Featured

  • China High Quality Use Of Coupling Capacitor Manufacturer –  Partial Discharge Test System GDYT series – HV Hipot

    China High Quality Use Of Coupling Capacitor Manufacturer – Partial Discharge Test System GDYT series – HV Hipot

    GDYT is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities. It includes below components 1. Hipot Test Control Unit GDYD       2. PD-free Gas type transformer YDQW   3. Coupling capacitor       4. Protective resistor              5. Isolation filter LBQ                    6. Partial discharge detector  Features ● Advanced PD-free epoxy insulating tube, small partial discharge capacity. ● Low impedance voltage, better than national standard. ● Automatic co...
  • China High Quality Ht Cable Testing Manufacturers –  GD-7018A Optical Fiber Identifier – HV Hipot

    China High Quality Ht Cable Testing Manufacturers – GD-7018A Optical Fiber Identifier – HV Hipot

    The GD-7018 series optical fiber pipeline identifier can accurately locate and meaure depth of the underground pipelines, cables and optical cables under the condition of without digging, and accurately find the damage points of the outer coating of the underground pipelines and the location of the underground cable fault points. The instrument incorporates the most advanced technologies such as ultra-narrow band filter, Bluetooth wireless communication, GPS positioning, automatic data mapping by professional data analysis software and automatic generation of test reports. The detection and inspection of various kinds of metal pipelines, pipeline management and maintenance, municipal planning and construction, pipeline inspection in power supply and other departments is one of the neces...
  • China High Quality High Power Pulse Generator Manufacturer –  GDCL-20kV/10kA Impulse Combination Wave Test System Technical Solution – HV Hipot

    China High Quality High Power Pulse Generator Manufacturer – GDCL-20kV/10kA Impulse Combination Wave Test System Technical Solution – HV Hipot

    Application The equipment is according to combination wave testing requirement of the low-voltage power distribution system SPD II product, enable to generate impulse voltage (1.2/50μs) and impulse current (8/20μs), is used for grade III test and limiting voltage test of SPD and components. It is also used for impulse current test and residual voltage test of the MOV valve plate, unit and surge protective device(SPD), or used in other scientific research experiments. The device uses touch screen and PLC control technology, and the main performance meets the needs of domestic and foreign SPD products and their components for various combination wave testing. Standards ● GB 18802.1-2012 GB 18802.1-2012 Surge protective devices connected to low-voltage power distribution systems Par...
  • China High Quality DIGITAL PD DETECTOR Suppliers –  GDPD-313M Portable Partial Discharge Detector – HV Hipot

    China High Quality DIGITAL PD DETECTOR Suppliers – GDPD-313M Portable Partial Discharge Detector – HV Hipot

    External flexible sensor (for option) Parabolic sensor (wave condenser, for option) TEV and AE method is acknowledged and suitable technology to be used in online partial discharge detection. GDPD-313M uses ultrasonic detection technology (AE) and TEV mode, which can effectively ensure signal sensitivity in the interference on-site environment. It is suitable to detect PD flaw and locate PD signal for switch cabinet etc. Features ● Built-in ultrasonic sensor. electrical fault generates ultrasonic wave at the fault point, and ultrasonic mode transmits the ultrasonic signal through the earphone to scan the area to detect the discharge. Various characteristics of vibration, pop, and hum can be associated with different faults. ● Built-in high-precision TEV sensor, coupled with electrom...
  • OEM Best Vlf High Voltage Suppliers –  30kVA.200kV Automatic AC.DC Hipot Test Set GDYD-2030A – HV Hipot

    OEM Best Vlf High Voltage Suppliers – 30kVA.200kV Automatic AC.DC Hipot Test Set GDYD-2030A – HV Hipot

    Features ● 7inch color LCD screen, with PLC automation control. ● HV Voltage, LV voltage, LC current measured at the same time, with high precision sensor and high-performance collection chip. ● Automatic mode and manual mode for option. ● Display HV voltage, LV voltage, LV current, time, and withstanding result. ● Over-voltage and over-current protection. Output voltage, HV current upper limit, LV current upper limit and timing can be set. ● Zero-starting function. Test can be proceeded after the voltage is back to zero. ● Store up to 8000pcs data in 3months. It has USB port to upload data to USB disk. ● When setting voltage is arrived, it will be timing automatically. After timing, voltage will be back to zero. ● When the LV current is over setting value, the voltage will be cut of...
  • OEM Best Unit Of Measurement Of Capacitance Manufacturers –  AC Dielectric Test Equipment with manual control unit GDYD-D – HV Hipot

    OEM Best Unit Of Measurement Of Capacitance Manufacturers – AC Dielectric Test Equipment with manual control unit GDYD-D – HV Hipot

    Application Features ● Digital (Pointe) display panel mounted controls & indicators with easy-to-read legend. ● Monitoring high voltage side voltage, low voltage side current and indicator of zero, power, working start, timing. ● Over-current protection, zero-starting protection, sound, and light alarm. ● Continuously variable output from zero to full voltage. ● Adjustable over current protection, with trip levels variable from 10 to 110%. ● With new type time relay, time range is wider (1S ~ 99H). ● Using the latest current relay, more accurate and reliable. ● Light weight, small size, easy to move. Technical Specifications ● Input voltage: AC 220V or 380V ● Output voltage of control unit: AC 0-250V or 0-430V ● Output current of control unit:0-5/10/15/50A(customized) ● Ca...
  • OEM Best Ht 32 Kv Ht Cable Fault Detector Turkey Exporters –  GD-4136H Cable Fault Locating System  – HV Hipot

