Featured

  • China High Quality insulation testing Supplier –  Partial Discharge Online Monitoring System of Generators – HV Hipot

    China High Quality insulation testing Supplier – Partial Discharge Online Monitoring System of Generators – HV Hipot

    General Information Generally, partial discharge occurs at a position where the properties of the dielectric material are not uniform. At these locations, the local electric field strength is enhanced, and local electric field strength is too large, resulting in local breakdown. This partial breakdown is not the total breakdown of the insulating structure. Partial discharges typically require a certain amount of gas space to develop, such as gas voids inside the insulation, adjacent conductors, or insulating interfaces. When the local field strength exceeds the dielectric strength of the insulating material, a partial discharge occurs, causing many partial discharge pulses to occur during one cycle of applying the voltage. The amount of discharge delivered is closely related to the n...
  • China High Quality Capacitor Power Supplier –  AC High Voltage Test Sets for GIS – HV Hipot

    China High Quality Capacitor Power Supplier – AC High Voltage Test Sets for GIS – HV Hipot

    Applications  ● Transformer ● GIS system ● SF6 switchgear ● Cables ● Bushing ● Insulator ● CT/PT ● Other capacitive devices Features ● Small temperature rises at rated load. Dry or Oil type reactors, high mechanical strength, good insulation, nice and reliable. ● Adjustable capacity of frequency control source. Strong protection, good stability. With multiple working mode, easy to operate. ● With 220V or 380V single phase power, convenient for on-site power sourcing. ● Flexible configuration. Different type reactors for optional, meet different test object requirements. Multifunctional, cost effective. Specifications ● Rated output voltage: based on different test objects. ● Output frequency: 20- 300Hz. ● Waveform: pure sine wave, THD <1.0%. ● Max. capacity: 1000kVA and belo...
  • China High Quality Type Test Circuit Breaker Factory –  GMDL-02A HV Circuit Breaker Analog Device – HV Hipot

    China High Quality Type Test Circuit Breaker Factory – GMDL-02A HV Circuit Breaker Analog Device – HV Hipot

    General Information GMDL-02A high-voltage circuit breaker simulation device is manufactured using the principles of large-scale field programmable gate arrays, power electronic devices with protection, etc. The open coil is designed according to an independent loop, which can simulate the three-phase and split-phase operation of the voltage level of 6-110KV. The action behavior of the single open coil circuit breaker is suitable for the selection of power systems, industrial and mining enterprises, scientific research institutes, professional colleges, and protection manufacturers. It is used as a substitute for actual circuit breakers in the transmission test of the entire system of relay protection and automatic devices with switches. The action is accurate, reliable, and the numbe...
  • OEM Best Cable Fault Tester Manufacturer –  GD-4136H Cable Fault Locating System  – HV Hipot

    OEM Best Cable Fault Tester Manufacturer – GD-4136H Cable Fault Locating System – HV Hipot

    GD4136H Cable Fault system is an important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1.GD-2131H Impulse Generator 2.GD-4132 Cable Fault Locator 3.GD-4133 Multi-pulse Cable Fault Detector 4.GD-4133S Multi-pulse Coupler 5.Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-4133 Cable Fault Tester, there are two locating ways: a. Low vol...
  • OEM Best Insulation Resistance Tester Manufacturers Supplier –  GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot

    OEM Best Insulation Resistance Tester Manufacturers Supplier – GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot

    Adoption of Standard ● DL/T 596-2005 “Procedure Test Procedures for Electrical Equipment” ● GB1094.1-GB1094.6-96 “Shell protection level” ● GB2900 “Electrical Terminology” ● GB/T16927.1~2-1997 “High Voltage Test Technology” ● GB4793-1984 “Safety Requirements for Electronic Measuring Instruments” ● GB191 “Package Storage and Transportation Mark” ● GB/T.311-1997 “Insulation and coordination of high voltage power transmission and transformation equipment” Features ● Using high conductivity copper as the output electrode, the contact surface is large and the flow capacity is strong. ● Brushed aluminum plate with a new process, simple and eye-catching, wear-resistant and pollution-resistant. ● The all-...
  • China High Quality Ct Transformer Manufacturers –  GDHG-201P CT/PT Analyzer – HV Hipot

    China High Quality Ct Transformer Manufacturers – GDHG-201P CT/PT Analyzer – HV Hipot

    Features ● Full function and can satisfy all kinds of CT (protection CT, measuring CT, TP) test requirements, such as excitation characteristic test, turn ratio, polarity, secondary winding resistance, secondary burden, ratio error, angular difference and etc. Also can used to test excitation characteristic, turn ratio, polarity, secondary winding resistance, ratio error, angular difference and etc of all kinds of PT. ● Field verification of CT does not require standard current transformers, current injector, load bank, voltage regulating controller and large current cables. Very simple test wiring and operation are used to realize the current transformer verification, which greatly reduces the work intensity and improves the work efficiency, and facilitates the field verification of...
  • China High Quality insulation testing megger Supplier –  Dielectric Loss Tester for Live Capacitive Equipment GDDJ-HVC  – HV Hipot

