-
OEM Best Microohm Meter Manufacturers – GDZK-IV Vacuum Degree Tester for Vacuum Breaker – HV Hipot
Features ● Measure vacuum degree in vacuum interrupter for every types of breakers. ● Electromagnetic measuring method, Accurate and Reliable. ● No need to dismantle the vacuum breaker in measurement. ● 128*64 pixel LCD screen, easy to operate. The test results are directly compared with the standard values to determine whether they are qualified;Save, print and check testing data. ● RS-232 port, connecting with PC to download vacuum degree-ionic current curve, to estimate lifespan. ● Light weight, Portable. Specifications ● Power Supply: AC220V ± 20%, 50Hz. ● Testing Range: 10-5 ~10-1Pa. ● Electric field Voltage: 20kV. ● Magnetic field Voltage: 1600V. ● Accuracy: 20%-25% at 10-5 ~10-4. 15%-20% at 10-4 ~10-3 10%-15% at 10-3 ~10-2 5%-10% at 10-2 ~10-1 ● Ambient Temperature: -1... -
OEM Best Simulate Lightning Impulse Exporters – Impulse Voltage Test System – HV Hipot
Features ● Complete equipment and wide voltage levels in the whole set of device. ● Small electric inductance in the return circuit of the impulse voltage generator, A band-stop filtering is adopted so that a standard impulse wave is still generated even under a large capacity load, and large load capacity. ● Large in voltage utilization coefficient. ● Convenient in wave adjustment, simple in operation, excellent in synchronization performance and reliable in motion. ● An automatic control technique is adopted in the constant-current charge, which is high automation and strong anti-interference capacity. ● A digital measurement and analysis system for the impulse test date are adopted, which increase the technical level and the efficiency of the impulse voltage tests. Specifications ... -
OEM Best Voltage Coupling Supplier – AC Dielectric Test Equipment with manual control unit GDYD-D – HV Hipot
Application Features ● Digital (Pointe) display panel mounted controls & indicators with easy-to-read legend. ● Monitoring high voltage side voltage, low voltage side current and indicator of zero, power, working start, timing. ● Over-current protection, zero-starting protection, sound, and light alarm. ● Continuously variable output from zero to full voltage. ● Adjustable over current protection, with trip levels variable from 10 to 110%. ● With new type time relay, time range is wider (1S ~ 99H). ● Using the latest current relay, more accurate and reliable. ● Light weight, small size, easy to move. Technical Specifications ● Input voltage: AC 220V or 380V ● Output voltage of control unit: AC 0-250V or 0-430V ● Output current of control unit:0-5/10/15/50A(customized) ● Ca... -
China High Quality Hv Capacitor Price Manufacturer – 30kVA.200kV Automatic AC.DC Hipot Test Set GDYD-2030A – HV Hipot
Features ● 7inch color LCD screen, with PLC automation control. ● HV Voltage, LV voltage, LC current measured at the same time, with high precision sensor and high-performance collection chip. ● Automatic mode and manual mode for option. ● Display HV voltage, LV voltage, LV current, time, and withstanding result. ● Over-voltage and over-current protection. Output voltage, HV current upper limit, LV current upper limit and timing can be set. ● Zero-starting function. Test can be proceeded after the voltage is back to zero. ● Store up to 8000pcs data in 3months. It has USB port to upload data to USB disk. ● When setting voltage is arrived, it will be timing automatically. After timing, voltage will be back to zero. ● When the LV current is over setting value, the voltage will be cut of... -
China High Quality Online PD Testing Factory – GDPD-3000C Portable Partial Discharge Detector – HV Hipot
GDPD-3000C Portable Ultrasonic Partial Discharge Detector uses advanced cloud computing and automatic modeling technology to achieve the partial discharge signal measurement, recording, transmission, storage, analysis and exchange, providing powerful technical support for on-site measurement of partial discharge. The measurement personnel collect the partial discharge information by using GDPD-3000C, and the cloud computing can be used to intelligently diagnose the insulation state of detection equipment in real time. Specification Hardware ● Processor: high performance intelligent processor. ● Screen: 4.3inch Touch Screen. ● Operation keys: PVE film keyboard. ● Interface: ● 3.5mm stereo headphone interface ● DC LV current charging interface ● USB 2.0 3G wireless network in... -
China High Quality Primary Current Injection Test Price Exporters – GDHL-100A Micro-Ohmmeter – HV Hipot
General Information GDHL-100A Micro-Ohmmeter is widely used to measure loop resistance and contact resistance for weld joints, cables, and various HV switches within power industry. It uses intelligent power test system “Smart-Quick”, which is granted software copyright, and advanced detection technology. Features ● Adopt high-precision constant current power supply, automatic rising current mode without manual adjustment, the test is fast and accurate. ● Use four-terminal wiring method, effectively eliminate the interference produced by test cable resistance; ● Wide range, high accuracy, the resistance measurement range is up to 99mΩ. ● Multiple test times can be set, which meets various on-site applications; ● Large current output for a long time, burning the switch ... -
