Featured

  • China High Quality how to measure flash point Exporters –  GDZL-50L Oil Filtration Machine – HV Hipot

    China High Quality how to measure flash point Exporters – GDZL-50L Oil Filtration Machine – HV Hipot

    General Information The machine GDZL-50L can effectively remove moisture, gas and impurities in the insulating oil, improve the pressure resistance of the oil and the quality of the oil, to ensure the safe operation of the power equipment. It is mainly used in the power sector and industrial and mining enterprises to deal with unqualified transformer oil, transformer oil, switch oil and so on. Features ● Small size and high efficiency, easy to move. It is especially suitable for live working on site. It also can dry the moisture of power equipment, and conveniently vacuum the power equipment. ● Infrared liquid level automatic control device, system pressure automatic protection device and high-efficiency degassing components are adopted in the structure. The operation is convenient and ...
  • OEM Best pd test of transformer Manufacturers –  GDJF-2006 Partial Discharge Analyzer – HV Hipot

    OEM Best pd test of transformer Manufacturers – GDJF-2006 Partial Discharge Analyzer – HV Hipot

    Features ● With high speed, big capacity data acquisition card. Continuously collect partial discharge data, good repeatability, and high accuracy. ● Functions of testing, analyzing (multi-parameter analysis, two-dimension atlas analysis, three-dimension atlas analysis), data storage, report, and print. Display waveform (ellipse, sine wave, line), discharge value and test voltage. ● Suitable for 50Hz, 150Hz frequency power supply, up to 400Hz. Automatic tracking external power supply frequency. ● Big color LCD screen. Large memory, with USB port. ● With anti-false operation function. Automatic adjusting gain during testing and rectifying. ● Anti-interference design. Specifications ● Capacitance range: 6pF-250μF ● Sensitivity: <0.02pc (capacitance at 50pF)                   ● Am...
  • OEM Best megger unit Factory –  GD3128 Series Insulation Resistance Tester – HV Hipot

    OEM Best megger unit Factory – GD3128 Series Insulation Resistance Tester – HV Hipot

    General Information GD3128 series Insulation Resistance Tester has perfect testing function of various insulation resistance parameters and excellent anti-interference ability, which can be used to test the insulation resistance of large capacity high voltage electrical equipment and transmission lines in strong inductive environment such as substation. The instrument adopts true color touch screen, all test data and battery power are displayed on the same screen at a glance, and the combination of knob switch and key makes the operation very simple. The user does not need to memorize the operation method. Click “HELP” on the screen to pop up the operation method, which can effectively guide the user to operate the instrument. The instrument has the function of fast disch...
  • OEM Best isolation test Manufacturers –  Online Monitoring System of Circulating Current on Cable Sheath GDCO-301 – HV Hipot

    OEM Best isolation test Manufacturers – Online Monitoring System of Circulating Current on Cable Sheath GDCO-301 – HV Hipot

    General Information Cables above 35kV are mainly single-core cables with metal sheath. Since the metal sheath of the single-core cable is hinged with the magnetic field line generated by the AC current in the core wire, the two ends of the single-core cable have a high induced voltage. Therefore, appropriate grounding measures should be taken to keep the induced voltage within the safe voltage range (usually no more than 50V, but no more than 100V with safety measures). Usually, the metal sheath of short line single-core cable is grounded directly at one end and grounded through gap or protection resistor at the other end. The metal sheath of long line single – core cable is grounded by three – phase segmental cross – connection. No matter which kind of grounding me...
  • OEM Best alat ukur megger Supplier –  Dielectric Loss Tester for Live Capacitive Equipment GDDJ-HVC  – HV Hipot

    OEM Best alat ukur megger Supplier – Dielectric Loss Tester for Live Capacitive Equipment GDDJ-HVC – HV Hipot

    General Information There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. If the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be found in ...
  • OEM Best protective relay tester Supplier –  GDJB-6000M Smart Substation Relay Protection Test System – HV Hipot

    OEM Best protective relay tester Supplier – GDJB-6000M Smart Substation Relay Protection Test System – HV Hipot

    GDJB-6000M Smart Substation Relay Protection Test System is a new generation of intelligent relay protection tester designed according to “Smart Substation Relay Protection Technical Specifications” and “Smart Substation Technical Guidelines”. It can not only realize the full function test of the optical digital protection device (IEC61850, smart digital station), but also carry out full function test on the traditional protection device (conventional station). GDJB-6000M is a portable new product independently developed through the use of technologies such as embedded real-time operating systems, high-performance embedded processors, and large-scale logic devices, combined with power field conditions and numerous power user experiences. It is widely applicable t...
  • China High Quality power usage meter test Exporters –  GDYM-1A Single Phase Electric Energy Meter Calibrator – HV Hipot

    China High Quality power usage meter test Exporters – GDYM-1A Single Phase Electric Energy Meter Calibrator – HV Hipot

