China High Quality Capacitor Testing Machine Exporters – 30kVA.200kV Automatic AC.DC Hipot Test Set GDYD-2030A – HV Hipot
Features ● 7inch color LCD screen, with PLC automation control. ● HV Voltage, LV voltage, LC current measured at the same time, with high precision sensor and high-performance collection chip. ● Automatic mode and manual mode for option. ● Display HV voltage, LV voltage, LV current, time, and withstanding result. ● Over-voltage and over-current protection. Output voltage, HV current upper limit, LV current upper limit and timing can be set. ● Zero-starting function. Test can be proceeded after the voltage is back to zero. ● Store up to 8000pcs data in 3months. It has USB port to upload data to USB disk. ● When setting voltage is arrived, it will be timing automatically. After timing, voltage will be back to zero. ● When the LV current is over setting value, the voltage will be cut of... -
China High Quality flash point tester Supplier – GDND-800 Freezing Point Tester – HV Hipot
General Information 1. Transformer oil freezing point tester has the characteristics of exquisite structural design and unique manufacturing process. It conforms to GB/T 3535 and GB/T510 standards and is used to determine the pour point of petroleum products. 2. This instrument adopts compressor refrigeration technology to save energy, simple operation and long service life. Its main technical indicators such as cooling rate and cooling capacity have surpassed similar foreign products. Working conditions 1. The instrument should be placed on a flat and stable workbench, and air convection should be minimized in the environment. 2. This product may involve flammable materials when used. It is not allowed to have an open flame (or a device that produces spark) close to it during op... -
China High Quality power transformer and distribution transformer Factories – Partial Discharge Online Monitoring System of GIS – HV Hipot
General Information Gas-insulated metal-enclosed switches (GIS) and gas-insulated metal-enclosed transmission lines (GIL) are one of the most important devices in the power system. They have the dual tasks of control and protection. If they failed during operation and the problem cannot be solved timely,it will cause serious damage to the grid. Partial discharge fault is a common fault type of GIL/GIS. It is necessary to use GIS partial discharge online monitoring and fault location system to perform real-time online monitoring of GIL/GIS partial discharge signals and analyze and process the measured data and real time give comprehensive judgment of insulation status. Then repair schedule can be arranged according to the monitoring results to avoid major grid accidents caused by equi... -
OEM Best Impulse Voltage Test System Suppliers – GDCY-300kV/30kJ Impulse Voltage Test System – HV Hipot
Application This impulse test system is used for carrying out full wave lightning impulse voltage tests on HV apparatus such as clearance, bushings, capacitors, switches, power transformers(capacity below 5000kVA), CT/PT at 35kV or below. Operating Condition ● Altitude: 1000m. ● Ambient Temperature: -5℃~+45℃. ● Max. daily difference temperature: ≤25℃. ● Relative humidity: <90%. ● Anti-shock ability: ≤ level 7. ● Horizontal acceleration of the ground: 3.0m/s2, Vertical acceleration of the ground: 1.5m/s2. ● Waveform of power supply voltage wave is sine actually, and the waveform distortion rate<3%. ● It should be grounded reliably, ground resistance <0.5Ω. ● Usage environment: indoor. No conductive dust, No fire and explosion, No corrosive metal and insulation gas. Applied Sta... -
OEM Best Capacitance And Dissipation Factor Test Supplier – Partial Discharge Test System GDYT series – HV Hipot
GIT Series GIS High Voltage Test Sets integrate the high voltage boosting, high voltage measurement, high voltage transformer, high voltage coupling capacitors and all components in a sealed space. There are two modes to generate high voltage 1) Using reactor inductance and test object capacitance to realize voltage resonance test, to obtain a high voltage, high current from test object. 2) The other one is to obtain required high voltage directly from high voltage transformer. It is widely used for high voltage, big capacity GIS power equipment insulated withstand voltage test, partial discharge test and GIS transformer accuracy test, suitable for GIS substation, GIS power equipment manufacturer, basin type electrical insulator manufacturer. Features ● The High voltage o... -
China High Quality digital earth resistance tester price Manufacturers – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot
General Information GDCR1000C, GDCR1000D non-contact phase tester is a major breakthrough in traditional phase sequence detection method. The traditional phase sequence detection is to strip the connection pole of three-phase wires, connect three bare clamps or test needles of phase sequence meter to three bare fire lines, while GDCR1000C and GDCR1000D adopt pincers non-contact induction measurement. The phase sequence can be detected by no need peeling off the wire and without touching the bare high-voltage fire wire, just directly clamping three super-inductive high-insulation clamps on the insulation skin of the three-phase fire wire respectively. At the same time, acousto-optic indication of the positive or reverse phase state of the phase sequence of the three-phase power supply... -