China High Quality Water Line Locator Suppliers – GD-7018A Optical Fiber Identifier – HV Hipot
The GD-7018 series optical fiber pipeline identifier can accurately locate and meaure depth of the underground pipelines, cables and optical cables under the condition of without digging, and accurately find the damage points of the outer coating of the underground pipelines and the location of the underground cable fault points. The instrument incorporates the most advanced technologies such as ultra-narrow band filter, Bluetooth wireless communication, GPS positioning, automatic data mapping by professional data analysis software and automatic generation of test reports. The detection and inspection of various kinds of metal pipelines, pipeline management and maintenance, municipal planning and construction, pipeline inspection in power supply and other departments is one of the neces... -
China High Quality High Voltage Instruments Exporters – GDCY-20B 20kV Impulse Voltage Tester (Basic Type) – HV Hipot
GDCY-12B Programmable Automatic Impulse Voltage Tester is mainly based on TB/T 2653, GB/T 17627, GB/T 16927, GB14048, GB7251, GB/T 16935, IEC 61730, GB4706, GB3048, JB/T 7083 and other standard requirements. It is mainly used for safety performance (dielectric performance) detection of low-voltage electrical appliances, high and low voltage switches, solar energy, electricity meters, relays, leakage protectors, etc. The impulse output can be controlled by computer, and the test report can be printed and generated. (Picture only for reference first.) Features ● Manual/automatic/programmable mode: Manual mode adjusts impulse voltage manually by adjusting knob; Automatic mode adjusts impulse voltage automatically by the system; Programmable mode uses computer to control impulse vo... -
OEM Best dew point to relative humidity Exporters – GDZL-503 Automatic Interfacial Tension tester – HV Hipot
Intermolecular forces will generate interface tension and surface tension of liquids. The value of tension reflects liquid sample’s physics and chemical properties, which is one of the most important index for product quality. GDZL-503 automatic interfacial tension tester tests kinds of liquid surface tension and interface tension according to ring method which is simple and accurate. It is widely used in electric, petroleum, chemical,medicine, food and teaching filed. Features ● Exclusive and quick response electromagnetic balance sensor is adopted, to improve the accuracy of the measurement and degree of linearity. ● Only using one point calibration, to solve the problem of previous sensor which needs multi-point calibration. It is no need to use zero potentiometer and full s... -
OEM Best Multimeter Capacitance Manufacturers – DC Hipot Test Set GDZG-S – HV Hipot
Features ● Electronic control and tune, easy to operate. ● The date of voltage and current are recorded in the panel, reading without conversion. ● One minute timing and tip function. ● Perfect overvoltage and over-current protection function inside, also zinc oxide overvoltage protection outside, which ensure safety of generator. ● Both control unit and doubler packed with special shockproof aluminum alloy cabinet, easy to move. ● Portable design, suitable for on-site testing. Specifications Items(kV/mA) parameter 50/100 50/120 60/150 60/200 60/300 Output voltage(kV) 50 50 60 60 60 Output current(mA) 100 120 150 200 300 Output power(W) 5000 6000 9000 12000 18000 Voltage measurement error ≤1.0% ±1digit Current measu... -
China High Quality insulation resistance testing of cables Exporters – GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot
General Information GD3126A (GD3126B) Insulation Resistance Tester is widely used in maintenance of electrical equipment in transformer substation, power plant, etc. It is suitable for carrying out measurement of insulation resistance (IR), absorption ratio (DAR), polarization index (PI), leakage current (Ix) and absorption capacitance (Cx) of all kinds of high voltage equipment, including switchgear, transformers, reactors, capacitors, motors, generators and cables, etc. Features ● Adopts microcomputer control, menu operation and large LCD screen dot matrix display with stable performance. ● Strong anti-interference ability, suitable for measuring in strong electromagnetic interference environment. ● Large capacity, can meet the requirements of high voltage, high resistance, lar... -
China High Quality Contact Resistance Measurement Suppliers – GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot
Adoption of Standard ● DL/T 596-2005 “Procedure Test Procedures for Electrical Equipment” ● GB1094.1-GB1094.6-96 “Shell protection level” ● GB2900 “Electrical Terminology” ● GB/T16927.1~2-1997 “High Voltage Test Technology” ● GB4793-1984 “Safety Requirements for Electronic Measuring Instruments” ● GB191 “Package Storage and Transportation Mark” ● GB/T.311-1997 “Insulation and coordination of high voltage power transmission and transformation equipment” Features ● Using high conductivity copper as the output electrode, the contact surface is large and the flow capacity is strong. ● Brushed aluminum plate with a new process, simple and eye-catching, wear-resistant and pollution-resistant. ● The all-...