64 pixel LCD screen, easy to operate. The test results are directly compared with the standard values to determine whether they are qualified;Save, print and check testing data. ● RS-232 port, connecting with PC to download vacuum degree-ionic current curve, to estimate lifespan. ● Light weight, Portable. Specifications ● Power Supply: AC220V ± 20%, 50Hz. ● Testing Range: 10-5 ~10-1Pa. ● Electric field Voltage: 20kV. ● Magnetic field Voltage: 1600V. ● Accuracy: 20%-25% at 10-5 ~10-4. 15%-20% at 10-4 ~10-3 10%-15% at 10-3 ~10-2 5%-10% at 10-2 ~10-1 ● Ambient Temperature: -1... -
China High Quality 5kv megger Exporters – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot
General Information GDCR1000C, GDCR1000D non-contact phase tester is a major breakthrough in traditional phase sequence detection method. The traditional phase sequence detection is to strip the connection pole of three-phase wires, connect three bare clamps or test needles of phase sequence meter to three bare fire lines, while GDCR1000C and GDCR1000D adopt pincers non-contact induction measurement. The phase sequence can be detected by no need peeling off the wire and without touching the bare high-voltage fire wire, just directly clamping three super-inductive high-insulation clamps on the insulation skin of the three-phase fire wire respectively. At the same time, acousto-optic indication of the positive or reverse phase state of the phase sequence of the three-phase power supply... -
China High Quality Primary Current Injection Test Manufacturers – GDKC-15 Series Circuit Breaker Analyzer 2020.12 – HV Hipot
General Information High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-15 Series is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy. GDKC-15 Series GDKC-15A GDKC-15B GDKC-15C GDKC-15D GDKC-15E GDKC-15F GDKC-15G GDKC-15H Metal contact 12 12 12 12 12 12 12 12 Closing resistance 6 6 6 6 6 6 6 Graphite contact 3 3 3 3 6 Double-ended grounding 3 3 3 6 Dynamic resistance(Pre-insertion resistor) 1 1 3 3 3 3 6 Static resistance 1 1 3 3 3 3 6 Ground resistance 3 6 Features ● It is suitable for the mechanical test of all types of SF6 switches, GIS combination appliances, vacuum switches and oil switches. ● Strong an...