Featured

  • China High Quality clamp ammeter Supplier –  GDF-3000 DC System Earth Fault Detector – HV Hipot

    China High Quality clamp ammeter Supplier – GDF-3000 DC System Earth Fault Detector – HV Hipot

    General Information In DC system, there are many earth faults including indirect earth fault, non-metal earth fault, loop earth fault, positive and negative earthing fault, positive and negative balance earth fault, multi-point earth fault. GDF-3000 Earth Fault Tester for DC System locates these earth faults and displays the parameters of system voltage, earth voltage, earth resistance and earth impedance of branches accurately. Functions ● System ground voltage measurement function, the instrument can measure the system ground voltage, negative to ground voltage, system voltage, can achieve 0-300V voltage monitoring range. ● System insulation impedance measurement function, the instrument can measure the positive to ground insulation impedance and the negative to ground insulatio...
  • China High Quality Power Factor Capacitor Factories –  VLF AC Hipot Test Set 80kV – HV Hipot

    China High Quality Power Factor Capacitor Factories – VLF AC Hipot Test Set 80kV – HV Hipot

    Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. AC test can be further divided into power frequency, variable frequency and 0.1Hz very low frequency test, among which the last one is highly recommended by IEC, due to its remarkable advantages. Following is a comparison for DC, Power Frequency, Variable Frequency, and 0.1Hz test. Aspects DC Power Frequency Variable Frequency 0.1Hz Equivalency poor good good good Insulation Damage strong slight slight slight Operation Safety relatively low relatively low relatively low high Wiring Difficulty complicated complicated most complicated simple Volume smallest largest large smal...
  • China High Quality Infrared Analyzer Supplier –  GD8000C SF6 Gas Leak Online Monitoring System – HV Hipot

    China High Quality Infrared Analyzer Supplier – GD8000C SF6 Gas Leak Online Monitoring System – HV Hipot

    Product Description GD8000C quantitatively leak online monitoring system is mainly used in the 35KV SF6 switch room and 500KV, 220KV, 110KV GIS room in the substation to monitor the SF6 gas leakage in the SF6 combined electrical equipment room environment and the oxygen content in the air in real time. When SF6 gas leaks, the density of SF6 gas is more than 5 times that of air, which accumulates in the lower space and causes local oxygen deficiency, that may cause major accidents. The system uses multiple sets of new high-sensitivity imported SF6-O2 sensors and temperature and humidity sensors. When the indoor SF6 and O2 concentrations change slightly, the sensors can respond to these changes immediately, even if the SF6 concentration is 10ppmv can be effectively monitored. The conce...
  • China High Quality 3 phase power monitor Exporters –  GDPQ-300E Power Quality Analyzer – HV Hipot

    China High Quality 3 phase power monitor Exporters – GDPQ-300E Power Quality Analyzer – HV Hipot

    Introduction GDPQ-300E Power Quality Analyzer is a portable device of testing and analyzing power system operation quality. It monitors and collects data in long running time, also provides harmonic analysis and power quality analysis. Meanwhile, it equips with data analysis software, by which the measure data can be uploaded to PC.   Features ● ARM and DSP, 16M byte memory. ● Touch screen, more easy and convenient. ● Data measuring and saving, can be uploaded to PC. ● Module structure, reasonable design and reliable operation. ● Easy and convenient software upgrading. ● Detailed analysis of measure data by power quality data analysis software in PC. Basic functions Meter detection functions No Items Description 1 Voltage/Current/Frequency It can measure three-phase volt...
  • China High Quality relay test equipment Exporters –  GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot

    China High Quality relay test equipment Exporters – GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot

    Features ● Output up to 6-phase voltage 6-phase current, which can be combined to realize conventional 4-phase voltage 3-phase current type, 6-phase voltage type, 6-phase current type, and 12-phase output mode. ● High-performance embedded industrial control computer and 8.4-inch large-screen high-resolution color TFT liquid crystal display, which can provide rich and intuitive information, including the current working status of the device, next working tips and various help information; ● The output uses a high-fidelity, high-reliability modular linear power amplifier instead of a switch-type power amplifier for superior performance. It will not generate high and medium frequency interference to the test site, and it will ensure excellent waveform smoothing and accuracy from high cu...
  • China High Quality Primary Injection Tester Ac Exporters –  GDHL-200B / GDHL-500B / GDHL-600B Contact Resistance Tester (Microhm meter) – HV Hipot

    China High Quality Primary Injection Tester Ac Exporters – GDHL-200B / GDHL-500B / GDHL-600B Contact Resistance Tester (Microhm meter) – HV Hipot

    Features ● Output high-current continuously. ● Quick and accurate test. Test current is generated from high-precision 100A/200A switching mode constant current power supply, no need for manual adjustment. ● Adopts four-terminal wiring method. The influence of test line resistance on test results is effectively eliminated. ● Stable performance. There is over-heat protection crcuit designed for long-time working. ● Light weight, easy to carry and operate. Specifications GDHL-500B Contact Resistance Tester (Micro-ohm Meter) Specifications Accessories Main unit   1 set  Test wire 4 pieces Power cord 1 piece Print paper 2 rolls Ground cable 1 piece User’s guide 1 copy Test Report 1 copy GDHL-600B Contact Resistance Tester (Micro-oh...
  • OEM Best Partial Discharge Test Equipment Factory –  Partial Discharge Online Monitoring System of GIS – HV Hipot

