Featured

  • China High Quality Capacitors Uses Factory –  GDZJ-30S Turn-to-Turn Surge Withstand Tester – HV Hipot

    China High Quality Capacitors Uses Factory – GDZJ-30S Turn-to-Turn Surge Withstand Tester – HV Hipot

    General Information Specifications Input voltage 220V±5%; frequency 50/60Hz±2% Measurement range 0-30kV, continuous adjustment, ±5% Trigger times 6.25 time/s - 50 times/s Waveform rising time 0.1-0.5μS Capacitance error (+0.3) / (-0.1) µs Impulse capacitance 0.01μF -0.1μF Max output energy 60J Power consumption 1000VA Insulation resistance Insulation resistance between power input terminal and tester ≥20MΩ Dielectric strength 1500V/50Hz at 1min, there is no flashing and breakdown for withstand voltage test. Temperature 0-40 degree Relative humidity ≤80% at 40 degree Waveform capacitance deviation ±3% Dimension 650*550*1700mm Weight 100kg Application Turn to turn withstand voltage test ...
  • China High Quality High Voltage Cap Manufacturer –  DC High Voltage Generator GDZG-300 – HV Hipot

    China High Quality High Voltage Cap Manufacturer – DC High Voltage Generator GDZG-300 – HV Hipot

    Features ● Simple operation and complete function, easy for wild work. ● Higher voltage stability, smaller ripple coefficient. ● More reliable and stable, continuous short-circuit discharge directly to ground. ● Intelligent grounding protection and alarm function. High precision, accurate measurement, digital display of voltmeter and ammeter, with voltage resolution 0.1kV, and current 0.1uA. ● High stability of voltage regulation, smooth voltage boosting process, high adjustable precision, with coarse and fine adjustment functions. Accuracy of voltage regulation better than 0.1%, voltage and current measurement error is less than 1.0%, ripple factor better than 0.5%. ● With function of high-accuracy 75%VDC-1mA, more convenient for zinc oxide lighting arrester DC testing. ● HV booste...
  • China High Quality oil testing equipment Manufacturer –  GDW-106 Oil Dew Point Tester User’s Guide – HV Hipot

    China High Quality oil testing equipment Manufacturer – GDW-106 Oil Dew Point Tester User’s Guide – HV Hipot

    Caution ● The following instructions are used by qualified person to avoid electrical shock. Do not perform any service beyond operation instructions unless you are qualified to do so. ● Don’t operate this device in flammable and moist environment. Keep the surface clean and dry. ● Please make sure the equipment is upright before opening. Don’t drop equipment heavily avoid equipment movement damage. ● Place the equipment in dry, clean, ventilated area free from corrosive gas. Stacking equipment without transit containers is dangerous. ● Panel should be upright during storage. Elevate stored items to protect from moisture. ● Don’t disassemble the instrument without permission, which will affect the warranty of the product. The factory is not responsible for self-dism...
  • China High Quality megger test electrical Manufacturers –  GD2000H 10kV Insulation Resistance Tester – HV Hipot

    China High Quality megger test electrical Manufacturers – GD2000H 10kV Insulation Resistance Tester – HV Hipot

    General Information This device can test insulation resistance (such as transformer, switchgear, leads, motor) of different modules in one system, to insulate and repair failure components. It is important to ensure products quality and security of person and equipment during operation by insulation test of checking test object to ground or adjacent conductors’ insulation. Before power on the system, use insulation test to verify if it is good to improve system performance. Insulation test is to find manufacturing process problems and equipment fault which can’t be found before failure happened. In EU, this test is compulsory, even to civil system. Features 1. Voltage output GD2000H (5kV/10kV).Resistance range 0-400GΩ. 2. Two modes display insulation resistance. 3. Aut...
  • China High Quality Capacitance Measuring Instrument Exporters –  AC Inductance Resonance Test System for CVT – HV Hipot

    China High Quality Capacitance Measuring Instrument Exporters – AC Inductance Resonance Test System for CVT – HV Hipot

    GDTL AC Resonant Test System for CVT is series resonance with power frequency specially for CVT. It is smaller size and more lighter weight than traditional device, meet various CVT inspection requirements of voltage with 35kV, 66kV, 110kV, 220kV, 330kV, 500kV. According to customer’s requirement, the reactor can be divided into fixed and adjustable reactor. Features ● Small size, light weight, simple wiring. ● Dry or Oil type reactor, high mechanical strength, good insulation, high reliability. ● Large capacity margin, good output waveform, easy to operate. ● Fully protection function: zero protection, over-voltage protection, over-current protect functions.
  • OEM Best interchangeable photocontroller relay tests Exporters –  GDJB-802 3 Phase Secondary Current Injection Relay Test Set – HV Hipot

    OEM Best interchangeable photocontroller relay tests Exporters – GDJB-802 3 Phase Secondary Current Injection Relay Test Set – HV Hipot

    General Information GDJB-802 3 Phase Secondary Current Injection Relay Protection Test Device plays a key role in operating electricity power systems reliably and safely. It can automatically judge over-current, over-voltage, overload, short circuit, high temperature, abnormal data and warning prompts for misoperation. In addition to the verification of various relays (such as current, voltage, inverse time, power direction, impedance, differential, low cycle, synchronization, frequency, DC, intermediate, time, etc.) and microcomputer protection, it can also simulate single-phase to Three-phase transient, permanent, and transitional faults are tested for the entire set. It can also complete various large-scale and complex calibration tasks with a high degree of automation, can automa...
  • China High Quality Ignition Coil Resistance Test Exporters –  GDKC-15 Series Circuit Breaker Analyzer 2020.12 – HV Hipot

