China High Quality Underground Cable Fault Detector Supplier – GD-7018A Optical Fiber Identifier – HV Hipot
The GD-7018 series optical fiber pipeline identifier can accurately locate and meaure depth of the underground pipelines, cables and optical cables under the condition of without digging, and accurately find the damage points of the outer coating of the underground pipelines and the location of the underground cable fault points. The instrument incorporates the most advanced technologies such as ultra-narrow band filter, Bluetooth wireless communication, GPS positioning, automatic data mapping by professional data analysis software and automatic generation of test reports. The detection and inspection of various kinds of metal pipelines, pipeline management and maintenance, municipal planning and construction, pipeline inspection in power supply and other departments is one of the neces... -
OEM Best relay testing companies Factory – GDJB-802 3 Phase Secondary Current Injection Relay Test Set – HV Hipot
General Information GDJB-802 3 Phase Secondary Current Injection Relay Protection Test Device plays a key role in operating electricity power systems reliably and safely. It can automatically judge over-current, over-voltage, overload, short circuit, high temperature, abnormal data and warning prompts for misoperation. In addition to the verification of various relays (such as current, voltage, inverse time, power direction, impedance, differential, low cycle, synchronization, frequency, DC, intermediate, time, etc.) and microcomputer protection, it can also simulate single-phase to Three-phase transient, permanent, and transitional faults are tested for the entire set. It can also complete various large-scale and complex calibration tasks with a high degree of automation, can automa... -
China High Quality Capacitor A Exporters – AC Dielectric Test Equipment with manual control unit GDYD-D – HV Hipot
Application Features ● Digital (Pointe) display panel mounted controls & indicators with easy-to-read legend. ● Monitoring high voltage side voltage, low voltage side current and indicator of zero, power, working start, timing. ● Over-current protection, zero-starting protection, sound, and light alarm. ● Continuously variable output from zero to full voltage. ● Adjustable over current protection, with trip levels variable from 10 to 110%. ● With new type time relay, time range is wider (1S ~ 99H). ● Using the latest current relay, more accurate and reliable. ● Light weight, small size, easy to move. Technical Specifications ● Input voltage: AC 220V or 380V ● Output voltage of control unit: AC 0-250V or 0-430V ● Output current of control unit:0-5/10/15/50A(customized) ● Ca... -
OEM Best Earth Resistance Measurement Factories – GDHL-100A Micro-Ohmmeter – HV Hipot
General Information GDHL-100A Micro-Ohmmeter is widely used to measure loop resistance and contact resistance for weld joints, cables, and various HV switches within power industry. It uses intelligent power test system “Smart-Quick”, which is granted software copyright, and advanced detection technology. Features ● Adopt high-precision constant current power supply, automatic rising current mode without manual adjustment, the test is fast and accurate. ● Use four-terminal wiring method, effectively eliminate the interference produced by test cable resistance; ● Wide range, high accuracy, the resistance measurement range is up to 99mΩ. ● Multiple test times can be set, which meets various on-site applications; ● Large current output for a long time, burning the switch ... -
OEM Best soil resistivity testing methods Suppliers – GDCR3200C Double Clamp Multifunctional Earth Resistance Tester – HV Hipot
General Information GDCR3200C Double Clamp Multifunctional Earth Resistance Tester is specially designed and manufactured for on-site measurement of grounding resistance, soil resistivity, grounding voltage, grounding line leakage current, AC current and DC resistance. The instrument adopts advanced digital processing technology, with 2-wire method, 3-wire method, 4-wire method, selection method, double clamp method and other measurement methods; Import FFT (Fast Fourier Transform) technology, AFC (Automatic Frequency Control) technology, with unique anti-interference ability and environmental adaptability, high repeated test consistency, ensuring high precision, high stability and high reliability for long-term measurement.The instrument used large caliber current clamp design, can ... -
China High Quality Underground Cable Fault Detection Supplier – GDCF-900T Vehicle Mounted Cable Fault Locating System – HV Hipot
Vehicle Mounted Cable Fault Locator system is used for Cable Fault conditioning (burn-down), Pre-Location, Route Location, Pin-pointing & Testing of HV & LV cables of different types&sizes. The set is suitable to carrying out the above-mentioned multifunction on power cables of various voltage levels mainly 33KV, 11KV, 415V and control cables with 1.1 KV grade. The set shall be used for cable types namely XLPE, PVC, PILC with Al / Cu conductor. The cables are laid underground (under plain earth, trenches, or RCC surface, Horizontal Drilling in HDD Pipe), above ground or partly under & partly above ground with maximum cable length around 25Km. The cable fault locator is suitable for fault locating and pinpointing the following types of cable faults. ● High resistance ● L... -
