OEM Best electrical earthing system Supplier – GD2000H 10kV Insulation Resistance Tester – HV Hipot
General Information This device can test insulation resistance (such as transformer, switchgear, leads, motor) of different modules in one system, to insulate and repair failure components. It is important to ensure products quality and security of person and equipment during operation by insulation test of checking test object to ground or adjacent conductors’ insulation. Before power on the system, use insulation test to verify if it is good to improve system performance. Insulation test is to find manufacturing process problems and equipment fault which can’t be found before failure happened. In EU, this test is compulsory, even to civil system. Features 1. Voltage output GD2000H (5kV/10kV).Resistance range 0-400GΩ. 2. Two modes display insulation resistance. 3. Aut... -
OEM Best Circuit Breaker Testing Factories – GDZK-IV Vacuum Degree Tester for Vacuum Breaker – HV Hipot
Features ● Measure vacuum degree in vacuum interrupter for every types of breakers. ● Electromagnetic measuring method, Accurate and Reliable. ● No need to dismantle the vacuum breaker in measurement. ● 128*64 pixel LCD screen, easy to operate. The test results are directly compared with the standard values to determine whether they are qualified;Save, print and check testing data. ● RS-232 port, connecting with PC to download vacuum degree-ionic current curve, to estimate lifespan. ● Light weight, Portable. Specifications ● Power Supply: AC220V ± 20%, 50Hz. ● Testing Range: 10-5 ~10-1Pa. ● Electric field Voltage: 20kV. ● Magnetic field Voltage: 1600V. ● Accuracy: 20%-25% at 10-5 ~10-4. 15%-20% at 10-4 ~10-3 10%-15% at 10-3 ~10-2 5%-10% at 10-2 ~10-1 ● Ambient Temperature: -1... -
China High Quality earthing meter Supplier – GDCR3200C Double Clamp Multifunctional Earth Resistance Tester – HV Hipot
General Information GDCR3200C Double Clamp Multifunctional Earth Resistance Tester is specially designed and manufactured for on-site measurement of grounding resistance, soil resistivity, grounding voltage, grounding line leakage current, AC current and DC resistance. The instrument adopts advanced digital processing technology, with 2-wire method, 3-wire method, 4-wire method, selection method, double clamp method and other measurement methods; Import FFT (Fast Fourier Transform) technology, AFC (Automatic Frequency Control) technology, with unique anti-interference ability and environmental adaptability, high repeated test consistency, ensuring high precision, high stability and high reliability for long-term measurement.The instrument used large caliber current clamp design, can ... -
OEM Best Air Circuit Breaker Testing Manufacturers – GDSL-A Seriese Automatic Primary Current Injection Test Set – HV Hipot
Features ● Built-in high configuration industrial control computer, the programmable logic controller (PLC) as the central processor, real-time scan of AC signal, to achieve comprehensive monitoring and closed-loop control, and design password settings management, only the personnel who gets corresponding operation authority, can carry out operation of certain functions. ● Color LCD touch screen. Using intelligent sensor based on field bus technology and realize the full digital data transmission, display operation unit is touch type color LCD screen, full English menu, the interface is clear and intuitive, the operation is simple and convenient. Test without any auxiliary equipment, automatic control, fast, simple and convenient. ● Automatic and manual test mode, with automatic cons... -
OEM Best flaw detector Manufacturer – GDUD-PBI Ultrasonic Flaw Detector for Electrical Equipment – HV Hipot
Applications It detects internal flaws of electrical equipment, such as bushings, bus bars, wire clamps, transformer tank, current&voltage transformers, surge arresters, generator bearing equipment, and porcelain pillar type insulators, etc. Features ● TFT true color screen. ● High accuracy and wide applications. ● High sensitivity of flaw detection, up to 110db. ● Built-in standard curves and test block for pillar type insulators. The device alarms if internal crackle flaws are super-standard. ● Automatic calibrations for probe and curvature surface, which optimizes the coupling between the probe and test object and ensures accuracy. ● Aluminum alloy chassis, which has excellent anti-interference performance. Low noise and high signal-to-noise ratio. Specifications ● Worki... -
OEM Best Low Resistance Tester Exporters – GDSL-BX-200 Primary Current Injection Test Set – HV Hipot
Features ● Digital control, high anti reference ability. ● Adapts autotransformer regulator which with low power consumption and large capacitance. ● Converter has high permeability core. ● Quick connects, lock design, have good current capability. ● PVC panel. ● Build-in quick plug with high safety. ● Current range can be changed, easy to read. ● Engineering plastics box, IP67 dustproof and waterproof. ● Portable design is suitable for on-site testing. ● Zero start function to prevent the test objects from damage caused by high current impulsing. The equipment only can be started at zero. ● Impulse choosing function: The current value can be outputted directly without zero protection function when the equipment is under the testing for circuit breaker. ● 0-50A AC current can be outp... -
