OEM Best Ct Pt Analyser Suppliers – GDHG-106B CT/PT Analyzer – HV Hipot
Features ● Finish all testing items by itself, no need to connect auxiliary equipment. ● Intelligent controller is adopted. ● Built-in printer, to print results easily. ● Large screen LCD, graphically display. ● Auto display excitation knee point value, 5% and 10% error curve. ● Save 3000 groups data and it is not lost after power down. ● With USB port. The data can be saved in USB disk and read by PC (WORD format file). ● Portable design, suitable for on-site test. ● Engineering plastic box with damping, strong and reliable. Specifications Main functions CT (protection type, metering type) PT Voltage current characteristic curve (excitation characteristic) Voltage current characteristic curve (excitation characteristic) Auto calculate knee point value Auto calculate knee p... -
OEM Best Infrared Gas Detector Factory – GDFJ-311M SF6 Gas Decomposition Product Tester – HV Hipot
General Information GDFJ-311M SF6 Gas Decomposition Product Tester is a portable device designed to measure SF6 gas decomposition product. The core component with electrochemical sensor from Membrapor to test SF6 gas decomposition product. Besides, we also adopt professional hardware chips and excellent software algorithms of STMicroelectronics. Application Decomposition product analysis of SF6 gas insulated electrical equipment Quality detection of recycled SF6 gas R&D use Reference standard DL/T 639-1997: Safety and Protection Guide for Operation Test and Maintenance Personnel of SF6 Electrical Equipment. Guodian No.72 Annex 3[1999] Measures for Quality Supervision and Management of High Voltage Switchgear. GB/T 17626: Electro-magnetic Compatibility – Testing and M... -
OEM Best Resistance Of Earth Continuity Conductor Manufacturers – GDKC-15 Series Circuit Breaker Analyzer 2020.12 – HV Hipot
General Information High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-15 Series is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy. GDKC-15 Series GDKC-15A GDKC-15B GDKC-15C GDKC-15D GDKC-15E GDKC-15F GDKC-15G GDKC-15H Metal contact 12 12 12 12 12 12 12 12 Closing resistance 6 6 6 6 6 6 6 Graphite contact 3 3 3 3 6 Double-ended grounding 3 3 3 6 Dynamic resistance(Pre-insertion resistor) 1 1 3 3 3 3 6 Static resistance 1 1 3 3 3 3 6 Ground resistance 3 6 Features ● It is suitable for the mechanical test of all types of SF6 switches, GIS combination appliances, vacuum switches and oil switches. ● Strong an... -
China High Quality Underground Pipe Detector Factories – GD-2134A Cable Identifier – HV Hipot
The purpose of the cable identifier is to accurately identify one of the target cables from multiple cables and avoid serious accidents caused by wrong sawing of live cables. Cable identification starts from the operation of both ends of the cable, it must be ensured that the double number on both ends of the cable is accurate. GD-2134A Cable Identifier is only suitable for on-site identification of de-energized cables. It is strictly forbidden to connect the cable identifier to the running power cable! Features ● Handheld receiver automatically identify and display the results to ensure that the results of cable identification are 100% accurate. Light weight and powerful, easy to carry. ● Suitable for on-site identification of de-energized cables. ● Both transmitter and handheld re... -
China High Quality Capacitor 1 Manufacturer – Insulation Materials Hipot Test Set GDJS-65 – HV Hipot
GDJS-65 Insulation Gloves Test Set It is used to test insulation performance for insulation gloves, boots, mats, hats, rod, Electroscope etc. It can test 6pcs insulation gloves/boots at the same time, also 5pcs insulation rods. Features Manual control unit ● Digital and real time display HV voltage, LV current, 6-way leak current and time. ● With leak current meter and over-current protection meter. ● With movable control unit, easy wiring and testing. ● Manual control, safety and reliability. ● With zero, power, operation, timing indicators. ● With over-current protection, zero-start protection, sound and light alarm, power protected switch. ● New type timer, broader timing range.(1s-99h). Other features ● HV source is oil immersed type testing transformer.(dry type and SF6 gas t... -
OEM Best Capacitor Testing Meter Price Manufacturer – PD free Variable Frequency Test System – HV Hipot
GDYT-350kVA/70kV PD free Resonant Test System is composed of PD free variable frequency power supply, HV measuring box, excitation transformer, isolation transformer, Resonant reactor, and capacitive voltage divider. This test system does not have the problem of excessive starting current. Using a smaller capacity power supply can complete a test equivalent to 30 to 60 times of the power supply, which greatly alleviates the problem of insufficient capacity of the field test power supply. Features ● Safety and reliable. It has many functions, including discharge and breakdown protection, over-voltage and over-current setting protection, test power off protection, zero protection, over-heat protection etc. When any protection happened, the system will immediately cut off output and po... -