    China High Quality insulation testing megger Supplier – Dielectric Loss Tester for Live Capacitive Equipment GDDJ-HVC – HV Hipot

    General Information There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. If the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be found in ...
  • China High Quality Routine Test Of Circuit Breaker Factory –  GMDL-02A HV Circuit Breaker Analog Device – HV Hipot

    China High Quality Routine Test Of Circuit Breaker Factory – GMDL-02A HV Circuit Breaker Analog Device – HV Hipot

    General Information GMDL-02A high-voltage circuit breaker simulation device is manufactured using the principles of large-scale field programmable gate arrays, power electronic devices with protection, etc. The open coil is designed according to an independent loop, which can simulate the three-phase and split-phase operation of the voltage level of 6-110KV. The action behavior of the single open coil circuit breaker is suitable for the selection of power systems, industrial and mining enterprises, scientific research institutes, professional colleges, and protection manufacturers. It is used as a substitute for actual circuit breakers in the transmission test of the entire system of relay protection and automatic devices with switches. The action is accurate, reliable, and the numbe...
  • OEM Best price of lt&ht megger Manufacturer –  GD2000D Insulation Resistance Tester – HV Hipot

    OEM Best price of lt&ht megger Manufacturer – GD2000D Insulation Resistance Tester – HV Hipot

    General Information GD2000D digital insulation resistance tester produced by our company uses an embedded industrial single chip real-time operating system. The digital analog pointer and digital field code display are perfectly combined. This series of meters has a variety of voltage output levels (250V, 500V, 1000V, 2500V, 5000V, 10000V), large capacity, strong anti-interference, analog pointer and digital synchronous display, AC and DC dual-use, simple operation, automatic calculation of various insulation indicators (absorption ratio, polarization index), various measurement results with anti-power-down function, etc. It is an ideal test instrument for measuring the insulation resistance of large-capacity transformers, transformers, generators, high-voltage motors, power capacito...
  • China High Quality Capacitance Meter Factories –  AC Dielectric Test Equipment with manual control unit GDYD-M – HV Hipot

    China High Quality Capacitance Meter Factories – AC Dielectric Test Equipment with manual control unit GDYD-M – HV Hipot

    Application AC Hipot testing is the effective and direct way to test insulation strength for electric equipment, apparatus, or machines. It checks dangerous flaws which assure electric equipment continuous working. Typical applications include testing of transformers, switchgear, cables, capacitors, aerial motors platforms, hot sticks bucket bricks, vacuum bottles and other related equipment like vacuum interrupters, blankets, ropes, gloves, hydraulics hose, instruments transformers generators. Features ● Pointer display panel mounted controls & indicators with easy-to-read legend. ● Monitoring high voltage side voltage, low voltage side current and indicator of zero, power, working start, timing. ● Over-current protection, zero-starting protection, sound, and light alarm. ● C...
  • OEM Best Universal Relay Tester Factory –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot

    OEM Best Universal Relay Tester Factory – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot

    Features A. Working conditions 1. Power supply: AC 220V±10%,50Hz 2. Working environment: Temperature -10℃~40℃; Humidity: ≤85% 3. Atmosphere: 86-106kPa B. Output power supply 1. AC voltage: 0-220V/3A  Adjustable 2. AC current: 0-100A/7V (200A can be customized);  0-20A/25V  Adjustable; 0-5A/5V  Adjustable 3. DC voltage: 0-220V/3A  Adjustable 4. DC current:0-20A/25V 5. Fixed voltage output: DC 24V/48V/110V/220V 6. Current/Voltage accuracy: ±1%. C. Performance Index 1. Ammeter and voltmeter: 41/2 digit. 2. Digital millisecond meter: 0-99.9999s(999.999s can be customized) Resolution: 0.1ms. D. Functions 1. Measure relay: Measure start value, return value and drop-off to pick-up ratio of current, voltage relay. 2. Time relay: Measure start value, return value and action time. 3. Intermed...
  • China High Quality Ct & Pt Analyzer Factory –  GDHG-108A CT/PT Tester – HV Hipot

    China High Quality Ct & Pt Analyzer Factory – GDHG-108A CT/PT Tester – HV Hipot

    GDHG-108A CT/PT Tester supports test voltage method to test bushings CTs which installed on transformer or inside switch-gear, suitable for the laboratory and on-site detection. Itcan be easily and conveniently done voltage current characteristic, transformer ratio, ratio and phase angle error, load test items on CT/PT. Features ● Using the voltage detection principle to measure CT and PT. ● To meet the requirements of GB1207, GB1208, GB168-47 (IEC60044-1.6) and other standards. ● No external auxiliary equipment, a single machine can complete all test items. ● With high speed micro printer: real-time print the test result. ● Using intelligent controller, operation is simple. ● 5inch LCD screen display. ● Automatically given CT/PT (excitation) knee point value. ● Auto display 5% and 1...