OEM Best Gas Humidity Manufacturers – GDJD-3A SF6 gas Density Relay Calibrator – HV Hipot
Product Description GDJD-3A SF6 gas Density Relay Calibrator is automatic calibrator, which uses embedded microprocessor to proceed performance calibration for all kinds of SF6 gas density relay. It is also a portable device which can make standard conversion for SF6 gas pressure at any environmental temperature. This device is mainly used for SF6 gas products production, maintenance and monitoring in power system. Features ● Automatically calibrate density relay and pressure gauge. ● Compact design, small size, and light weight, easy to carry. ● Color LCD screen, Windows menu. ● The power supply has UPS function, suitable for field operation. ● With mini-printer, to print test result directly. ● Good sealing property, do not waste SF6 gas during calibration. ● The two ends of con... -
China High Quality Current Impulse Generator Suppliers – GDB-P Auto Transformer Turns Ratio Tester – HV Hipot
General Information According to IEC and the relevant national standards, transformer turns ratio test is a necessary project in the process of power transformer production, user handover and maintenance test. This way can effectively monitor the quality of transformer products in the factory and use process, prevent transformer turn to turn short circuit, open circuit, connection error, internal fault or contact fault of tap changer. GDB-P Transformer turns ratio tester has the characteristics of simple operation, complete function, stable and reliable data. So far, GDB-P is the first one in China can carry out blind measurement (enable to accurate measurement and measurement phase angle without knowing the connection mode and the group’s condition of the tested transformer); ... -
China High Quality Hipot Test Voltage Supplier – Partial Discharge Test System GDYT series – HV Hipot
GIT Series GIS High Voltage Test Sets integrate the high voltage boosting, high voltage measurement, high voltage transformer, high voltage coupling capacitors and all components in a sealed space. There are two modes to generate high voltage 1) Using reactor inductance and test object capacitance to realize voltage resonance test, to obtain a high voltage, high current from test object. 2) The other one is to obtain required high voltage directly from high voltage transformer. It is widely used for high voltage, big capacity GIS power equipment insulated withstand voltage test, partial discharge test and GIS transformer accuracy test, suitable for GIS substation, GIS power equipment manufacturer, basin type electrical insulator manufacturer. Features ● The High voltage o... -
OEM Best Vlf Hipot Test Set Manufacturers – GDZJ-30S Turn-to-Turn Surge Withstand Tester – HV Hipot
General Information Specifications Input voltage 220V±5%; frequency 50/60Hz±2% Measurement range 0-30kV, continuous adjustment, ±5% Trigger times 6.25 time/s - 50 times/s Waveform rising time 0.1-0.5μS Capacitance error (+0.3) / (-0.1) µs Impulse capacitance 0.01μF -0.1μF Max output energy 60J Power consumption 1000VA Insulation resistance Insulation resistance between power input terminal and tester ≥20MΩ Dielectric strength 1500V/50Hz at 1min, there is no flashing and breakdown for withstand voltage test. Temperature 0-40 degree Relative humidity ≤80% at 40 degree Waveform capacitance deviation ±3% Dimension 650*550*1700mm Weight 100kg Application Turn to turn withstand voltage test ... -
OEM Best earth electrode test Manufacturers – GD3128 Series Insulation Resistance Tester – HV Hipot
General Information GD3128 series Insulation Resistance Tester has perfect testing function of various insulation resistance parameters and excellent anti-interference ability, which can be used to test the insulation resistance of large capacity high voltage electrical equipment and transmission lines in strong inductive environment such as substation. The instrument adopts true color touch screen, all test data and battery power are displayed on the same screen at a glance, and the combination of knob switch and key makes the operation very simple. The user does not need to memorize the operation method. Click “HELP” on the screen to pop up the operation method, which can effectively guide the user to operate the instrument. The instrument has the function of fast disch... -
China High Quality flash point test method Factory – GDZL-50L Oil Filtration Machine – HV Hipot
General Information The machine GDZL-50L can effectively remove moisture, gas and impurities in the insulating oil, improve the pressure resistance of the oil and the quality of the oil, to ensure the safe operation of the power equipment. It is mainly used in the power sector and industrial and mining enterprises to deal with unqualified transformer oil, transformer oil, switch oil and so on. Features ● Small size and high efficiency, easy to move. It is especially suitable for live working on site. It also can dry the moisture of power equipment, and conveniently vacuum the power equipment. ● Infrared liquid level automatic control device, system pressure automatic protection device and high-efficiency degassing components are adopted in the structure. The operation is convenient and ...