Featured

  • China High Quality Wire Tracers Electrical Factory –  GDCF-900T Vehicle Mounted Cable Fault Locating System – HV Hipot

    China High Quality Wire Tracers Electrical Factory – GDCF-900T Vehicle Mounted Cable Fault Locating System – HV Hipot

    Vehicle Mounted Cable Fault Locator system is used for Cable Fault conditioning (burn-down), Pre-Location, Route Location, Pin-pointing & Testing of HV & LV cables of different types&sizes. The set is suitable to carrying out the above-mentioned multifunction on power cables of various voltage levels mainly 33KV, 11KV, 415V and control cables with 1.1 KV grade. The set shall be used for cable types namely XLPE, PVC, PILC with Al / Cu conductor. The cables are laid underground (under plain earth, trenches, or RCC surface, Horizontal Drilling in HDD Pipe), above ground or partly under & partly above ground with maximum cable length around 25Km. The cable fault locator is suitable for fault locating and pinpointing the following types of cable faults. ● High resistance ● L...
  • OEM Best Square Wave Generator Suppliers –  GDB-H Handheld Automatic Transformer Turns Ratio Tester – HV Hipot

    OEM Best Square Wave Generator Suppliers – GDB-H Handheld Automatic Transformer Turns Ratio Tester – HV Hipot

    General Information GDB-H is a hand-held device. It can accurately measure turns ratio, group and phase angle, which is suitable for all kinds of transformers such as Z type transformers, rectifier transformers, electric furnace transformers, phase-shifting transformers, traction transformers, scott and invert-scott transformers. Function Features ● 5.6inch TFT color LCD screen, intuitively display data and vector diagram. ● 3-phase testing at the same time. Single phase power input, with internal digital combination standard sine wave test source. It generates 3-phase test power (degree of distortion is less than 0.1%, degree of symmetry is better than 0.05%) by Hi-fi power amplifier. The test results have a better equivalence, and it won’t appear constituencies misjudgmen...
  • China High Quality Primary Injection Tester Ac Supplier –  GDHL-200B / GDHL-500B / GDHL-600B Contact Resistance Tester (Microhm meter) – HV Hipot

    China High Quality Primary Injection Tester Ac Supplier – GDHL-200B / GDHL-500B / GDHL-600B Contact Resistance Tester (Microhm meter) – HV Hipot

    Features ● Output high-current continuously. ● Quick and accurate test. Test current is generated from high-precision 100A/200A switching mode constant current power supply, no need for manual adjustment. ● Adopts four-terminal wiring method. The influence of test line resistance on test results is effectively eliminated. ● Stable performance. There is over-heat protection crcuit designed for long-time working. ● Light weight, easy to carry and operate. Specifications GDHL-500B Contact Resistance Tester (Micro-ohm Meter) Specifications Accessories Main unit   1 set  Test wire 4 pieces Power cord 1 piece Print paper 2 rolls Ground cable 1 piece User’s guide 1 copy Test Report 1 copy GDHL-600B Contact Resistance Tester (Micro-oh...
  • China High Quality Test power meter Factories –  GDPQ-300A Handheld Power Quality Analyzer – HV Hipot

    China High Quality Test power meter Factories – GDPQ-300A Handheld Power Quality Analyzer – HV Hipot

    Features ● The instrument is a high-precision test instrument specially used to detect power quality problems such as waveform distortion, harmonic content and three-phase unbalance in the power grid. It also has the functions of electrical parameter test and vector analysis. ● Can accurately measure voltage, current, active power, reactive power, phase angle, power factor, frequency and other electrical parameters. ● It can display the vector diagram of the measured voltage and current. The user can analyze the vector diagram to get the correctness of the wiring of the metering equipment. ● The current is measured by a clamp-type transformer. Operator does not need to disconnect the current loop when measuring with a clamp-type current transformer, the measurement can be convenientl...
  • China High Quality power distribution transformer Factory –  GDJF-2007 Digital Partial Discharge Analyzer – HV Hipot

    China High Quality power distribution transformer Factory – GDJF-2007 Digital Partial Discharge Analyzer – HV Hipot

    Picture only for reference first. GDJF-2007 Digital Partial Discharge Analyzer is widely used for detecting partial discharge of high voltage equipment such as power transformers, instrument transformer, HV circuit breaker, GIS, Zinc oxide surge arrester, power cable. It also can make type tests and monitor insulation operation. It includes main unit, PD software, current transformer, input unit, calibration pulse generator, input adapter, antenna amplifier and connection cable etc. Features ● 12inch LCD display, with portable design, rugged and durable, easy to use. ● Strong anti-interference ability, accurate. Using digital filtering technology, field interference can be effectively eliminated, and partial discharge measurement can be realized in a strong interference environmen...
  • OEM Best Undergorund Cable Detector Factory –  GD-2134A Cable Identifier – HV Hipot

    OEM Best Undergorund Cable Detector Factory – GD-2134A Cable Identifier – HV Hipot

    The purpose of the cable identifier is to accurately identify one of the target cables from multiple cables and avoid serious accidents caused by wrong sawing of live cables. Cable identification starts from the operation of both ends of the cable, it must be ensured that the double number on both ends of the cable is accurate. GD-2134A Cable Identifier is only suitable for on-site identification of de-energized cables. It is strictly forbidden to connect the cable identifier to the running power cable! Features ● Handheld receiver automatically identify and display the results to ensure that the results of cable identification are 100% accurate. Light weight and powerful, easy to carry. ● Suitable for on-site identification of de-energized cables. ● Both transmitter and handheld re...
  • China High Quality Cable Fault Location System Factory –  GD-7018A Optical Fiber Identifier – HV Hipot