    OEM Best Partial Discharge Test Equipment Factory – Partial Discharge Online Monitoring System of GIS – HV Hipot

    General Information Gas-insulated metal-enclosed switches (GIS) and gas-insulated metal-enclosed transmission lines (GIL) are one of the most important devices in the power system. They have the dual tasks of control and protection. If they failed during operation and the problem cannot be solved timely,it will cause serious damage to the grid. Partial discharge fault is a common fault type of GIL/GIS. It is necessary to use GIS partial discharge online monitoring and fault location system to perform real-time online monitoring of GIL/GIS partial discharge signals and analyze and process the measured data and real time give comprehensive judgment of insulation status. Then repair schedule can be arranged according to the monitoring results to avoid major grid accidents caused by equi...
  • OEM Best Micro Ohm Measurement. Factories –  GDZK-IV Vacuum Degree Tester for Vacuum Breaker – HV Hipot

    OEM Best Micro Ohm Measurement. Factories – GDZK-IV Vacuum Degree Tester for Vacuum Breaker – HV Hipot

    Features ● Measure vacuum degree in vacuum interrupter for every types of breakers. ● Electromagnetic measuring method, Accurate and Reliable. ● No need to dismantle the vacuum breaker in measurement. ● 128*64 pixel LCD screen, easy to operate. The test results are directly compared with the standard values to determine whether they are qualified;Save, print and check testing data. ● RS-232 port, connecting with PC to download vacuum degree-ionic current curve, to estimate lifespan. ● Light weight, Portable. Specifications ● Power Supply: AC220V ± 20%, 50Hz. ● Testing Range: 10-5 ~10-1Pa. ● Electric field Voltage: 20kV. ● Magnetic field Voltage: 1600V. ● Accuracy: 20%-25% at 10-5 ~10-4. 15%-20% at 10-4 ~10-3 10%-15% at 10-3 ~10-2 5%-10% at 10-2 ~10-1 ● Ambient Temperature:  -1...
  • OEM Best Series Of Capacitors Factories –  Partial Discharge Test System GDYT series – HV Hipot

    OEM Best Series Of Capacitors Factories – Partial Discharge Test System GDYT series – HV Hipot

    GDYT is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It widely used in electrical manufacturing, power operation departments, research institutes and universities. It includes below components 1. Hipot Test Control Unit GDYD       2. PD-free Gas type transformer YDQW   3. Coupling capacitor       4. Protective resistor              5. Isolation filter LBQ                    6. Partial discharge detector  Features ● Advanced PD-free epoxy insulating tube, small partial discharge capacity. ● Low impedance voltage, better than national standard. ● Automatic co...
  • China High Quality Spray Gas Leak Detector Manufacturer –  GDWS-311CM SF6 Gas Dew Point Tester (Chilled Mirror Method) – HV Hipot

    China High Quality Spray Gas Leak Detector Manufacturer – GDWS-311CM SF6 Gas Dew Point Tester (Chilled Mirror Method) – HV Hipot

    General Information GDWS-311CM is ideal instrument when it is necessary to test water content of SF6 gas. The core component sensor is produced by GE company. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of gas moisture test instrument. Application ● Moisture monitoring of SF6 gas electrical equipment for electric power. ● SF6 gas cylinder gas quality test  ● High purity gas manufacturing  ● Semiconductor industry dry gas supply ● Research and development use ● Clean room/dry house monitoring   ● Metal heat treatment site and laboratory industrial gas humidity detection, such as air, CO2, N2, H2, O2, SF6, He, Ar and other inert gases. Features ● Better than ±2℃ measurement accuracy.  ● The whole chan...
  • China High Quality Primary Current Injection Test Kit Manufacturer –  GDHL-100A Micro-Ohmmeter – HV Hipot

    China High Quality Primary Current Injection Test Kit Manufacturer – GDHL-100A Micro-Ohmmeter – HV Hipot

    General Information GDHL-100A Micro-Ohmmeter is widely used to measure loop resistance and contact resistance for weld joints, cables, and various HV switches within power industry. It uses intelligent power test system “Smart-Quick”, which is granted software copyright, and advanced detection technology. Features ● Adopt high-precision constant current power supply, automatic rising current mode without manual adjustment, the test is fast and accurate. ● Use four-terminal wiring method, effectively eliminate the interference produced by test cable resistance; ● Wide range, high accuracy, the resistance measurement range is up to 99mΩ. ● Multiple test times can be set, which meets various on-site applications; ● Large current output for a long time, burning the switch ...
  • China High Quality Cable Locator Price Factory –  GD-4136H Cable Fault Locating System  – HV Hipot

    China High Quality Cable Locator Price Factory – GD-4136H Cable Fault Locating System – HV Hipot

    GD4136H Cable Fault system is an important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1.GD-2131H Impulse Generator 2.GD-4132 Cable Fault Locator 3.GD-4133 Multi-pulse Cable Fault Detector 4.GD-4133S Multi-pulse Coupler 5.Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-4133 Cable Fault Tester, there are two locating ways: a. Low vol...