Featured

  • OEM Best Capacitor Specifications Supplier –  VLF AC Hipot Test Set 80kV – HV Hipot

    OEM Best Capacitor Specifications Supplier – VLF AC Hipot Test Set 80kV – HV Hipot

    Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. AC test can be further divided into power frequency, variable frequency and 0.1Hz very low frequency test, among which the last one is highly recommended by IEC, due to its remarkable advantages. Following is a comparison for DC, Power Frequency, Variable Frequency, and 0.1Hz test. Aspects DC Power Frequency Variable Frequency 0.1Hz Equivalency poor good good good Insulation Damage strong slight slight slight Operation Safety relatively low relatively low relatively low high Wiring Difficulty complicated complicated most complicated simple Volume smallest largest large smal...
  • China High Quality Voltage Ac Exporters –  DC Hipot Test Set GDZG-S – HV Hipot

    China High Quality Voltage Ac Exporters – DC Hipot Test Set GDZG-S – HV Hipot

    Features ● Electronic control and tune, easy to operate. ● The date of voltage and current are recorded in the panel, reading without conversion. ● One minute timing and tip function. ● Perfect overvoltage and over-current protection function inside, also zinc oxide overvoltage protection outside, which ensure safety of generator. ● Both control unit and doubler packed with special shockproof aluminum alloy cabinet, easy to move. ● Portable design, suitable for on-site testing. Specifications Items(kV/mA) parameter 50/100 50/120 60/150 60/200 60/300 Output voltage(kV) 50 50 60 60 60 Output current(mA) 100 120 150 200 300 Output power(W) 5000 6000 9000 12000 18000 Voltage measurement error ≤1.0% ±1digit Current measu...
  • China High Quality protection relays used in substation Factories –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot

    China High Quality protection relays used in substation Factories – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot

    Features A. Working conditions 1. Power supply: AC 220V±10%,50Hz 2. Working environment: Temperature -10℃~40℃; Humidity: ≤85% 3. Atmosphere: 86-106kPa B. Output power supply 1. AC voltage: 0-220V/3A  Adjustable 2. AC current: 0-100A/7V (200A can be customized);  0-20A/25V  Adjustable; 0-5A/5V  Adjustable 3. DC voltage: 0-220V/3A  Adjustable 4. DC current:0-20A/25V 5. Fixed voltage output: DC 24V/48V/110V/220V 6. Current/Voltage accuracy: ±1%. C. Performance Index 1. Ammeter and voltmeter: 41/2 digit. 2. Digital millisecond meter: 0-99.9999s(999.999s can be customized) Resolution: 0.1ms. D. Functions 1. Measure relay: Measure start value, return value and drop-off to pick-up ratio of current, voltage relay. 2. Time relay: Measure start value, return value and action time. 3. Intermed...
  • China High Quality battery discharge tester Factories –  Battery Charge and Discharge Load Bank GDCF – HV Hipot

    China High Quality battery discharge tester Factories – Battery Charge and Discharge Load Bank GDCF – HV Hipot

    Features ● All in one function. Charging, discharging, single-unit detection, online monitoring, and activation. ● Intelligent three-stage charging, constant current discharge, real-time online tour to detect each cell parameter. ● The power consumption component adopts alloy resistance, which is safe, no red heat and longtime life. ● Support U disk, make data transfer more easily. ● U Disk and RS232 interface make it easy to communicate with computer. ● Portable design, convenient for users with strong mobility. Specification Item Model 48V30A 110V100A 220V30A 380V20A Discharge total voltage 10~60V 98~121V 176~275V 304~456V Charge total voltage output 43~60V 99~121V 176~264V 304~456V Charge & discharge current 0~50A 0~100A 0~30A 0~20A Access load voltage 48V 110V...
  • China High Quality Safely Discharge Capacitor Manufacturer –  VLF AC Hipot Test Set – HV Hipot

    China High Quality Safely Discharge Capacitor Manufacturer – VLF AC Hipot Test Set – HV Hipot

    Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. AC test can be further divided into power frequency, variable frequency and 0.1Hz very low frequency test, among which the last one is highly recommended by IEC, due to its remarkable advantages. Following is a comparison for DC, Power Frequency, Variable Frequency, and 0.1Hz test. Aspects DC Power Frequency Variable Frequency 0.1Hz Equivalency poor good good good Insulation Damage strong slight slight slight Operation Safety relatively low relatively low relatively low high Wiring Difficulty complicated complicated most complicated simple Volume smallest largest large smal...
  • OEM Best Waveform Generator Suppliers –  Impulse Voltage Test System – HV Hipot

    OEM Best Waveform Generator Suppliers – Impulse Voltage Test System – HV Hipot

    Features ● Complete equipment and wide voltage levels in the whole set of device. ● Small electric inductance in the return circuit of the impulse voltage generator, A band-stop filtering is adopted so that a standard impulse wave is still generated even under a large capacity load, and large load capacity. ● Large in voltage utilization coefficient. ● Convenient in wave adjustment, simple in operation, excellent in synchronization performance and reliable in motion. ● An automatic control technique is adopted in the constant-current charge, which is high automation and strong anti-interference capacity. ● A digital measurement and analysis system for the impulse test date are adopted, which increase the technical level and the efficiency of the impulse voltage tests. Specifications ...
  • China High Quality Earth Leakage Circuit Breaker Manufacturer –  GDKC-12A (GDKC-12B) (GDKC-13A) Circuit Breaker Analyzer 2021 – HV Hipot

