  • China High Quality Cable Fault Finder Suppliers –  GD-7018A Optical Fiber Identifier – HV Hipot

    China High Quality Cable Fault Finder Suppliers – GD-7018A Optical Fiber Identifier – HV Hipot

    The GD-7018 series optical fiber pipeline identifier can accurately locate and meaure depth of the underground pipelines, cables and optical cables under the condition of without digging, and accurately find the damage points of the outer coating of the underground pipelines and the location of the underground cable fault points. The instrument incorporates the most advanced technologies such as ultra-narrow band filter, Bluetooth wireless communication, GPS positioning, automatic data mapping by professional data analysis software and automatic generation of test reports. The detection and inspection of various kinds of metal pipelines, pipeline management and maintenance, municipal planning and construction, pipeline inspection in power supply and other departments is one of the neces...
  • OEM Best Infrared Leak Detector Manufacturers –  GDJD-3A SF6 gas Density Relay Calibrator – HV Hipot

    OEM Best Infrared Leak Detector Manufacturers – GDJD-3A SF6 gas Density Relay Calibrator – HV Hipot

    Product Description GDJD-3A SF6 gas Density Relay Calibrator is automatic calibrator, which uses embedded microprocessor to proceed performance calibration for all kinds of SF6 gas density relay. It is also a portable device which can make standard conversion for SF6 gas pressure at any environmental temperature. This device is mainly used for SF6 gas products production, maintenance and monitoring in power system. Features ● Automatically calibrate density relay and pressure gauge. ● Compact design, small size, and light weight, easy to carry. ● Color LCD screen, Windows menu. ● The power supply has UPS function, suitable for field operation. ● With mini-printer, to print test result directly. ● Good sealing property, do not waste SF6 gas during calibration. ● The two ends of con...
  • China High Quality High Voltage Tester Supplier –  AC Dielectric Test Equipment with manual control unit GDYD-M – HV Hipot

    China High Quality High Voltage Tester Supplier – AC Dielectric Test Equipment with manual control unit GDYD-M – HV Hipot

    Application AC Hipot testing is the effective and direct way to test insulation strength for electric equipment, apparatus, or machines. It checks dangerous flaws which assure electric equipment continuous working. Typical applications include testing of transformers, switchgear, cables, capacitors, aerial motors platforms, hot sticks bucket bricks, vacuum bottles and other related equipment like vacuum interrupters, blankets, ropes, gloves, hydraulics hose, instruments transformers generators. Features ● Pointer display panel mounted controls & indicators with easy-to-read legend. ● Monitoring high voltage side voltage, low voltage side current and indicator of zero, power, working start, timing. ● Over-current protection, zero-starting protection, sound, and light alarm. ● C...
  • OEM Best Primary Current Injection Test Kit Manufacturers –  GDKC-15 Series Circuit Breaker Analyzer 2020.12 – HV Hipot

    OEM Best Primary Current Injection Test Kit Manufacturers – GDKC-15 Series Circuit Breaker Analyzer 2020.12 – HV Hipot

    General Information High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-15 Series is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy.  GDKC-15 Series   GDKC-15A GDKC-15B GDKC-15C GDKC-15D GDKC-15E GDKC-15F GDKC-15G GDKC-15H Metal contact 12 12 12 12 12 12 12 12 Closing resistance   6 6 6 6 6 6 6 Graphite contact       3 3 3 3 6 Double-ended grounding         3 3 3 6 Dynamic resistance(Pre-insertion resistor) 1 1 3 3   3 3 6 Static resistance 1 1 3 3   3 3 6 Ground resistance             3 6 Features ● It is suitable for the mechanical test of all types of SF6 switches, GIS combination appliances, vacuum switches and oil switches. ● Strong an...
  • China High Quality soil resistivity test Manufacturers –  Dielectric Loss Tester for Live Capacitive Equipment GDDJ-HVC  – HV Hipot

    China High Quality soil resistivity test Manufacturers – Dielectric Loss Tester for Live Capacitive Equipment GDDJ-HVC – HV Hipot

    General Information There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. If the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be found in ...
  • China High Quality Vlf Test Voltage Factories –  AC hipot test set for insulated boom GDYD-137 – HV Hipot

    China High Quality Vlf Test Voltage Factories – AC hipot test set for insulated boom GDYD-137 – HV Hipot

    Application Technical Specifications Input AC 220V± 10%, 50Hz, 32.5A, Single phase Output 0-130kV, 50mA   0-36kV, 180mA Rating 25mA/90mA, continuous working 33.3kV/120mA, 1hour ON/1hour OFF 50mA/180mA, 5mins ON/15mins OFF Capacity 6.5kVA HT Source SF6 gas (Gas testing transformer) Output control Manual control Voltage accuracy ≤ 1.5% (F.S) Current Accuracy ≤ 1.5% (F.S) Timing range  0-99H Metering LCD display, kV meter: there is a switching button, the range is 0-36kVAC if it switches to 36kV, the range is 0-130kVAC if it switches to 130kV mA meter: 0-5.000mA  Humidity 85% RH Environmental temperature -20℃~50℃
  • China High Quality electrical earthing system Exporters –  GDDT-10U Digital Grounding Down Lead Earth Continuity Tester – HV Hipot

