OEM Best Ac Withstand Test Factory – PD free Variable Frequency Test System – HV Hipot
GDYT-350kVA/70kV PD free Resonant Test System is composed of PD free variable frequency power supply, HV measuring box, excitation transformer, isolation transformer, Resonant reactor, and capacitive voltage divider. This test system does not have the problem of excessive starting current. Using a smaller capacity power supply can complete a test equivalent to 30 to 60 times of the power supply, which greatly alleviates the problem of insufficient capacity of the field test power supply. Features ● Safety and reliable. It has many functions, including discharge and breakdown protection, over-voltage and over-current setting protection, test power off protection, zero protection, over-heat protection etc. When any protection happened, the system will immediately cut off output and po... -
China High Quality decade boxes Manufacturer – GDHX-9700 Phase Detector – HV Hipot
General Information GDHX-9700 Phase Detector is mainly used in electric power lines, phase, and phase sequence calibration in substation, with main functions including electrical inspection, phase calibration and phase sequence measurement. It uses double shielding and brand-new digital circuits, with strong anti-interference, accorded with EMC standards, suitable for various electromagnetic interference situations. The high voltage phase signal of measured lead will be transmitted directly after treatment, the handset will receive and make phase comparison, determine the results after phase detection, real-time display phase angle difference and vector. It uses wireless transmission technology, safe and reliable, fast, and accurate, suitable for using at different voltage levels (10... -
China High Quality Vacuum Breaker Tester Suppliers – GDHL-100A Micro-Ohmmeter – HV Hipot
General Information GDHL-100A Micro-Ohmmeter is widely used to measure loop resistance and contact resistance for weld joints, cables, and various HV switches within power industry. It uses intelligent power test system “Smart-Quick”, which is granted software copyright, and advanced detection technology. Features ● Adopt high-precision constant current power supply, automatic rising current mode without manual adjustment, the test is fast and accurate. ● Use four-terminal wiring method, effectively eliminate the interference produced by test cable resistance; ● Wide range, high accuracy, the resistance measurement range is up to 99mΩ. ● Multiple test times can be set, which meets various on-site applications; ● Large current output for a long time, burning the switch ... -
OEM Best Primary Injection Testing Solutions Exporters – GDHL-200A (GDHL-100A) Micro-Ohmmeter new – HV Hipot
General Information GDHL-200A (GDHL-100A) Micro-Ohmmeter is widely used to measure loop resistance and contact resistance for weld joints, cables, and various HV switches within power industry. It uses intelligent power test system “Smart-Quick”, which is granted software copyright, and advanced detection technology. Features ● Adopt high-precision constant current power supply, automatic rising current mode without manual adjustment, the test is fast and accurate. ● Use four-terminal wiring method, effectively eliminate the interference produced by test cable resistance. ● Wide range, high accuracy, the resistance measurement range is up to 99mΩ. ● At 200A, max. test time can reach 1~999s, which meets various on-site applications. ● Large current output for a long tim... -
OEM Best ultrasonic testing instrument Supplier – GDYZ-301A Zinc Oxide Surge Arrester Tester – HV Hipot
It is the special equipment of testing zinc oxide electric performance. The instrument can accurately and stably measure the arrester resistive current and the monitor counter action parameters while the equipment is running. It can also check the monitor ammeter. Features ● 8inch color LCD touch screen, high speed thermal printer. ● The measurement data of wire and wireless is the same. ● Wireless sampling, with long distance. A. Wired: indoor use, or on-site where the PT sampling wiring cabinet is near with tested lightning arrester. B. Wireless: outdoor use, or on-site where the PT sampling wiring cabinet is far from tested lightning arrester, wireless distance is up to 1000M. ● Three-phase can be measured at the same time. The resistive current of 3channels can be measured at ... -
OEM Best Capacitor Suppliers – PD free Variable Frequency Test System – HV Hipot
GDYT-350kVA/70kV PD free Resonant Test System is composed of PD free variable frequency power supply, HV measuring box, excitation transformer, isolation transformer, Resonant reactor, and capacitive voltage divider. This test system does not have the problem of excessive starting current. Using a smaller capacity power supply can complete a test equivalent to 30 to 60 times of the power supply, which greatly alleviates the problem of insufficient capacity of the field test power supply. Features ● Safety and reliable. It has many functions, including discharge and breakdown protection, over-voltage and over-current setting protection, test power off protection, zero protection, over-heat protection etc. When any protection happened, the system will immediately cut off output and po... -
