Featured

  • China High Quality Cable Location Equipment Suppliers –  GD-7018A Optical Fiber Identifier – HV Hipot

    China High Quality Cable Location Equipment Suppliers – GD-7018A Optical Fiber Identifier – HV Hipot

    The GD-7018 series optical fiber pipeline identifier can accurately locate and meaure depth of the underground pipelines, cables and optical cables under the condition of without digging, and accurately find the damage points of the outer coating of the underground pipelines and the location of the underground cable fault points. The instrument incorporates the most advanced technologies such as ultra-narrow band filter, Bluetooth wireless communication, GPS positioning, automatic data mapping by professional data analysis software and automatic generation of test reports. The detection and inspection of various kinds of metal pipelines, pipeline management and maintenance, municipal planning and construction, pipeline inspection in power supply and other departments is one of the neces...
  • China High Quality Locate Underground Cable Supplier –  GD-2134E  Cable Identifier – HV Hipot

    China High Quality Locate Underground Cable Supplier – GD-2134E Cable Identifier – HV Hipot

    GD-2134E is a high-performance underground metal pipeline detection system composed of signal transmitters and receivers. It can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables. It can carry out uniqueness identification with a variety of selected accessories, as well as pipe insulation damage and the search for some types of cable faults. Features ● Compass display: intuitively displays the pipeline location and left & right directions. ● Tracking true and false prompts: current direction measurement, tracking correct error prompts, eliminating line interference (some frequencies). ● Depth and current measurements, can display the signal strength historical curve. ● Fully digital high-precision sampling processing: sta...
  • OEM Best resistance of earthing system Factories –  GDWR-5A Earth Resistance Tester for Ground Grid – HV Hipot

    OEM Best resistance of earthing system Factories – GDWR-5A Earth Resistance Tester for Ground Grid – HV Hipot

    Product Description GDWR-5A Earth Resistance Tester is a high-precision test instrument used in various fields such as substations for testing grounding resistance and related parameters. The instrument has the characteristics of small volume, light weight, convenient carrying, strong anti-interference performance and high accuracy. The instrument is an integrated structure, built-in variable frequency power supply module, and the output power supply is continuously variable frequency adjustable. The frequency can be changed to 45Hz or 55Hz, and the built-in high-speed processor core adopts high-end digital filtering technology, which effectively avoids the interference of the power frequency electric field to the test, and fundamentally solves the problem of accurate measurement und...
  • China High Quality insulation testing megger Manufacturer –  GDF-3000A  DC System Earth Fault Detector – HV Hipot

    China High Quality insulation testing megger Manufacturer – GDF-3000A DC System Earth Fault Detector – HV Hipot

    General Information DC system insulation faults, DC mutual faults and AC power failures are faults that are prone to occur and are harmful to the power system, and endanger the normal operation of the power system. In order to better help field maintenance personnel to quickly and accurately find DC faults, our company has developed a DC fault finder by years of efforts and summing up a large number of field experiences. The DC grounding finder uses a high-precision current clamp meter to detect and locate faults using the DC current difference in the fault loop. The fast FFT transform technology is introduced into the DC fault finding device, to detect various types of insulation faults, DC mutual faults, and AC power failures in DC systems with different voltage level (24V (optiona...
  • China High Quality for measuring insulation resistance the best choice would be Manufacturers –  GDF-3000 DC System Earth Fault Detector – HV Hipot

    China High Quality for measuring insulation resistance the best choice would be Manufacturers – GDF-3000 DC System Earth Fault Detector – HV Hipot

    General Information In DC system, there are many earth faults including indirect earth fault, non-metal earth fault, loop earth fault, positive and negative earthing fault, positive and negative balance earth fault, multi-point earth fault. GDF-3000 Earth Fault Tester for DC System locates these earth faults and displays the parameters of system voltage, earth voltage, earth resistance and earth impedance of branches accurately. Functions ● System ground voltage measurement function, the instrument can measure the system ground voltage, negative to ground voltage, system voltage, can achieve 0-300V voltage monitoring range. ● System insulation impedance measurement function, the instrument can measure the positive to ground insulation impedance and the negative to ground insulatio...
  • OEM Best Wire Tester Suppliers –  GD-2136H Cable Fault Locating System – HV Hipot

    OEM Best Wire Tester Suppliers – GD-2136H Cable Fault Locating System – HV Hipot

    GD2136H Cable Fault system is important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1. GD-2131H Impulse Generator 2. GD-2132 Cable Fault Locator 3. GD-2133 Cable Fault Tester 4. Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-2133 Cable Fault Tester, there are two locating ways: a. Low voltage pulse: If only using GD-2133, open circ...
  • China High Quality circuit breaker insulation resistance test Factories –  GDJF-2006 Partial Discharge Analyzer – HV Hipot

    China High Quality circuit breaker insulation resistance test Factories – GDJF-2006 Partial Discharge Analyzer – HV Hipot