    China High Quality Earth Leakage Circuit Breaker Manufacturer – GDKC-12A (GDKC-12B) (GDKC-13A) Circuit Breaker Analyzer 2021 – HV Hipot

    General Information High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-12A/B (GDKC-13A) is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy.  Features ● Time: the open/close time, in phase synchronization, phase-to-phase synchronization of 12contacts. ● Closing resistor: pre-switching time, pre-switching waveform and resistance of the closing resistor of 6 channels. ● Reclosure: close-open, open-close, open-close-open time for each contact. ● Bounce: close bounce time, times, process and waveform of each contacts. ● Velocity: velocity at contact open or close, maximum speed, time-travel characteristic curve; first open, first close and second open velocity of reclo...
  • China High Quality High Voltage Meter Supplier –  GDBT-1000kVA Transformer Test Bench – HV Hipot

    China High Quality High Voltage Meter Supplier – GDBT-1000kVA Transformer Test Bench – HV Hipot

    General Information Test Object: 22.9kV Single Phase transformers and special transformers, load voltage and current: AC 0-650V/78A, AC 0-1200V/29A, AC 0-2400V/14.6A The impedance of tested transformer is within 7%, HV side is 23kV, 11kV, 6kV. LV side is 0.05kV-2.4kV. This test bench can conduct below test: 1. No-load test including no-load loss, the percent of no-load current to rated current. 2. Load test including load loss, impedance voltage percentage, automatic temperature conversion and load loss test under 30% or above full current. 3. Induced voltage test. Features ● Manual record test data and save in the database. ● The data of No-load test can be corrected by waveform and rated voltage automatically. ● The data of Load test can be corrected by temperature (75℃, 100℃, 1...
  • China High Quality resistance tester electrical Manufacturer –  GD2000D Insulation Resistance Tester – HV Hipot

    China High Quality resistance tester electrical Manufacturer – GD2000D Insulation Resistance Tester – HV Hipot

    General Information GD2000D digital insulation resistance tester produced by our company uses an embedded industrial single chip real-time operating system. The digital analog pointer and digital field code display are perfectly combined. This series of meters has a variety of voltage output levels (250V, 500V, 1000V, 2500V, 5000V, 10000V), large capacity, strong anti-interference, analog pointer and digital synchronous display, AC and DC dual-use, simple operation, automatic calculation of various insulation indicators (absorption ratio, polarization index), various measurement results with anti-power-down function, etc. It is an ideal test instrument for measuring the insulation resistance of large-capacity transformers, transformers, generators, high-voltage motors, power capacito...
  • OEM Best High Voltage Capacitor Tester Supplier –  50kV AC DC Dielectric Test Equipment GDYD-53D – HV Hipot

    OEM Best High Voltage Capacitor Tester Supplier – 50kV AC DC Dielectric Test Equipment GDYD-53D – HV Hipot

    Application AC hi-pot testing is the effective and direct way to test insulation strength for electrical equipment, apparatus, or machines. It checks dangerous flaws which assure electrical equipment continuous working. Typical applications include testing of transformers, switchgear, cables, capacitors, aerial motors platforms, hot sticks bucket bricks, vacuum bottles and other related equipment like vacuum interrupters, blankets, ropes, gloves, hydraulics hose, instruments transformers generators. Features ● Digital display panel mounted controls & indicators with easy-to-read legend. ● Monitoring high voltage side voltage, low voltage side current and indicator of zero, power, working start, timing. ● Over-current protection, zero-starting protection, sound, and light alarm...
  • China High Quality Sine Waves Generator Manufacturer –  GDCY-20B 20kV Impulse Voltage Tester (Basic Type) – HV Hipot

    China High Quality Sine Waves Generator Manufacturer – GDCY-20B 20kV Impulse Voltage Tester (Basic Type) – HV Hipot

    GDCY-12B Programmable Automatic Impulse Voltage Tester is mainly based on TB/T 2653, GB/T 17627, GB/T 16927, GB14048, GB7251, GB/T 16935, IEC 61730, GB4706, GB3048, JB/T 7083 and other standard requirements. It is mainly used for safety performance (dielectric performance) detection of low-voltage electrical appliances, high and low voltage switches, solar energy, electricity meters, relays, leakage protectors, etc. The impulse output can be controlled by computer, and the test report can be printed and generated.  (Picture only for reference first.) Features ● Manual/automatic/programmable mode: Manual mode adjusts impulse voltage manually by adjusting knob; Automatic mode adjusts impulse voltage automatically by the system; Programmable mode uses computer to control impulse vo...
  • OEM Best Cable Wire Tester Factories –  GD-4138H Cable Fault Locating System – HV Hipot

    OEM Best Cable Wire Tester Factories – GD-4138H Cable Fault Locating System – HV Hipot

    GD-4138H Mobile Cable Fault Locating System is important tool to maintain all kinds of cables. It is compatible equipment that can trace, locate the underground cables, with fault distance measurement and HV generation. As it is movable device, it is convenient to carry on-site. If acoustic locator is used together, it can locate accurate position of cable fault point. Application is underground cable, aerial cable, power cable, local cable, communication cable and fiber cable. Typical fault to be detected includes ● High impedance flash-over fault ● High impedance leak ● High/low resistive grounding ● Short-circuit fault ● Open-circuit fault ● Poor connection/Disconnection GD-4138L system includes ● GD-4138H main frame (Coupling device, Sphere gap, HV generator are inside) ● GD-...