Featured

  • China High Quality Arbitrary Waveform Factories –  GDBR-P Transformer Load, No-load and Capacity Tester – HV Hipot

    China High Quality Arbitrary Waveform Factories – GDBR-P Transformer Load, No-load and Capacity Tester – HV Hipot

    Features ● Measure transformer No-load current, No-load loss, short circuit voltage, short circuit loss and capacity. ● Three meters testing methods. ● When making three phase transformer No-load, load test, the instrument will judge if the wiring is correct automatically, and shows three phase voltage, current vector diagram. ● Finish load test under 1600kVA below distribution transformer full current for single machine. Finish 2500kVA below distribution transformer load test under 1/3 rated current (Under 1/3 rated current, the instrument can be converted to load loss parameters under rated current.) ● All test results are corrected automatically. The instrument automatic correction as follows, waveform correction, temperature correction, Non rated voltage correction and non rated ...
  • China High Quality Primary Injector Test Manufacturer –  GMDL-02A HV Circuit Breaker Analog Device – HV Hipot

    China High Quality Primary Injector Test Manufacturer – GMDL-02A HV Circuit Breaker Analog Device – HV Hipot

    General Information GMDL-02A high-voltage circuit breaker simulation device is manufactured using the principles of large-scale field programmable gate arrays, power electronic devices with protection, etc. The open coil is designed according to an independent loop, which can simulate the three-phase and split-phase operation of the voltage level of 6-110KV. The action behavior of the single open coil circuit breaker is suitable for the selection of power systems, industrial and mining enterprises, scientific research institutes, professional colleges, and protection manufacturers. It is used as a substitute for actual circuit breakers in the transmission test of the entire system of relay protection and automatic devices with switches. The action is accurate, reliable, and the numbe...
  • China High Quality harga megger digital 10.000 volt kyoritsu Supplier –  GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot

    China High Quality harga megger digital 10.000 volt kyoritsu Supplier – GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot

    General Information GD3126A  (GD3126B) Insulation Resistance Tester is widely used in maintenance of electrical equipment in transformer substation, power plant, etc. It is suitable for carrying out measurement of insulation resistance (IR), absorption ratio (DAR), polarization index (PI), leakage current (Ix) and absorption capacitance (Cx) of all kinds of high voltage equipment, including switchgear, transformers, reactors, capacitors, motors, generators and cables, etc. Features ● Adopts microcomputer control, menu operation and large LCD screen dot matrix display with stable performance. ● Strong anti-interference ability, suitable for measuring in strong electromagnetic interference environment. ● Large capacity, can meet the requirements of high voltage, high resistance, lar...
  • China High Quality analogue insulation tester 5kv Suppliers –  GDCR1000C Non-contact Phase Sequence Tester – HV Hipot

    China High Quality analogue insulation tester 5kv Suppliers – GDCR1000C Non-contact Phase Sequence Tester – HV Hipot

    General Information GDCR1000C, GDCR1000D non-contact phase tester is a major breakthrough in traditional phase sequence detection method. The traditional phase sequence detection is to strip the connection pole of three-phase wires, connect three bare clamps or test needles of phase sequence meter to three bare fire lines, while GDCR1000C and GDCR1000D adopt pincers non-contact induction measurement. The phase sequence can be detected by no need peeling off the wire and without touching the bare high-voltage fire wire, just directly clamping three super-inductive high-insulation clamps on the insulation skin of the three-phase fire wire respectively. At the same time, acousto-optic indication of the positive or reverse phase state of the phase sequence of the three-phase power supply...
  • China High Quality Ac Withstand Test Manufacturers –  50kV AC DC Dielectric Test Equipment GDYD-53D – HV Hipot

    China High Quality Ac Withstand Test Manufacturers – 50kV AC DC Dielectric Test Equipment GDYD-53D – HV Hipot

    Application AC hi-pot testing is the effective and direct way to test insulation strength for electrical equipment, apparatus, or machines. It checks dangerous flaws which assure electrical equipment continuous working. Typical applications include testing of transformers, switchgear, cables, capacitors, aerial motors platforms, hot sticks bucket bricks, vacuum bottles and other related equipment like vacuum interrupters, blankets, ropes, gloves, hydraulics hose, instruments transformers generators. Features ● Digital display panel mounted controls & indicators with easy-to-read legend. ● Monitoring high voltage side voltage, low voltage side current and indicator of zero, power, working start, timing. ● Over-current protection, zero-starting protection, sound, and light alarm. ● Co...
  • China High Quality Combustion Gas Analyzer Exporters –  GDWG-V SF6 Gas Leak Detector (IR type, Double display) – HV Hipot

    China High Quality Combustion Gas Analyzer Exporters – GDWG-V SF6 Gas Leak Detector (IR type, Double display) – HV Hipot

    Product Description GDWG-V SF6 Gas Leak Detector is infrared red type leak detector (NDIR technology) with double display. It is color INCELL TFT display and real-time shows SF6 concentration. It rapidly detects SF6 breaker, GIS leakage point and yearly leakage rate qualitatively and quantitatively. It is a good device suitable for power supply department, installation and overhaul unit, power test institute. Application ● High Voltage Switch Equipment ● Rotor vane of helicopter ● Gas transmission system ● To detect fire extinguisher ● Ventilation efficiency research of Buildings ● To detect danger Advantages ● No radiation. ● No need to replace high pressure high pure argon gas regularly. ● No need to approach high pressure gas. ● No need to replace sensors regularl...
  • China High Quality Capacitor Discharge Time Factory –  AC High Voltage Test Sets for GIS – HV Hipot

