-
OEM Best Plastic Pipe Locator Exporters – GD-2134E Cable Identifier – HV Hipot
GD-2134E is a high-performance underground metal pipeline detection system composed of signal transmitters and receivers. It can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables. It can carry out uniqueness identification with a variety of selected accessories, as well as pipe insulation damage and the search for some types of cable faults. Features ● Compass display: intuitively displays the pipeline location and left & right directions. ● Tracking true and false prompts: current direction measurement, tracking correct error prompts, eliminating line interference (some frequencies). ● Depth and current measurements, can display the signal strength historical curve. ● Fully digital high-precision sampling processing: sta... -
OEM Best Loop Resistance Tester Manufacturer – GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot
Adoption of Standard ● DL/T 596-2005 “Procedure Test Procedures for Electrical Equipment” ● GB1094.1-GB1094.6-96 “Shell protection level” ● GB2900 “Electrical Terminology” ● GB/T16927.1~2-1997 “High Voltage Test Technology” ● GB4793-1984 “Safety Requirements for Electronic Measuring Instruments” ● GB191 “Package Storage and Transportation Mark” ● GB/T.311-1997 “Insulation and coordination of high voltage power transmission and transformation equipment” Features ● Using high conductivity copper as the output electrode, the contact surface is large and the flow capacity is strong. ● Brushed aluminum plate with a new process, simple and eye-catching, wear-resistant and pollution-resistant. ● The all-... -
OEM Best Breaker Timing Test Supplier – GMDL-02A HV Circuit Breaker Analog Device – HV Hipot
General Information GMDL-02A high-voltage circuit breaker simulation device is manufactured using the principles of large-scale field programmable gate arrays, power electronic devices with protection, etc. The open coil is designed according to an independent loop, which can simulate the three-phase and split-phase operation of the voltage level of 6-110KV. The action behavior of the single open coil circuit breaker is suitable for the selection of power systems, industrial and mining enterprises, scientific research institutes, professional colleges, and protection manufacturers. It is used as a substitute for actual circuit breakers in the transmission test of the entire system of relay protection and automatic devices with switches. The action is accurate, reliable, and the numbe... -
China High Quality Hv Tester Suppliers – VLF AC Hipot Test Set – HV Hipot
Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. AC test can be further divided into power frequency, variable frequency and 0.1Hz very low frequency test, among which the last one is highly recommended by IEC, due to its remarkable advantages. Following is a comparison for DC, Power Frequency, Variable Frequency, and 0.1Hz test. Aspects DC Power Frequency Variable Frequency 0.1Hz Equivalency poor good good good Insulation Damage strong slight slight slight Operation Safety relatively low relatively low relatively low high Wiring Difficulty complicated complicated most complicated simple Volume smallest largest large smal... -
China High Quality grounding resistance Factories – GDCR3000B Digital Earth Resistance Tester – HV Hipot
General Information GDCR3000B Earth Resistance/Soil Resistivity Tester is special designed for measuring earth resistance, soil resistivity, earth voltage and AC voltage. The latest digital and micro processing technology is adopted, to measure earth resistance by 4-pole, 3-pole or 2-pole. FFT(Fourier transform) technology, AFC(automatic frequency control) technology is also available, with good anti-interference ability and the ability to adapt to the environment, to ensure high precision, high stability and reliability. It’s widely used for measurement of electric power, telecommunications, meteorology, oil field, construction, lightening protection, industrial electrical equipment. GDCR3000B is composed of host machine, monitoring software, testing cables, auxiliary earthing rod, ... -
China High Quality power monitoring Supplier – GDYM-3M Multi-functional Electric Energy Meter Calibrator – HV Hipot
Features Latest features 1. 32-bit high speed digital signal processor Using 32-bit high speed 120MHz DPS of TI, and high performance 16-bit AD with 6 channels. The digital multiplier units with multiple functions and wide range of measurement was successfully developed by means of floating point computations.Therefore, the calculating accuracy can be guaranteed. 2. Wring simulation function The various wiring methods can be simulated and obtain their corresponding results in office by the calibrator without connecting voltage or current signals.This function will be used as training materials and tools for training line inspection skills. Enable to greatly improve the inspection skills for on-site working staffs. 3. Error self-checking for 5A clamp The 5A and 0.5A current signal wil... -