OEM Best Capacitor Is Measured In Factories – AC Inductance Resonance Test System for CVT – HV Hipot
GDTL AC Resonant Test System for CVT is series resonance with power frequency specially for CVT. It is smaller size and more lighter weight than traditional device, meet various CVT inspection requirements of voltage with 35kV, 66kV, 110kV, 220kV, 330kV, 500kV. According to customer’s requirement, the reactor can be divided into fixed and adjustable reactor. Features ● Small size, light weight, simple wiring. ● Dry or Oil type reactor, high mechanical strength, good insulation, high reliability. ● Large capacity margin, good output waveform, easy to operate. ● Fully protection function: zero protection, over-voltage protection, over-current protect functions. -
China High Quality Sf6 Gas Leak Detection And Analysis Factories – GDFJ-311M SF6 Gas Decomposition Product Tester – HV Hipot
General Information GDFJ-311M SF6 Gas Decomposition Product Tester is a portable device designed to measure SF6 gas decomposition product. The core component with electrochemical sensor from Membrapor to test SF6 gas decomposition product. Besides, we also adopt professional hardware chips and excellent software algorithms of STMicroelectronics. Application Decomposition product analysis of SF6 gas insulated electrical equipment Quality detection of recycled SF6 gas R&D use Reference standard DL/T 639-1997: Safety and Protection Guide for Operation Test and Maintenance Personnel of SF6 Electrical Equipment. Guodian No.72 Annex 3[1999] Measures for Quality Supervision and Management of High Voltage Switchgear. GB/T 17626: Electro-magnetic Compatibility – Testing and M... -
OEM Best transformer insulation resistance test Suppliers – GDJF-2008 Partial Discharge Analyzer – HV Hipot
GDJF-2008 Partial Discharge Detector is measuring partial discharge for the products such as transformers, mutual inductors, HV switches, zinc monoxide arresters and power cables. It also can make type tests and monitor insulation operation. This type has the advantages of high sensitivity, wide range of capacitance, being well equipped for input unit impedance detecting and more variants of frequency bands (9 in all). After proper setting, the discharge impulse amount can be read directly. The indicating and digital meters are shown simultaneously. This detector is widely applied in power stations, manufacturers, and institutions. Use Condition ● Ambient temperature: 0-40℃±2℃. ● Relative humidity: ≤80% ● Power supply: 220V±10%, 50HZ. ● No violent vibration and mechanical shock. ● Th... -
OEM Best Miniature Circuit Breaker Mcb Supplier – GDHL-100HS 100A Handheld Contact Resistance Tester – HV Hipot
General Information The product is mainly used for the contact resistance of switch contacts and other micro-ohm resistance measurement, and the test speed is fast and the accuracy is high. This handheld contact resistance tester is an innovative product that is compact, hand-held, battery powered and easy to carry. Features ● Maximum output current is 100A, two current levels are selectable ● Built-in large capacity lithium battery, it can perform more than 600 tests on one charge. ● The test is simple, the operation is convenient, and it can work continuously for more than 8 hours. ● In the 100A test, the longest test time can be up to 60 seconds, which can meet various usage scenarios on site. ● Wide range, high precision, up to 10mΩ at 100A. ● With complete protection functio... -
China High Quality megger insulation test Manufacturers – GDWR-5A Earth Resistance Tester for Ground Grid – HV Hipot
Product Description GDWR-5A Earth Resistance Tester is a high-precision test instrument used in various fields such as substations for testing grounding resistance and related parameters. The instrument has the characteristics of small volume, light weight, convenient carrying, strong anti-interference performance and high accuracy. The instrument is an integrated structure, built-in variable frequency power supply module, and the output power supply is continuously variable frequency adjustable. The frequency can be changed to 45Hz or 55Hz, and the built-in high-speed processor core adopts high-end digital filtering technology, which effectively avoids the interference of the power frequency electric field to the test, and fundamentally solves the problem of accurate measurement und... -
OEM Best lightning protection installation Supplier – GDUD-PTM Ultrasonic Flaw Detector for Electrical Power Tower – HV Hipot
Features ● TFT true color screen. ● Using leading embedded digital system technology, the electrical performance indicators of the instruments are designed and manufactured according to the standard EN 12668.1 – 2000. ● Advanced and safe lithium polymer battery and power management technology, automatic alarm and protection. The automatic standby screen saver can be set to make the equipment more energy-efficient and longer-lasting, and to ensure continuous and efficient flaw detection. ● Application software that integrates intelligent and powerful processing functions, direct-reading user interface and operation mode, or digital knob one-button operation mode. ● Large-capacity detection parameters preset channel, convenient for users to operate on different detection objects...