    China High Quality Capacitor Discharge Time Factory – AC High Voltage Test Sets for GIS – HV Hipot

    Applications ● Transformer ● GIS system ● SF6 switchgear ● Cables ● Bushing ● Insulator ● CT/PT ● Other capacitive devices Features ● Small temperature rises at rated load. Dry or Oil type reactors, high mechanical strength, good insulation, nice and reliable. ● Adjustable capacity of frequency control source. Strong protection, good stability. With multiple working mode, easy to operate. ● With 220V or 380V single phase power, convenient for on-site power sourcing. ● Flexible configuration. Different type reactors for optional, meet different test object requirements. Multifunctional, cost effective. Specifications ● Rated output voltage: based on different test objects. ● Output frequency: 20- 300Hz. ● Waveform: pure sine wave, THD <1.0%. ● Max. capacity: 1000kVA and below. ● Duty ...
  • OEM Best Testing For Gas Leaks Exporters –  GDWG-IV  SF6 Gas Leak Detector(IR series) – HV Hipot

    OEM Best Testing For Gas Leaks Exporters – GDWG-IV SF6 Gas Leak Detector(IR series) – HV Hipot

    Product Description GDWG-IV SF6 Gas Leak Detector is infrared red type leak detector(NDIR technology). It is color OLED display and real-time shows SF6 concentration. It rapidly detect SF6 breaker, GIS leakage point and yearly leakage rate qualitatively and quantitatively. It’s a good device suitable for power supply department, installation and overhaul unit, power test institute. Application ● High Voltage Switch Equipment ● Rotor vane of helicopter ● Gas transmission system ● To detect fire extinguisher ● Ventilation efficiency research of Buildings ● To detect danger Advantages ● No radiation. ● No need to replace high pressure high pure argon gas regularly. ● No need to approach high pressure gas. ● No need to replace sensors regularly, cost-effective. ● Stable ...
  • China High Quality insulation tester megger price Manufacturers –  GD2000D Insulation Resistance Tester – HV Hipot

    China High Quality insulation tester megger price Manufacturers – GD2000D Insulation Resistance Tester – HV Hipot

    General Information GD2000D digital insulation resistance tester produced by our company uses an embedded industrial single chip real-time operating system. The digital analog pointer and digital field code display are perfectly combined. This series of meters has a variety of voltage output levels (250V, 500V, 1000V, 2500V, 5000V, 10000V), large capacity, strong anti-interference, analog pointer and digital synchronous display, AC and DC dual-use, simple operation, automatic calculation of various insulation indicators (absorption ratio, polarization index), various measurement results with anti-power-down function, etc. It is an ideal test instrument for measuring the insulation resistance of large-capacity transformers, transformers, generators, high-voltage motors, power capacito...
  • China High Quality battery tester with printer Factory –  Battery Impdeance Tester GDBT-8612 – HV Hipot

    China High Quality battery tester with printer Factory – Battery Impdeance Tester GDBT-8612 – HV Hipot

    General Information  As a key component of the power system, batteries must be tested and maintained annually, quarterly or even monthly and their test data needs to be analyzed on a regular basis. Practice has proved that there is no correlation between voltage and capacity, because the voltage only reflects the surface parameters of the battery. Internationally, tests for conductance or internal resistance have been widely used in the routine maintenance of batteries to replace the previous voltage check method. Because the conductance or internal resistance is a parameter that reflects the internals of the battery, the conductance or internal resistance of the battery has been recognized as an important parameter for accurately and quickly determining the health of the battery. Th...
  • China High Quality Voltage Ac Factories –  Turn-to-turn Surge Tester – HV Hipot

    China High Quality Voltage Ac Factories – Turn-to-turn Surge Tester – HV Hipot

    GDZJ-10S Turn to Turn Surge Withstand Testerh GDZJ-10S is used to test turn-to-turn insulation strength of single phase motor, 3-phase motor, Micro motor, Special motor, electrical motor, transformer (including switching mode power supply transformer), relay and winding electrical equipment. Features It can detect below faults: ● Turn-to-turn Insulation breakdown ● Corona discharge ● Winding connection mistake ● Winding disconnection ● Turn-to-turn difference ● Short-circuit between inter-phase, winding phase, or iron core Specifications ● Peak voltage: 500-10kV continuous adjustment ● Peak error: ≤ 5%(1kV-5kV) ● Waveform rising time: 0.5μS or 0.2μS ● Power supply: 220V±10%, 50Hz ● Power consumption: ≤ 800 W ● Dimension: 900*460*550mm ● Weight: about 70kg Important Tips GDZJ...
  • OEM Best The Capacitors Supplier –  DC High Voltage Generator GDZG-300 – HV Hipot

    OEM Best The Capacitors Supplier – DC High Voltage Generator GDZG-300 – HV Hipot

    Features ● Simple operation and complete function, easy for wild work. ● Higher voltage stability, smaller ripple coefficient. ● More reliable and stable, continuous short-circuit discharge directly to ground. ● Intelligent grounding protection and alarm function. High precision, accurate measurement, digital display of voltmeter and ammeter, with voltage resolution 0.1kV, and current 0.1uA. ● High stability of voltage regulation, smooth voltage boosting process, high adjustable precision, with coarse and fine adjustment functions. Accuracy of voltage regulation better than 0.1%, voltage and current measurement error is less than 1.0%, ripple factor better than 0.5%. ● With function of high-accuracy 75%VDC-1mA, more convenient for zinc oxide lighting arrester DC testing. ● HV booste...