    OEM Best Ht 32 Kv Ht Cable Fault Detector Turkey Exporters – GD-4136H Cable Fault Locating System – HV Hipot

    GD4136H Cable Fault system is an important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1.GD-2131H Impulse Generator 2.GD-4132 Cable Fault Locator 3.GD-4133 Multi-pulse Cable Fault Detector 4.GD-4133S Multi-pulse Coupler 5.Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-4133 Cable Fault Tester, there are two locating ways: a. Low vol...
  • China High Quality digital insulation tester Supplier –  GDCR1000C Non-contact Phase Sequence Tester – HV Hipot

    China High Quality digital insulation tester Supplier – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot

    General Information GDCR1000C, GDCR1000D non-contact phase tester is a major breakthrough in traditional phase sequence detection method. The traditional phase sequence detection is to strip the connection pole of three-phase wires, connect three bare clamps or test needles of phase sequence meter to three bare fire lines, while GDCR1000C and GDCR1000D adopt pincers non-contact induction measurement. The phase sequence can be detected by no need peeling off the wire and without touching the bare high-voltage fire wire, just directly clamping three super-inductive high-insulation clamps on the insulation skin of the three-phase fire wire respectively. At the same time, acousto-optic indication of the positive or reverse phase state of the phase sequence of the three-phase power supply...
  • OEM Best Discharge Capacitor With Multimeter Supplier –  DC High Voltage Generator GDZG-300 – HV Hipot

    OEM Best Discharge Capacitor With Multimeter Supplier – DC High Voltage Generator GDZG-300 – HV Hipot

    Features ● Simple operation and complete function, easy for wild work. ● Higher voltage stability, smaller ripple coefficient. ● More reliable and stable, continuous short-circuit discharge directly to ground. ● Intelligent grounding protection and alarm function. High precision, accurate measurement, digital display of voltmeter and ammeter, with voltage resolution 0.1kV, and current 0.1uA. ● High stability of voltage regulation, smooth voltage boosting process, high adjustable precision, with coarse and fine adjustment functions. Accuracy of voltage regulation better than 0.1%, voltage and current measurement error is less than 1.0%, ripple factor better than 0.5%. ● With function of high-accuracy 75%VDC-1mA, more convenient for zinc oxide lighting arrester DC testing. ● HV booste...
  • OEM Best Gas Purity Check Factories –  GDPDS-341 SF6 Electrical Insulation State Comprehensive Analyzer – HV Hipot

    OEM Best Gas Purity Check Factories – GDPDS-341 SF6 Electrical Insulation State Comprehensive Analyzer – HV Hipot

    General Information At present, the UHV voltage level of 110KV and above uses SF6 gas-insulated enclosed GIS as the main primary equipment of the substation, the evaluation of GIS internal insulation status is mainly achieved by partial discharge detection method and SF6 gas chemical analysis method at home and abroad. When partial discharge occurs in the early stage of insulation degradation inside the GIS, it will cause serious safety hazards to its safe operation. The detection methods of partial discharge mainly include three methods: ultra-high frequency partial discharge test, ultrasonic partial discharge test, and chemical detection of SF6 gas composition. At present, there are separate devices for these types of test methods on the market. For on-site GIS partial discharge li...
  • China High Quality Circuit Breaker Timing Test Equipment Manufacturer –  GDHL-200A (GDHL-100A) Micro-Ohmmeter new – HV Hipot

    China High Quality Circuit Breaker Timing Test Equipment Manufacturer – GDHL-200A (GDHL-100A) Micro-Ohmmeter new – HV Hipot

    General Information GDHL-200A (GDHL-100A) Micro-Ohmmeter is widely used to measure loop resistance and contact resistance for weld joints, cables, and various HV switches within power industry. It uses intelligent power test system “Smart-Quick”, which is granted software copyright, and advanced detection technology. Features ● Adopt high-precision constant current power supply, automatic rising current mode without manual adjustment, the test is fast and accurate. ● Use four-terminal wiring method, effectively eliminate the interference produced by test cable resistance. ● Wide range, high accuracy, the resistance measurement range is up to 99mΩ. ● At 200A, max. test time can reach 1~999s, which meets various on-site applications. ● Large current output for a long tim...
  • China High Quality Test power meter Manufacturers –  GDPQ-5000 Power Quality Analyzer – HV Hipot

    China High Quality Test power meter Manufacturers – GDPQ-5000 Power Quality Analyzer – HV Hipot

    Introduction GDPQ-5000 Power Quality Analyzer is a comprehensive test instrument carefully developed by our company and specially designed for field test of three phases, multi-functional and intelligent, concise man-machine operation. It is easy to use, large LCD screen display, high resolution, interface in both Chinese and English, shock-proof shell structure and so on. Can simultaneously measure the 4-channel current (ABC three phase and neutral wire current), 4-channel voltage (ABC three-phase voltage and neutral line voltage to ground), the peak value of current voltage, maximum/minimum value over a period, three-phase imbalance factor, short-time voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor and displacement power factor, act...

Send your message to us:

Write your message here and send it to us