China High Quality Current Injection Test Box Manufacturers – GDSL-A Seriese Automatic Primary Current Injection Test Set – HV Hipot
Features ● Built-in high configuration industrial control computer, the programmable logic controller (PLC) as the central processor, real-time scan of AC signal, to achieve comprehensive monitoring and closed-loop control, and design password settings management, only the personnel who gets corresponding operation authority, can carry out operation of certain functions. ● Color LCD touch screen. Using intelligent sensor based on field bus technology and realize the full digital data transmission, display operation unit is touch type color LCD screen, full English menu, the interface is clear and intuitive, the operation is simple and convenient. Test without any auxiliary equipment, automatic control, fast, simple and convenient. ● Automatic and manual test mode, with automatic cons... -
China High Quality Purity Test Factories – GDP-311PCAW 3-in-1 SF6 Quality Analyzer – HV Hipot
General Information GDP-311PCAW SF6 gas quality analyzer is a portable device designed to measure SF6 gas purity, dew point, composition, CF4 content and air content. The core component with NDIR sensor produced by European sensor company to test SF6 gas purity, RC sensor produced by Vaisala, Finland to test dew point, NDIR sensor produced by Smartgas, Germany to test SF6 gas decomposition product–CF4. the air sensor adopts itg technology. Besides, we also adopt professional hardware chips and excellent software algorithms of STMicroelectronics. Application ● SF6 analysis fo power system ● SF6 gas cylinder gas quality test ● Quality test of SF6 gas for recovery and reuse ● High purity gas manufacturing ● Semiconductor industry dry gas supply ● Research and development use ... -
China High Quality Types Of Primary Current Injection Tests Supplier – GDHL-100B Contact Resistance Tester (Microhm Meter) – HV Hipot
Description The performance of the conductive circuit of the circuit breaker is important to ensure the safe operation of the switch. The pros and cons of the conductive performance can be reflected by the size of the resistance of the conductive loop. Therefore, the IEC standard and the manufacturer have stipulated that the loop resistance should be measured, and there are clear specifications for the loop resistance of various types of switches. The loop resistance tester is a testing instrument meets the requirements of GB50150-2006 and DL / T 845.4-2004 regulations. It is widely applicable to the measurement of contact resistance, loop resistance, cable, wire, and weld contact resistance of various electrical switches. Application ● High,middle and low voltage circuit breakers... -
OEM Best DIGITAL PD DETECTOR Factory – Partial Discharge Online Monitoring System of Generators – HV Hipot
General Information Generally, partial discharge occurs at a position where the properties of the dielectric material are not uniform. At these locations, the local electric field strength is enhanced, and local electric field strength is too large, resulting in local breakdown. This partial breakdown is not the total breakdown of the insulating structure. Partial discharges typically require a certain amount of gas space to develop, such as gas voids inside the insulation, adjacent conductors, or insulating interfaces. When the local field strength exceeds the dielectric strength of the insulating material, a partial discharge occurs, causing many partial discharge pulses to occur during one cycle of applying the voltage. The amount of discharge delivered is closely related to the n... -
China High Quality oil testing machine Manufacturers – GDZL-50L Oil Filtration Machine – HV Hipot
General Information The machine GDZL-50L can effectively remove moisture, gas and impurities in the insulating oil, improve the pressure resistance of the oil and the quality of the oil, to ensure the safe operation of the power equipment. It is mainly used in the power sector and industrial and mining enterprises to deal with unqualified transformer oil, transformer oil, switch oil and so on. Features ● Small size and high efficiency, easy to move. It is especially suitable for live working on site. It also can dry the moisture of power equipment, and conveniently vacuum the power equipment. ● Infrared liquid level automatic control device, system pressure automatic protection device and high-efficiency degassing components are adopted in the structure. The operation is convenient and ... -
OEM Best insulation resitance transformer Factory – Substation Temperature Monitoring System – HV Hipot
General Information There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. As long as the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be f...