    China High Quality electrical earthing system Exporters – GDDT-10U Digital Grounding Down Lead Earth Continuity Tester – HV Hipot

    General Information GDDT-10U Earth Continuity Resistance Tester is a highly automatic and portable test equipment. It is applied to the measurement of breakover resistance value among earth connecting cables of substation electrical equipment. The adoption of high-performance single-chip control helps to achieve intelligence of testing process. It is small size, convenient to carry, easy to operate, high-accuracy, fast testing speed, good testing repeatability, clear to read. Features ● The instrument is controlled by high-speed single chip, thus it’s highly automatic and easy to operate.  ● Using new power source technology, with many more current steps and wide measuring range. ● Intelligent power management technology, the instrument can work in the state of Min. power, w...
  • OEM Best Circuit Breaker Testing Exporters –  GDHL-100HS 100A Handheld Contact Resistance Tester  – HV Hipot

    OEM Best Circuit Breaker Testing Exporters – GDHL-100HS 100A Handheld Contact Resistance Tester – HV Hipot

    General Information The product is mainly used for the contact resistance of switch contacts and other micro-ohm resistance measurement, and the test speed is fast and the accuracy is high. This handheld contact resistance tester is an innovative product that is compact, hand-held, battery powered and easy to carry.  Features ● Maximum output current is 100A, two current levels are selectable ● Built-in large capacity lithium battery, it can perform more than 600 tests on one charge. ● The test is simple, the operation is convenient, and it can work continuously for more than 8 hours. ● In the 100A test, the longest test time can be up to 60 seconds, which can meet various usage scenarios on site. ● Wide range, high precision, up to 10mΩ at 100A. ● With complete protection functio...
  • OEM Best megger tester price Factories –  GDCR3000 Digital Earth Resistance Tester – HV Hipot

    OEM Best megger tester price Factories – GDCR3000 Digital Earth Resistance Tester – HV Hipot

    General Information GDCR3000 Digital Earth Resistance Tester is specially designed and manufactured for field measurement, adopting the latest digital and micro-processing technology, 3-pole or 2-pole method for earth resistance measurement, with a unique function of wire resistance verification, anti-interference capability and the ability to adapt to the environment, to ensure high precision, high stability and reliability for prolonged measure, which is widely used in electric power, telecommunications, meteorology, oil field, construction, lightning protection, industrial electrical equipment and other earth ground resistance measurement. Measurement range & Accuracy Measurement function Range Accuracy Resolution Earth resistance 0.01Ω~20Ω ±2%rdg ±3dgt (Auxiliary ear...
  • OEM Best Cable Route Marker Manufacturer –  GD-4136H Cable Fault Locating System  – HV Hipot

    OEM Best Cable Route Marker Manufacturer – GD-4136H Cable Fault Locating System – HV Hipot

    GD4136H Cable Fault system is an important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1.GD-2131H Impulse Generator 2.GD-4132 Cable Fault Locator 3.GD-4133 Multi-pulse Cable Fault Detector 4.GD-4133S Multi-pulse Coupler 5.Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-4133 Cable Fault Tester, there are two locating ways: a. Low vol...
  • China High Quality relay test set for sale Manufacturer –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot

    China High Quality relay test set for sale Manufacturer – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot

    Features A. Working conditions 1. Power supply: AC 220V±10%,50Hz 2. Working environment: Temperature -10℃~40℃; Humidity: ≤85% 3. Atmosphere: 86-106kPa B. Output power supply 1. AC voltage: 0-220V/3A  Adjustable 2. AC current: 0-100A/7V (200A can be customized);  0-20A/25V  Adjustable; 0-5A/5V  Adjustable 3. DC voltage: 0-220V/3A  Adjustable 4. DC current:0-20A/25V 5. Fixed voltage output: DC 24V/48V/110V/220V 6. Current/Voltage accuracy: ±1%. C. Performance Index 1. Ammeter and voltmeter: 41/2 digit. 2. Digital millisecond meter: 0-99.9999s(999.999s can be customized) Resolution: 0.1ms. D. Functions 1. Measure relay: Measure start value, return value and drop-off to pick-up ratio of current, voltage relay. 2. Time relay: Measure start value, return value and action time. 3. Intermed...
  • OEM Best Tan Delta Value Supplier –  AC Dielectric Test Equipment with manual control unit GDYD-D – HV Hipot

    OEM Best Tan Delta Value Supplier – AC Dielectric Test Equipment with manual control unit GDYD-D – HV Hipot

    Application Features ● Digital (Pointe) display panel mounted controls & indicators with easy-to-read legend. ● Monitoring high voltage side voltage, low voltage side current and indicator of zero, power, working start, timing. ● Over-current protection, zero-starting protection, sound, and light alarm. ● Continuously variable output from zero to full voltage. ● Adjustable over current protection, with trip levels variable from 10 to 110%. ● With new type time relay, time range is wider (1S ~ 99H). ● Using the latest current relay, more accurate and reliable. ● Light weight, small size, easy to move. Technical Specifications ● Input voltage: AC 220V or 380V ● Output voltage of control unit: AC 0-250V or 0-430V ● Output current of control unit:0-5/10/15/50A(customized) ● Ca...