China High Quality Ct/Pt Tester Factories – GDHG-106B CT/PT Analyzer – HV Hipot
Features ● Finish all testing items by itself, no need to connect auxiliary equipment. ● Intelligent controller is adopted. ● Built-in printer, to print results easily. ● Large screen LCD, graphically display. ● Auto display excitation knee point value, 5% and 10% error curve. ● Save 3000 groups data and it is not lost after power down. ● With USB port. The data can be saved in USB disk and read by PC (WORD format file). ● Portable design, suitable for on-site test. ● Engineering plastic box with damping, strong and reliable. Specifications Main functions CT (protection type, metering type) PT Voltage current characteristic curve (excitation characteristic) Voltage current characteristic curve (excitation characteristic) Auto calculate knee point value Auto calculate knee p... -
China High Quality megger sales Supplier – GDCR3000 Digital Earth Resistance Tester – HV Hipot
General Information GDCR3000 Digital Earth Resistance Tester is specially designed and manufactured for field measurement, adopting the latest digital and micro-processing technology, 3-pole or 2-pole method for earth resistance measurement, with a unique function of wire resistance verification, anti-interference capability and the ability to adapt to the environment, to ensure high precision, high stability and reliability for prolonged measure, which is widely used in electric power, telecommunications, meteorology, oil field, construction, lightning protection, industrial electrical equipment and other earth ground resistance measurement. Measurement range & Accuracy Measurement function Range Accuracy Resolution Earth resistance 0.01Ω~20Ω ±2%rdg ±3dgt (Auxiliary ear... -
China High Quality distribution transformer testing Manufacturers – GDJF-2006 Partial Discharge Analyzer – HV Hipot
Features ● With high speed, big capacity data acquisition card. Continuously collect partial discharge data, good repeatability, and high accuracy. ● Functions of testing, analyzing (multi-parameter analysis, two-dimension atlas analysis, three-dimension atlas analysis), data storage, report, and print. Display waveform (ellipse, sine wave, line), discharge value and test voltage. ● Suitable for 50Hz, 150Hz frequency power supply, up to 400Hz. Automatic tracking external power supply frequency. ● Big color LCD screen. Large memory, with USB port. ● With anti-false operation function. Automatic adjusting gain during testing and rectifying. ● Anti-interference design. Specifications ● Capacitance range: 6pF-250μF ● Sensitivity: <0.02pc (capacitance at 50pF) ● Am... -
OEM Best Cable Locator Calibration Factories – GD-4138H Cable Fault Locating System – HV Hipot
GD-4138H Mobile Cable Fault Locating System is important tool to maintain all kinds of cables. It is compatible equipment that can trace, locate the underground cables, with fault distance measurement and HV generation. As it is movable device, it is convenient to carry on-site. If acoustic locator is used together, it can locate accurate position of cable fault point. Application is underground cable, aerial cable, power cable, local cable, communication cable and fiber cable. Typical fault to be detected includes ● High impedance flash-over fault ● High impedance leak ● High/low resistive grounding ● Short-circuit fault ● Open-circuit fault ● Poor connection/Disconnection GD-4138L system includes ● GD-4138H main frame (Coupling device, Sphere gap, HV generator are inside) ● GD-... -
OEM Best megger products Supplier – GDHX-9500 Phase Detector – HV Hipot
General Information GDHX-9500 Phase Detector is mainly used in electric power lines, phase and phase sequence calibration in substation, with main functions including electrical inspection, phase calibration and phase sequence measurement. It uses double shielding and brand new digital circuits, with strong anti-interference, accorded with EMC standards, suitable for various electromagnetic interference situations. The high voltage phase signal of measured lead will be transmitted directly after treatment, the handset will receive and make phase comparison, determine the results after phase detection, real-time display phase angle difference and vector.It uses wireless transmission technology, safe and reliable, fast and accurate, suitable for using at different voltage levels (6V-50... -
OEM Best Cable Fault Locator Suppliers – GD-2134E Cable Identifier – HV Hipot
GD-2134E is a high-performance underground metal pipeline detection system composed of signal transmitters and receivers. It can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables. It can carry out uniqueness identification with a variety of selected accessories, as well as pipe insulation damage and the search for some types of cable faults. Features ● Compass display: intuitively displays the pipeline location and left & right directions. ● Tracking true and false prompts: current direction measurement, tracking correct error prompts, eliminating line interference (some frequencies). ● Depth and current measurements, can display the signal strength historical curve. ● Fully digital high-precision sampling processing: sta... -
China High Quality A Bridge Used For The Measurement Of Capacitance Is Manufacturers – 30kVA.200kV Automatic AC.DC Hipot Test Set GDYD-2030A – HV Hipot