    Features ● With high speed, big capacity data acquisition card. Continuously collect partial discharge data, good repeatability, and high accuracy. ● Functions of testing, analyzing (multi-parameter analysis, two-dimension atlas analysis, three-dimension atlas analysis), data storage, report, and print. Display waveform (ellipse, sine wave, line), discharge value and test voltage. ● Suitable for 50Hz, 150Hz frequency power supply, up to 400Hz. Automatic tracking external power supply frequency. ● Big color LCD screen. Large memory, with USB port. ● With anti-false operation function. Automatic adjusting gain during testing and rectifying. ● Anti-interference design. Specifications ● Capacitance range: 6pF-250μF ● Sensitivity: <0.02pc (capacitance at 50pF)                   ● Am...
  • OEM Best resistance of earthing system Suppliers –  GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot

    OEM Best resistance of earthing system Suppliers – GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot

    General Information GD3126A  (GD3126B) Insulation Resistance Tester is widely used in maintenance of electrical equipment in transformer substation, power plant, etc. It is suitable for carrying out measurement of insulation resistance (IR), absorption ratio (DAR), polarization index (PI), leakage current (Ix) and absorption capacitance (Cx) of all kinds of high voltage equipment, including switchgear, transformers, reactors, capacitors, motors, generators and cables, etc. Features ● Adopts microcomputer control, menu operation and large LCD screen dot matrix display with stable performance. ● Strong anti-interference ability, suitable for measuring in strong electromagnetic interference environment. ● Large capacity, can meet the requirements of high voltage, high resistance, lar...
  • OEM Best beaing heater Factory –  GDJB-802 3 Phase Secondary Current Injection Relay Test Set – HV Hipot

    OEM Best beaing heater Factory – GDJB-802 3 Phase Secondary Current Injection Relay Test Set – HV Hipot

    General Information GDJB-802 3 Phase Secondary Current Injection Relay Protection Test Device plays a key role in operating electricity power systems reliably and safely. It can automatically judge over-current, over-voltage, overload, short circuit, high temperature, abnormal data and warning prompts for misoperation. In addition to the verification of various relays (such as current, voltage, inverse time, power direction, impedance, differential, low cycle, synchronization, frequency, DC, intermediate, time, etc.) and microcomputer protection, it can also simulate single-phase to Three-phase transient, permanent, and transitional faults are tested for the entire set. It can also complete various large-scale and complex calibration tasks with a high degree of automation, can automa...
  • China High Quality uhf pd sensor Manufacturer –  GDPD-3000C Portable Partial Discharge Detector – HV Hipot

    China High Quality uhf pd sensor Manufacturer – GDPD-3000C Portable Partial Discharge Detector – HV Hipot

    GDPD-3000C Portable Ultrasonic Partial Discharge Detector uses advanced cloud computing and automatic modeling technology to achieve the partial discharge signal measurement, recording, transmission, storage, analysis and exchange, providing powerful technical support for on-site measurement of partial discharge. The measurement personnel collect the partial discharge information by using GDPD-3000C, and the cloud computing can be used to intelligently diagnose the insulation state of detection equipment in real time. Specification Hardware ● Processor: high performance intelligent processor. ● Screen: 4.3inch Touch Screen. ● Operation keys: PVE film keyboard. ● Interface: ● 3.5mm stereo headphone interface ● DC LV current charging interface ● USB 2.0 3G wireless network in...
  • China High Quality resistance of earthing system Supplier –  GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot

    China High Quality resistance of earthing system Supplier – GD3126A (GD3126B) Insulation Resistance Tester 5kV/10TΩ (10kV/20TΩ) – HV Hipot

    General Information GD3126A  (GD3126B) Insulation Resistance Tester is widely used in maintenance of electrical equipment in transformer substation, power plant, etc. It is suitable for carrying out measurement of insulation resistance (IR), absorption ratio (DAR), polarization index (PI), leakage current (Ix) and absorption capacitance (Cx) of all kinds of high voltage equipment, including switchgear, transformers, reactors, capacitors, motors, generators and cables, etc. Features ● Adopts microcomputer control, menu operation and large LCD screen dot matrix display with stable performance. ● Strong anti-interference ability, suitable for measuring in strong electromagnetic interference environment. ● Large capacity, can meet the requirements of high voltage, high resistance, lar...
  • OEM Best types of earthing test Factory –  GD2000D Insulation Resistance Tester – HV Hipot

    OEM Best types of earthing test Factory – GD2000D Insulation Resistance Tester – HV Hipot

    General Information GD2000D digital insulation resistance tester produced by our company uses an embedded industrial single chip real-time operating system. The digital analog pointer and digital field code display are perfectly combined. This series of meters has a variety of voltage output levels (250V, 500V, 1000V, 2500V, 5000V, 10000V), large capacity, strong anti-interference, analog pointer and digital synchronous display, AC and DC dual-use, simple operation, automatic calculation of various insulation indicators (absorption ratio, polarization index), various measurement results with anti-power-down function, etc. It is an ideal test instrument for measuring the insulation resistance of large-capacity transformers, transformers, generators, high-voltage motors, power capacito...

Send your message to us:

Write your message here and send it to us