  • China High Quality Underground Cable Locating Suppliers –  GD-2134E  Cable Identifier – HV Hipot

    China High Quality Underground Cable Locating Suppliers – GD-2134E Cable Identifier – HV Hipot

    GD-2134E is a high-performance underground metal pipeline detection system composed of signal transmitters and receivers. It can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables. It can carry out uniqueness identification with a variety of selected accessories, as well as pipe insulation damage and the search for some types of cable faults. Features ● Compass display: intuitively displays the pipeline location and left & right directions. ● Tracking true and false prompts: current direction measurement, tracking correct error prompts, eliminating line interference (some frequencies). ● Depth and current measurements, can display the signal strength historical curve. ● Fully digital high-precision sampling processing: sta...
  • OEM Best soil resistivity measure Manufacturers –  Dielectric Loss Tester for Live Capacitive Equipment GDDJ-HVC  – HV Hipot

    OEM Best soil resistivity measure Manufacturers – Dielectric Loss Tester for Live Capacitive Equipment GDDJ-HVC – HV Hipot

    General Information There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. If the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be found in ...
  • China High Quality dew point gauge Manufacturers –  GDC-9560B Power System Insulation Oil Gas Chromatograph Analyzer – HV Hipot

    China High Quality dew point gauge Manufacturers – GDC-9560B Power System Insulation Oil Gas Chromatograph Analyzer – HV Hipot

    General Information  GDC-9560B Gas Chromatograph Analyzer is to analyze the gas content of insulation oil by gas chromatographic method. It is effective to judge if the running equipment has potential fault like over-heat, discharge or not, to ensure the safety of power grid. It is also necessary to be used for manufacturer of gas/oil equipment to inspect their equipment before leaving factory. Gas chromatography analysis technology is a technique for separation and analysis of multi-component mixtures. It mainly uses the difference of boiling point, polarity and adsorption coefficient of each component in the sample in the column, so that the components are separated in the column, and the separated components are qualitatively and quantitatively analyzed. The gas chromatograph uses...
  • China High Quality Voltage Ac Suppliers –  VLF AC Hipot Test Set 80kV – HV Hipot

    China High Quality Voltage Ac Suppliers – VLF AC Hipot Test Set 80kV – HV Hipot

    Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. AC test can be further divided into power frequency, variable frequency and 0.1Hz very low frequency test, among which the last one is highly recommended by IEC, due to its remarkable advantages. Following is a comparison for DC, Power Frequency, Variable Frequency, and 0.1Hz test. Aspects DC Power Frequency Variable Frequency 0.1Hz Equivalency poor good good good Insulation Damage strong slight slight slight Operation Safety relatively low relatively low relatively low high Wiring Difficulty complicated complicated most complicated simple Volume smallest largest large smal...
  • China High Quality Dc Test Breaker Supplier –  GDGK-501 DC Power Supply – HV Hipot

    China High Quality Dc Test Breaker Supplier – GDGK-501 DC Power Supply – HV Hipot

    Features ● Using contact regulators to output voltage and rectify by rectifier bridge. ● The output voltage is continuous adjusted. ● Thermal cut-outs for short-circuit protectors at DC output. ● Small size, light weight. Specifications ● Input Voltage: AC220V±10%, 50Hz, single phase ● Capacity: 3kVA ● Output Voltage: AC 0-260V DC 0-360V ripple: 3% ● Output Current: 10A (continuous), 20A(short time) ● 24vdc, 48vdc, 110vdc, and 250vdc, 15A ● Maximum load current: 20A ● Accuracy: 1.5% of the range ● Temperature: -10℃-45℃, humidity: <80% ● Dimension: 440*340*240 mm ● Weight: 18kg Accessories Test Box 1 set Power cord 1 piece Ground wire 1 piece Test wire 6 pieces Manual 1 piece Factory test report 1 copy Packing list 1 copy
  • OEM Best Electrical Pd Suppliers –  Partial Discharge Online Monitoring System of GIS – HV Hipot

    OEM Best Electrical Pd Suppliers – Partial Discharge Online Monitoring System of GIS – HV Hipot

    General Information Gas-insulated metal-enclosed switches (GIS) and gas-insulated metal-enclosed transmission lines (GIL) are one of the most important devices in the power system. They have the dual tasks of control and protection. If they failed during operation and the problem cannot be solved timely,it will cause serious damage to the grid. Partial discharge fault is a common fault type of GIL/GIS. It is necessary to use GIS partial discharge online monitoring and fault location system to perform real-time online monitoring of GIL/GIS partial discharge signals and analyze and process the measured data and real time give comprehensive judgment of insulation status. Then repair schedule can be arranged according to the monitoring results to avoid major grid accidents caused by equi...
  • China High Quality ipec partial discharge Manufacturer –  GDJF-2008 Partial Discharge Analyzer – HV Hipot