China High Quality protection relay test equipment Manufacturers – GDJB-6000D Smart Substation Relay Protection Test System – HV Hipot
GDJB-6000D is equipped with high-performance power amplifier and based on the powerful PowerPC+X86 platform. It adopts modular design and have powerful functions, high precision, small size and light weight features. It can test the function and performance of merging unit, relay protection device, measurement and control device, intelligent terminals etc. Very suitable for power plants, substations, various scientific research units and equipment manufacturing enterprises. Features ● Smart Test Module Intelligent test template editing is supported. Test items can be randomly added during the test process and saved as reusable test project files to improve the test efficiency in the final stage of inspection and elimination. ● Automatic testing With on-site protection and digital pr... -
OEM Best grounding tester Factory – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot
General Information GDCR1000C, GDCR1000D non-contact phase tester is a major breakthrough in traditional phase sequence detection method. The traditional phase sequence detection is to strip the connection pole of three-phase wires, connect three bare clamps or test needles of phase sequence meter to three bare fire lines, while GDCR1000C and GDCR1000D adopt pincers non-contact induction measurement. The phase sequence can be detected by no need peeling off the wire and without touching the bare high-voltage fire wire, just directly clamping three super-inductive high-insulation clamps on the insulation skin of the three-phase fire wire respectively. At the same time, acousto-optic indication of the positive or reverse phase state of the phase sequence of the three-phase power supply... -
OEM Best ndt equipment Factories – GDYZ-301 Zinc Oxide Surge Arrester Tester – HV Hipot
Features 1. 800*480 color LCD touch screen, with high speed thermal printer. 2. Graphic display, intuitive interface, easy to operate and use on-site. 3. Long distance wireless transmission. PT signal wireless transmission distance more than 400m (2000m can be customized). 4. Suitable for testing in various situation such as lightning arrester with or without electricity, laboratory. 5. Test three phase current, three phase voltage at the same time, more efficient. 6. No strong electricity inside, voltage not more than 12V. Current and voltage sensors are completely isolated, safe and reliable. 7. Support various voltage sampling: 1. Wired; 2 wireless; 3. Non-voltage; A. Wire: digital signal transmission with cable which the signal is from PT metering winding; B. Wireless: digital s... -
China High Quality motor winding resistance test Supplier – Dielectric Loss Tester for Live Capacitive Equipment GDDJ-HVC – HV Hipot
General Information There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. If the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be found in ... -
OEM Best Capacitance Setting Multimeter Exporters – DC Hipot Test Set GDZG-S – HV Hipot
Features ● Electronic control and tune, easy to operate. ● The date of voltage and current are recorded in the panel, reading without conversion. ● One minute timing and tip function. ● Perfect overvoltage and over-current protection function inside, also zinc oxide overvoltage protection outside, which ensure safety of generator. ● Both control unit and doubler packed with special shockproof aluminum alloy cabinet, easy to move. ● Portable design, suitable for on-site testing. Specifications Items(kV/mA) parameter 50/100 50/120 60/150 60/200 60/300 Output voltage(kV) 50 50 60 60 60 Output current(mA) 100 120 150 200 300 Output power(W) 5000 6000 9000 12000 18000 Voltage measurement error ≤1.0% ±1digit Current measu... -
China High Quality grid substation earthing Suppliers – GDDT-10U Digital Grounding Down Lead Earth Continuity Tester – HV Hipot
General Information GDDT-10U Earth Continuity Resistance Tester is a highly automatic and portable test equipment. It is applied to the measurement of breakover resistance value among earth connecting cables of substation electrical equipment. The adoption of high-performance single-chip control helps to achieve intelligence of testing process. It is small size, convenient to carry, easy to operate, high-accuracy, fast testing speed, good testing repeatability, clear to read. Features ● The instrument is controlled by high-speed single chip, thus it’s highly automatic and easy to operate. ● Using new power source technology, with many more current steps and wide measuring range. ● Intelligent power management technology, the instrument can work in the state of Min. power, w...