    Product Description GDYM-1A Single phase Electric Energy Meter Calibrator is multi-parameter measuring instrument which is full digital, mullti-function and high precision. It is not only enable to calibrating the error, but also to measure voltage, current effective value, active power, reactive power, apparent power, power frequency, power factor, phase relationship, etc. It is especially suitable for calibrating the measurement accuracy of Single-phase electric energy meter in the power supply unit. Simple and quick operation, all operating procedures are displayed on the screen. Features ● To calibrate the electric energy meter of measuring system and measure the low voltage ratio. ● Using latest 32 bit 150MHz DPS core technology, 16 bit high precision converter, the error is ...
  • China High Quality Test Vacuum Breaker Manufacturer –  GDGK-501 DC Power Supply – HV Hipot

    China High Quality Test Vacuum Breaker Manufacturer – GDGK-501 DC Power Supply – HV Hipot

    Features ● Using contact regulators to output voltage and rectify by rectifier bridge. ● The output voltage is continuous adjusted. ● Thermal cut-outs for short-circuit protectors at DC output. ● Small size, light weight. Specifications ● Input Voltage: AC220V±10%, 50Hz, single phase ● Capacity: 3kVA ● Output Voltage: AC 0-260V DC 0-360V ripple: 3% ● Output Current: 10A (continuous), 20A(short time) ● 24vdc, 48vdc, 110vdc, and 250vdc, 15A ● Maximum load current: 20A ● Accuracy: 1.5% of the range ● Temperature: -10℃-45℃, humidity: <80% ● Dimension: 440*340*240 mm ● Weight: 18kg Accessories Test Box 1 set Power cord 1 piece Ground wire 1 piece Test wire 6 pieces Manual 1 piece Factory test report 1 copy Packing list 1 copy
  • China High Quality Digital Cable Meter Exporters –  GDCF-900T Vehicle Mounted Cable Fault Locating System – HV Hipot

    China High Quality Digital Cable Meter Exporters – GDCF-900T Vehicle Mounted Cable Fault Locating System – HV Hipot

    Vehicle Mounted Cable Fault Locator system is used for Cable Fault conditioning (burn-down), Pre-Location, Route Location, Pin-pointing & Testing of HV & LV cables of different types&sizes. The set is suitable to carrying out the above-mentioned multifunction on power cables of various voltage levels mainly 33KV, 11KV, 415V and control cables with 1.1 KV grade. The set shall be used for cable types namely XLPE, PVC, PILC with Al / Cu conductor. The cables are laid underground (under plain earth, trenches, or RCC surface, Horizontal Drilling in HDD Pipe), above ground or partly under & partly above ground with maximum cable length around 25Km. The cable fault locator is suitable for fault locating and pinpointing the following types of cable faults. ● High resistance ● L...
  • OEM Best Cable Locater Depth Measurement Suppliers –  GDCF-900T Vehicle Mounted Cable Fault Locating System – HV Hipot

    OEM Best Cable Locater Depth Measurement Suppliers – GDCF-900T Vehicle Mounted Cable Fault Locating System – HV Hipot

    Vehicle Mounted Cable Fault Locator system is used for Cable Fault conditioning (burn-down), Pre-Location, Route Location, Pin-pointing & Testing of HV & LV cables of different types&sizes. The set is suitable to carrying out the above-mentioned multifunction on power cables of various voltage levels mainly 33KV, 11KV, 415V and control cables with 1.1 KV grade. The set shall be used for cable types namely XLPE, PVC, PILC with Al / Cu conductor. The cables are laid underground (under plain earth, trenches, or RCC surface, Horizontal Drilling in HDD Pipe), above ground or partly under & partly above ground with maximum cable length around 25Km. The cable fault locator is suitable for fault locating and pinpointing the following types of cable faults. ● High resistance ● L...
  • China High Quality megger earth tester price Supplier –  GD2000D Insulation Resistance Tester – HV Hipot

    China High Quality megger earth tester price Supplier – GD2000D Insulation Resistance Tester – HV Hipot

    General Information GD2000D digital insulation resistance tester produced by our company uses an embedded industrial single chip real-time operating system. The digital analog pointer and digital field code display are perfectly combined. This series of meters has a variety of voltage output levels (250V, 500V, 1000V, 2500V, 5000V, 10000V), large capacity, strong anti-interference, analog pointer and digital synchronous display, AC and DC dual-use, simple operation, automatic calculation of various insulation indicators (absorption ratio, polarization index), various measurement results with anti-power-down function, etc. It is an ideal test instrument for measuring the insulation resistance of large-capacity transformers, transformers, generators, high-voltage motors, power capacito...
  • China High Quality pd detector Supplier –  GDPD-306M Portable Ultrasonic Partial Discharge Detector – HV Hipot

    China High Quality pd detector Supplier – GDPD-306M Portable Ultrasonic Partial Discharge Detector – HV Hipot

    GDPD-306M is widely used in the partial discharge detection of power systems. Including high voltage switchgear, ring mains, voltage/current transformer, transformer (include dry type transformer), GIS, overhead lines, cables, and other equipment insulation state detection. The following indicators are used to measure the degree of discharge of electrical equipment: Partial discharge intensity detection: By measuring the discharge signal in a power frequency cycle, the intensity of the partial discharge is characterized according to the maximum value (dB) in the discharge pulse sequence. Partial discharge frequency detection: The device measures the discharge signal within a power frequency cycle, extracts the discharge pulses and characterizes the frequency of partial discha...