    China High Quality ipec partial discharge Manufacturer – GDJF-2008 Partial Discharge Analyzer – HV Hipot

    GDJF-2008 Partial Discharge Detector is measuring partial discharge for the products such as transformers, mutual inductors, HV switches, zinc monoxide arresters and power cables. It also can make type tests and monitor insulation operation. This type has the advantages of high sensitivity, wide range of capacitance, being well equipped for input unit impedance detecting and more variants of frequency bands (9 in all). After proper setting, the discharge impulse amount can be read directly. The indicating and digital meters are shown simultaneously. This detector is widely applied in power stations, manufacturers, and institutions. Use Condition ● Ambient temperature: 0-40℃±2℃. ● Relative humidity: ≤80% ● Power supply: 220V±10%, 50HZ. ● No violent vibration and mechanical shock. ● Th...
  • OEM Best battery tester with printer Suppliers –  Onsite AC power supply – HV Hipot

    OEM Best battery tester with printer Suppliers – Onsite AC power supply – HV Hipot

    General information The GDUP-1000 is a versatile portable pure sine wave on-site AC test power supply. Also known as on-site AC and DC test power supply, AC and DC emergency power supply, field test power supply, mobile test power supply. It has a safe power lithium-ion battery and efficient SPWM inverter conversion technology, with light weight, small size, long life and high capacity. Application Widely used in outdoor equipment such as power equipment emergency repair, power field test, mobile office, medical rescue, fire emergency rescue, environmental protection, emergency communication support, and power storage backup. It also provides a safe and reliable power source for instruments in the laboratory or in the field.  Main Application 1. 220V/50Hz pure sine wave AC outp...
  • China High Quality single phase relay test unit Factory –  GDJB-6000M Smart Substation Relay Protection Test System – HV Hipot

    China High Quality single phase relay test unit Factory – GDJB-6000M Smart Substation Relay Protection Test System – HV Hipot

    GDJB-6000M Smart Substation Relay Protection Test System is a new generation of intelligent relay protection tester designed according to “Smart Substation Relay Protection Technical Specifications” and “Smart Substation Technical Guidelines”. It can not only realize the full function test of the optical digital protection device (IEC61850, smart digital station), but also carry out full function test on the traditional protection device (conventional station). GDJB-6000M is a portable new product independently developed through the use of technologies such as embedded real-time operating systems, high-performance embedded processors, and large-scale logic devices, combined with power field conditions and numerous power user experiences. It is widely applicable t...
  • China High Quality Tan Delta Bridge And Capacitors Factory –  DC High Voltage Generator GDZG-300 – HV Hipot

    China High Quality Tan Delta Bridge And Capacitors Factory – DC High Voltage Generator GDZG-300 – HV Hipot

    Features ● Simple operation and complete function, easy for wild work. ● Higher voltage stability, smaller ripple coefficient. ● More reliable and stable, continuous short-circuit discharge directly to ground. ● Intelligent grounding protection and alarm function. High precision, accurate measurement, digital display of voltmeter and ammeter, with voltage resolution 0.1kV, and current 0.1uA. ● High stability of voltage regulation, smooth voltage boosting process, high adjustable precision, with coarse and fine adjustment functions. Accuracy of voltage regulation better than 0.1%, voltage and current measurement error is less than 1.0%, ripple factor better than 0.5%. ● With function of high-accuracy 75%VDC-1mA, more convenient for zinc oxide lighting arrester DC testing. ● HV booste...
  • China High Quality grid substation earthing Supplier –  Substation Temperature Monitoring System – HV Hipot

    China High Quality grid substation earthing Supplier – Substation Temperature Monitoring System – HV Hipot

    General Information There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. As long as the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be f...
  • China High Quality tensile machine Exporters –  Transformer Oil Gas Chromatography Online Monitoring System – HV Hipot

    China High Quality tensile machine Exporters – Transformer Oil Gas Chromatography Online Monitoring System – HV Hipot

    General Information  GDDJ-DGA Transformer Oil Gas Analyzer is an online monitoring device for dissolved gas in transformer oil based on gas chromatography technology. Potential fault are determined, release alert as per preset value through expert diagnosis system. The device adopts distributed control sampling technology and has self-diagnosis and self-recovery functions. Each function module is weak coupling, function independent, adopting rack structure, easy for engineering maintenance. Features ● Maintenance-free, no need to replace gas cylinder. ● On-line detection the concentration and growth rate of H2, CO, CO2, CH4, C2H4, C2H2, C2H6. ● Modular design and compact structure, easy for maintenance, with high expansibility, can be easily integrated to other monitoring equipmen...