China High Quality measure ground resistance Factories – Online Monitoring System of Circulating Current on Cable Sheath GDCO-301 – HV Hipot
General Information Cables above 35kV are mainly single-core cables with metal sheath. Since the metal sheath of the single-core cable is hinged with the magnetic field line generated by the AC current in the core wire, the two ends of the single-core cable have a high induced voltage. Therefore, appropriate grounding measures should be taken to keep the induced voltage within the safe voltage range (usually no more than 50V, but no more than 100V with safety measures). Usually, the metal sheath of short line single-core cable is grounded directly at one end and grounded through gap or protection resistor at the other end. The metal sheath of long line single – core cable is grounded by three – phase segmental cross – connection. No matter which kind of grounding me... -
OEM Best electrical partial discharge Manufacturer – GDPD-313M Portable Partial Discharge Detector – HV Hipot
External flexible sensor (for option) Parabolic sensor (wave condenser, for option) TEV and AE method is acknowledged and suitable technology to be used in online partial discharge detection. GDPD-313M uses ultrasonic detection technology (AE) and TEV mode, which can effectively ensure signal sensitivity in the interference on-site environment. It is suitable to detect PD flaw and locate PD signal for switch cabinet etc. Features ● Built-in ultrasonic sensor. electrical fault generates ultrasonic wave at the fault point, and ultrasonic mode transmits the ultrasonic signal through the earphone to scan the area to detect the discharge. Various characteristics of vibration, pop, and hum can be associated with different faults. ● Built-in high-precision TEV sensor, coupled with electrom... -
OEM Best megger products Factories – Online Monitoring System of Circulating Current on Cable Sheath GDCO-301 – HV Hipot
General Information Cables above 35kV are mainly single-core cables with metal sheath. Since the metal sheath of the single-core cable is hinged with the magnetic field line generated by the AC current in the core wire, the two ends of the single-core cable have a high induced voltage. Therefore, appropriate grounding measures should be taken to keep the induced voltage within the safe voltage range (usually no more than 50V, but no more than 100V with safety measures). Usually, the metal sheath of short line single-core cable is grounded directly at one end and grounded through gap or protection resistor at the other end. The metal sheath of long line single – core cable is grounded by three – phase segmental cross – connection. No matter which kind of grounding me... -
OEM Best Test Insulation Resistance Manufacturers – GDHL-100B Contact Resistance Tester (Microhm Meter) – HV Hipot
Description The performance of the conductive circuit of the circuit breaker is important to ensure the safe operation of the switch. The pros and cons of the conductive performance can be reflected by the size of the resistance of the conductive loop. Therefore, the IEC standard and the manufacturer have stipulated that the loop resistance should be measured, and there are clear specifications for the loop resistance of various types of switches. The loop resistance tester is a testing instrument meets the requirements of GB50150-2006 and DL / T 845.4-2004 regulations. It is widely applicable to the measurement of contact resistance, loop resistance, cable, wire, and weld contact resistance of various electrical switches. Application ● High,middle and low voltage circuit breakers... -
China High Quality Gas Recovery Unit Manufacturer – GDWG-III SF6 Gas Leakage Detector – HV Hipot
Product Description GDWG-III SF6 gas leakage detector, with non-dispersed infrared (NDIR) technology, is mainly used to pinpoint and measure SF6 leakage on GIS and refilling equipment within power industry. The annual leakage rate of SF6 gas electrical equipment is measured with bandaging method. At the same time, the equipment is widely used in power supply bureau, substations, high voltage switch company, laboratory hood and scientific test. Application ● High voltage switchgear ● Helicopter rotor blades ● Gas transmission system ● Fire extinguisher ● Ventilation rate study ● Hazardous material ● Tank Advantages ● No radioactive risk. ● No need to replace high purity argon gas regularly. ● No need to replace sensor regularly, cost-effective. ● No need to make linear calibrati... -
OEM Best use of earth tester Factories – GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot
General Information GD3126A (GD3126B) Insulation Resistance Tester is widely used in maintenance of electrical equipment in transformer substation, power plant, etc. It is suitable for carrying out measurement of insulation resistance (IR), absorption ratio (DAR), polarization index (PI), leakage current (Ix) and absorption capacitance (Cx) of all kinds of high voltage equipment, including switchgear, transformers, reactors, capacitors, motors, generators and cables, etc. Features ● Adopts microcomputer control, menu operation and large LCD screen dot matrix display with stable performance. ● Strong anti-interference ability, suitable for measuring in strong electromagnetic interference environment. ● Large capacity, can meet the requirements of high voltage, high resistance, lar...