OEM Best high voltage test equipment Manufacturer – Partial Discharge Online Monitoring System of Generators – HV Hipot
General Information Generally, partial discharge occurs at a position where the properties of the dielectric material are not uniform. At these locations, the local electric field strength is enhanced, and local electric field strength is too large, resulting in local breakdown. This partial breakdown is not the total breakdown of the insulating structure. Partial discharges typically require a certain amount of gas space to develop, such as gas voids inside the insulation, adjacent conductors, or insulating interfaces. When the local field strength exceeds the dielectric strength of the insulating material, a partial discharge occurs, causing many partial discharge pulses to occur during one cycle of applying the voltage. The amount of discharge delivered is closely related to the n... -
China High Quality Lightning protection tester Manufacturers – GDUD-PTM Ultrasonic Flaw Detector for Electrical Power Tower – HV Hipot
Features ● TFT true color screen. ● Using leading embedded digital system technology, the electrical performance indicators of the instruments are designed and manufactured according to the standard EN 12668.1 – 2000. ● Advanced and safe lithium polymer battery and power management technology, automatic alarm and protection. The automatic standby screen saver can be set to make the equipment more energy-efficient and longer-lasting, and to ensure continuous and efficient flaw detection. ● Application software that integrates intelligent and powerful processing functions, direct-reading user interface and operation mode, or digital knob one-button operation mode. ● Large-capacity detection parameters preset channel, convenient for users to operate on different detection objects... -
China High Quality soil resistivity testing methods Suppliers – GDHX-9700 Phase Detector – HV Hipot
General Information GDHX-9700 Phase Detector is mainly used in electric power lines, phase, and phase sequence calibration in substation, with main functions including electrical inspection, phase calibration and phase sequence measurement. It uses double shielding and brand-new digital circuits, with strong anti-interference, accorded with EMC standards, suitable for various electromagnetic interference situations. The high voltage phase signal of measured lead will be transmitted directly after treatment, the handset will receive and make phase comparison, determine the results after phase detection, real-time display phase angle difference and vector. It uses wireless transmission technology, safe and reliable, fast, and accurate, suitable for using at different voltage levels (10... -
China High Quality how to do dewpoint test Exporters – GDSZ-402 Automatic Acid Value Tester – HV Hipot
General Information Automatic Acid Value Tester is designed for testing acid value for transformer oil, turbine oil and fire resistant oil etc. PC control system can improve the work efficiency and reduce the harm in organic solvents and chemicals to human body. This instrument is easy to operate and have good capacity in anti-interference and stability. Features ● 320*240 LCD touch screen, user-friendly interface. ● Neutralization titration principle, to complete liquid charge, titrate, stir, determine the titration end point automatically under normal temperature. LCD screen can show the test result and print. ● Color sensor can match up the test titration end point, the judgment of end condition is reliable. ● Waste liquor cup is no need. ● Peristaltic pump control the cha... -
OEM Best Cable Tracker Manufacturer – GD-4136H Cable Fault Locating System – HV Hipot
GD4136H Cable Fault system is an important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1.GD-2131H Impulse Generator 2.GD-4132 Cable Fault Locator 3.GD-4133 Multi-pulse Cable Fault Detector 4.GD-4133S Multi-pulse Coupler 5.Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-4133 Cable Fault Tester, there are two locating ways: a. Low vol... -
China High Quality Ct Analyzer Exporters – GDHG-106B CT/PT Analyzer – HV Hipot
Features ● Finish all testing items by itself, no need to connect auxiliary equipment. ● Intelligent controller is adopted. ● Built-in printer, to print results easily. ● Large screen LCD, graphically display. ● Auto display excitation knee point value, 5% and 10% error curve. ● Save 3000 groups data and it is not lost after power down. ● With USB port. The data can be saved in USB disk and read by PC (WORD format file). ● Portable design, suitable for on-site test. ● Engineering plastic box with damping, strong and reliable. Specifications Main functions CT (protection type, metering type) PT Voltage current characteristic curve (excitation characteristic) Voltage current characteristic curve (excitation characteristic) Auto calculate knee point value Auto calculate knee p...