    China High Quality Ignition Coil Resistance Test Exporters – GDKC-15 Series Circuit Breaker Analyzer 2020.12 – HV Hipot

    General Information High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-15 Series is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy.  GDKC-15 Series   GDKC-15A GDKC-15B GDKC-15C GDKC-15D GDKC-15E GDKC-15F GDKC-15G GDKC-15H Metal contact 12 12 12 12 12 12 12 12 Closing resistance   6 6 6 6 6 6 6 Graphite contact       3 3 3 3 6 Double-ended grounding         3 3 3 6 Dynamic resistance(Pre-insertion resistor) 1 1 3 3   3 3 6 Static resistance 1 1 3 3   3 3 6 Ground resistance             3 6 Features ● It is suitable for the mechanical test of all types of SF6 switches, GIS combination appliances, vacuum switches and oil switches. ● Strong an...
  • OEM Best High Voltage Cable Fault Locator Factories –  GD-2134A Cable Identifier – HV Hipot

    OEM Best High Voltage Cable Fault Locator Factories – GD-2134A Cable Identifier – HV Hipot

    The purpose of the cable identifier is to accurately identify one of the target cables from multiple cables and avoid serious accidents caused by wrong sawing of live cables. Cable identification starts from the operation of both ends of the cable, it must be ensured that the double number on both ends of the cable is accurate. GD-2134A Cable Identifier is only suitable for on-site identification of de-energized cables. It is strictly forbidden to connect the cable identifier to the running power cable! Features ● Handheld receiver automatically identify and display the results to ensure that the results of cable identification are 100% accurate. Light weight and powerful, easy to carry. ● Suitable for on-site identification of de-energized cables. ● Both transmitter and handheld re...
  • OEM Best Power Cable Fault Locator Manufacturers –  GD-2134E  Cable Identifier – HV Hipot

    OEM Best Power Cable Fault Locator Manufacturers – GD-2134E Cable Identifier – HV Hipot

    GD-2134E is a high-performance underground metal pipeline detection system composed of signal transmitters and receivers. It can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables. It can carry out uniqueness identification with a variety of selected accessories, as well as pipe insulation damage and the search for some types of cable faults. Features ● Compass display: intuitively displays the pipeline location and left & right directions. ● Tracking true and false prompts: current direction measurement, tracking correct error prompts, eliminating line interference (some frequencies). ● Depth and current measurements, can display the signal strength historical curve. ● Fully digital high-precision sampling processing: sta...
  • China High Quality Sf6 Analyzer Measures Purity Supplier –  GDFJ-311M SF6 Gas Decomposition Product Tester – HV Hipot

    China High Quality Sf6 Analyzer Measures Purity Supplier – GDFJ-311M SF6 Gas Decomposition Product Tester – HV Hipot

    General Information GDFJ-311M SF6 Gas Decomposition Product Tester is a portable device designed to measure SF6 gas decomposition product. The core component with electrochemical sensor from Membrapor to test SF6 gas decomposition product. Besides, we also adopt professional hardware chips and excellent software algorithms of STMicroelectronics. Application Decomposition product analysis of SF6 gas insulated electrical equipment Quality detection of recycled SF6 gas R&D use Reference standard  DL/T 639-1997: Safety and Protection Guide for Operation Test and Maintenance Personnel of SF6 Electrical Equipment. Guodian No.72 Annex 3[1999] Measures for Quality Supervision and Management of High Voltage Switchgear. GB/T 17626: Electro-magnetic Compatibility – Testing and M...
  • OEM Best partial discharge testing of cables Manufacturers –  GDPD-414H Handheld Partial Discharge Detector – HV Hipot

    OEM Best partial discharge testing of cables Manufacturers – GDPD-414H Handheld Partial Discharge Detector – HV Hipot

    Pictures for reference only. The GDPD-414H handheld Partial Discharge Detector adopts smart quick intelligent power test system (Soft No. 1010215, trademark registration number 14684481). It can flexibly configure various sensors according to different products to be tested. TEV, ultrasonic and HFCT are suitable for partial discharge detection of high-voltage switchgear and ring network cabinet; Ultrasonic and UHF are suitable for detecting GIS; Ultrasonic and HFCT are suitable for testing power cable. The built-in expert diagnosis system can analyze the test data and judge the discharge energy and possible parts. It is widely used in electric power and railway. Features ● Portable ABS engineering chassis. All PD detection hosts, tablets, sensors, chargers and signal cables are placed...
  • OEM Best to test earth resistance Suppliers –  Online Monitoring System of Circulating Current on Cable Sheath GDCO-301 – HV Hipot

    OEM Best to test earth resistance Suppliers – Online Monitoring System of Circulating Current on Cable Sheath GDCO-301 – HV Hipot

    General Information Cables above 35kV are mainly single-core cables with metal sheath. Since the metal sheath of the single-core cable is hinged with the magnetic field line generated by the AC current in the core wire, the two ends of the single-core cable have a high induced voltage. Therefore, appropriate grounding measures should be taken to keep the induced voltage within the safe voltage range (usually no more than 50V, but no more than 100V with safety measures). Usually, the metal sheath of short line single-core cable is grounded directly at one end and grounded through gap or protection resistor at the other end. The metal sheath of long line single – core cable is grounded by three – phase segmental cross – connection. No matter which kind of grounding me...