Features ● 7inch color LCD screen, with PLC automation control. ● HV Voltage, LV voltage, LC current measured at the same time, with high precision sensor and high-performance collection chip. ● Automatic mode and manual mode for option. ● Display HV voltage, LV voltage, LV current, time, and withstanding result. ● Over-voltage and over-current protection. Output voltage, HV current upper limit, LV current upper limit and timing can be set. ● Zero-starting function. Test can be proceeded after the voltage is back to zero. ● Store up to 8000pcs data in 3months. It has USB port to upload data to USB disk. ● When setting voltage is arrived, it will be timing automatically. After timing, voltage will be back to zero. ● When the LV current is over setting value, the voltage will be cut of... -
China High Quality relay testing Manufacturers – GDJR-200D Single Phase Electronic Thermal Relay Calibrator – HV Hipot
Standard compliance GB/T 14598.15-1998 Electric Relays Part 8: Thermal Electrical Relays DL/T 624-1997 Technical Specification of Test Equipment Based on Micro-computer for Relaying Protection DL/T 846-2004 General Technical Specifications for High Voltage Test Equipments DL/T 596-2005 Preventive Test Code for Electric Power Equipment GB50150-2006 Electrical Equipment Installation Engineering-standard for Hand-over Test of Electric Equipment GB1094.1-GB1094.6-96 Degrees of Protection Provided by Enclosure (IP Code) GB2900 Electro-technical terminology GB/T16927.1~2-1997 High Voltage Test Techniques GB4793-1984 Safety Requirements for Electronic Measuring Apparatus GB191 Packaging-Pictorial Marking for Handling of Goods GB/T.311-1997 Insulation co-ordination for... -
OEM Best Purity Test Manufacturer – GD8000C SF6 Gas Leak Online Monitoring System – HV Hipot
Product Description GD8000C quantitatively leak online monitoring system is mainly used in the 35KV SF6 switch room and 500KV, 220KV, 110KV GIS room in the substation to monitor the SF6 gas leakage in the SF6 combined electrical equipment room environment and the oxygen content in the air in real time. When SF6 gas leaks, the density of SF6 gas is more than 5 times that of air, which accumulates in the lower space and causes local oxygen deficiency, that may cause major accidents. The system uses multiple sets of new high-sensitivity imported SF6-O2 sensors and temperature and humidity sensors. When the indoor SF6 and O2 concentrations change slightly, the sensors can respond to these changes immediately, even if the SF6 concentration is 10ppmv can be effectively monitored. The conce... -
China High Quality relay test secondary kit Exporters – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot
Features A. Working conditions 1. Power supply: AC 220V±10%,50Hz 2. Working environment: Temperature -10℃~40℃; Humidity: ≤85% 3. Atmosphere: 86-106kPa B. Output power supply 1. AC voltage: 0-220V/3A Adjustable 2. AC current: 0-100A/7V (200A can be customized); 0-20A/25V Adjustable; 0-5A/5V Adjustable 3. DC voltage: 0-220V/3A Adjustable 4. DC current:0-20A/25V 5. Fixed voltage output: DC 24V/48V/110V/220V 6. Current/Voltage accuracy: ±1%. C. Performance Index 1. Ammeter and voltmeter: 41/2 digit. 2. Digital millisecond meter: 0-99.9999s(999.999s can be customized) Resolution: 0.1ms. D. Functions 1. Measure relay: Measure start value, return value and drop-off to pick-up ratio of current, voltage relay. 2. Time relay: Measure start value, return value and action time. 3. Intermed... -
China High Quality Pt Test Manufacturers – GDHG-108A CT/PT Tester – HV Hipot
GDHG-108A CT/PT Tester supports test voltage method to test bushings CTs which installed on transformer or inside switch-gear, suitable for the laboratory and on-site detection. Itcan be easily and conveniently done voltage current characteristic, transformer ratio, ratio and phase angle error, load test items on CT/PT. Features ● Using the voltage detection principle to measure CT and PT. ● To meet the requirements of GB1207, GB1208, GB168-47 (IEC60044-1.6) and other standards. ● No external auxiliary equipment, a single machine can complete all test items. ● With high speed micro printer: real-time print the test result. ● Using intelligent controller, operation is simple. ● 5inch LCD screen display. ● Automatically given CT/PT (excitation) knee point value. ● Auto display 5% and 1... -
China High Quality overcurrent relay testing Manufacturer – GDJB-6000M Smart Substation Relay Protection Test System – HV Hipot
GDJB-6000M Smart Substation Relay Protection Test System is a new generation of intelligent relay protection tester designed according to “Smart Substation Relay Protection Technical Specifications” and “Smart Substation Technical Guidelines”. It can not only realize the full function test of the optical digital protection device (IEC61850, smart digital station), but also carry out full function test on the traditional protection device (conventional station). GDJB-6000M is a portable new product independently developed through the use of technologies such as embedded real-time operating systems, high-performance embedded processors, and large-scale logic devices, combined with power field conditions and numerous power user experiences. It is widely applicable t...