    China High Quality Cable Fault Location System Factory – GD-7018A Optical Fiber Identifier – HV Hipot

    The GD-7018 series optical fiber pipeline identifier can accurately locate and meaure depth of the underground pipelines, cables and optical cables under the condition of without digging, and accurately find the damage points of the outer coating of the underground pipelines and the location of the underground cable fault points. The instrument incorporates the most advanced technologies such as ultra-narrow band filter, Bluetooth wireless communication, GPS positioning, automatic data mapping by professional data analysis software and automatic generation of test reports. The detection and inspection of various kinds of metal pipelines, pipeline management and maintenance, municipal planning and construction, pipeline inspection in power supply and other departments is one of the neces...
  • OEM Best Voltage Coupling Manufacturers –  AC Dielectric Test Equipment with manual control unit GDYD-D – HV Hipot

    OEM Best Voltage Coupling Manufacturers – AC Dielectric Test Equipment with manual control unit GDYD-D – HV Hipot

    Application Features ● Digital (Pointe) display panel mounted controls & indicators with easy-to-read legend. ● Monitoring high voltage side voltage, low voltage side current and indicator of zero, power, working start, timing. ● Over-current protection, zero-starting protection, sound, and light alarm. ● Continuously variable output from zero to full voltage. ● Adjustable over current protection, with trip levels variable from 10 to 110%. ● With new type time relay, time range is wider (1S ~ 99H). ● Using the latest current relay, more accurate and reliable. ● Light weight, small size, easy to move. Technical Specifications ● Input voltage: AC 220V or 380V ● Output voltage of control unit: AC 0-250V or 0-430V ● Output current of control unit:0-5/10/15/50A(customized) ● Ca...
  • China High Quality Wire Tester Suppliers –  GD-2134A Cable Identifier – HV Hipot

    China High Quality Wire Tester Suppliers – GD-2134A Cable Identifier – HV Hipot

    The purpose of the cable identifier is to accurately identify one of the target cables from multiple cables and avoid serious accidents caused by wrong sawing of live cables. Cable identification starts from the operation of both ends of the cable, it must be ensured that the double number on both ends of the cable is accurate. GD-2134A Cable Identifier is only suitable for on-site identification of de-energized cables. It is strictly forbidden to connect the cable identifier to the running power cable! Features ● Handheld receiver automatically identify and display the results to ensure that the results of cable identification are 100% accurate. Light weight and powerful, easy to carry. ● Suitable for on-site identification of de-energized cables. ● Both transmitter and handheld re...
  • China High Quality Relay Protection Tester Supplier –  GDJB-6000M Smart Substation Relay Protection Test System – HV Hipot

    China High Quality Relay Protection Tester Supplier – GDJB-6000M Smart Substation Relay Protection Test System – HV Hipot

    GDJB-6000M Smart Substation Relay Protection Test System is a new generation of intelligent relay protection tester designed according to “Smart Substation Relay Protection Technical Specifications” and “Smart Substation Technical Guidelines”. It can not only realize the full function test of the optical digital protection device (IEC61850, smart digital station), but also carry out full function test on the traditional protection device (conventional station). GDJB-6000M is a portable new product independently developed through the use of technologies such as embedded real-time operating systems, high-performance embedded processors, and large-scale logic devices, combined with power field conditions and numerous power user experiences. It is widely applicable t...
  • China High Quality leakage current tester Manufacturer –  GDUD-PTM Ultrasonic Flaw Detector for Electrical Power Tower – HV Hipot

    China High Quality leakage current tester Manufacturer – GDUD-PTM Ultrasonic Flaw Detector for Electrical Power Tower – HV Hipot

    Features ● TFT true color screen. ● Using leading embedded digital system technology, the electrical performance indicators of the instruments are designed and manufactured according to the standard EN 12668.1 – 2000. ● Advanced and safe lithium polymer battery and power management technology, automatic alarm and protection. The automatic standby screen saver can be set to make the equipment more energy-efficient and longer-lasting, and to ensure continuous and efficient flaw detection. ● Application software that integrates intelligent and powerful processing functions, direct-reading user interface and operation mode, or digital knob one-button operation mode. ● Large-capacity detection parameters preset channel, convenient for users to operate on different detection objects...
  • OEM Best Capacitance Setting On Multimeter Manufacturer –  GDZJ-30S Turn-to-Turn Surge Withstand Tester – HV Hipot

    OEM Best Capacitance Setting On Multimeter Manufacturer – GDZJ-30S Turn-to-Turn Surge Withstand Tester – HV Hipot

    General Information Specifications Input voltage 220V±5%; frequency 50/60Hz±2% Measurement range 0-30kV, continuous adjustment, ±5% Trigger times 6.25 time/s - 50 times/s Waveform rising time 0.1-0.5μS Capacitance error (+0.3) / (-0.1) µs Impulse capacitance 0.01μF -0.1μF Max output energy 60J Power consumption 1000VA Insulation resistance Insulation resistance between power input terminal and tester ≥20MΩ Dielectric strength 1500V/50Hz at 1min, there is no flashing and breakdown for withstand voltage test. Temperature 0-40 degree Relative humidity ≤80% at 40 degree Waveform capacitance deviation ±3% Dimension 650*550*1700mm Weight 100kg Application Turn to turn withstand voltage test ...

Send your message to us:

Write your message here and send it to us