OEM Best earth leakage current test Factories – GDDT-10U Digital Grounding Down Lead Earth Continuity Tester – HV Hipot
General Information GDDT-10U Earth Continuity Resistance Tester is a highly automatic and portable test equipment. It is applied to the measurement of breakover resistance value among earth connecting cables of substation electrical equipment. The adoption of high-performance single-chip control helps to achieve intelligence of testing process. It is small size, convenient to carry, easy to operate, high-accuracy, fast testing speed, good testing repeatability, clear to read. Features ● The instrument is controlled by high-speed single chip, thus it’s highly automatic and easy to operate. ● Using new power source technology, with many more current steps and wide measuring range. ● Intelligent power management technology, the instrument can work in the state of Min. power, w... -
China High Quality power consumption of monitor Manufacturers – GDYM-3F Portable Multi-functional Energy Meter Calibrator – HV Hipot
Features ● Synchronously calculate all parameters and display on the interface include full wave, fundamental wave and harmonic wave as the same time show U, I, P, Q, VA, phase angle about full wave and fundamental wave as well as the harmonic synthesis of I, U, P, Q, VA and its percentage, the content of U, I positive sequence, negative sequence, zero sequence and harmonics of PH+, PH-, PH+/Pf%, PH-/Pf%, full wave PF, fundamental wave PF, harmonic wave PF. ● Inspection method include 7 kinds of ways of full wave active, full wave reactive power, full wave apparent, fundamental wave active, fundamental wave reactive power, fundamental wave apparent and harmonic wave, which can check the active power accuracy of full wave meter, fundamental meter, harmonic wave meter and the reactive ... -
China High Quality Test Current Injection Supplier – GDHL-200B / GDHL-500B / GDHL-600B Contact Resistance Tester (Microhm meter) – HV Hipot
Features ● Output high-current continuously. ● Quick and accurate test. Test current is generated from high-precision 100A/200A switching mode constant current power supply, no need for manual adjustment. ● Adopts four-terminal wiring method. The influence of test line resistance on test results is effectively eliminated. ● Stable performance. There is over-heat protection crcuit designed for long-time working. ● Light weight, easy to carry and operate. Specifications GDHL-500B Contact Resistance Tester (Micro-ohm Meter) Specifications Accessories Main unit 1 set Test wire 4 pieces Power cord 1 piece Print paper 2 rolls Ground cable 1 piece User’s guide 1 copy Test Report 1 copy GDHL-600B Contact Resistance Tester (Micro-oh... -
China High Quality surge arrester tester Supplier – GDYZ-301 Zinc Oxide Surge Arrester Tester – HV Hipot
Features 1. 800*480 color LCD touch screen, with high speed thermal printer. 2. Graphic display, intuitive interface, easy to operate and use on-site. 3. Long distance wireless transmission. PT signal wireless transmission distance more than 400m (2000m can be customized). 4. Suitable for testing in various situation such as lightning arrester with or without electricity, laboratory. 5. Test three phase current, three phase voltage at the same time, more efficient. 6. No strong electricity inside, voltage not more than 12V. Current and voltage sensors are completely isolated, safe and reliable. 7. Support various voltage sampling: 1. Wired; 2 wireless; 3. Non-voltage; A. Wire: digital signal transmission with cable which the signal is from PT metering winding; B. Wireless: digital s... -
China High Quality Breaker Meter Factories – GDHL-100A Micro-Ohmmeter – HV Hipot
General Information GDHL-100A Micro-Ohmmeter is widely used to measure loop resistance and contact resistance for weld joints, cables, and various HV switches within power industry. It uses intelligent power test system “Smart-Quick”, which is granted software copyright, and advanced detection technology. Features ● Adopt high-precision constant current power supply, automatic rising current mode without manual adjustment, the test is fast and accurate. ● Use four-terminal wiring method, effectively eliminate the interference produced by test cable resistance; ● Wide range, high accuracy, the resistance measurement range is up to 99mΩ. ● Multiple test times can be set, which meets various on-site applications; ● Large current output for a long time, burning the switch ... -
China High Quality Insulator Tester Suppliers – Online Monitoring System for Metal Oxide Arrester – HV Hipot
General Information There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. As long as the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be f... -
China High Quality Transformer Capacitance Exporters – AC High Voltage Test Sets for GIS – HV Hipot
Applications ● Transformer ● GIS system ● SF6 switchgear ● Cables ● Bushing ● Insulator ● CT/PT ● Other capacitive devices Features ● Small temperature rises at rated load. Dry or Oil type reactors, high mechanical strength, good insulation, nice and reliable. ● Adjustable capacity of frequency control source. Strong protection, good stability. With multiple working mode, easy to operate. ● With 220V or 380V single phase power, convenient for on-site power sourcing. ● Flexible configuration. Different type reactors for optional, meet different test object requirements. Multifunctional, cost effective. Specifications ● Rated output voltage: based on different test objects. ● Output frequency: 20- 300Hz. ● Waveform: pure sine wave, THD <1.0%. ● Max. capacity: 1000kVA and below. ● Duty ... -
China High Quality earth resistivity Exporters – Online Monitoring System of Circulating Current on Cable Sheath GDCO-301 – HV Hipot
General Information Cables above 35kV are mainly single-core cables with metal sheath. Since the metal sheath of the single-core cable is hinged with the magnetic field line generated by the AC current in the core wire, the two ends of the single-core cable have a high induced voltage. Therefore, appropriate grounding measures should be taken to keep the induced voltage within the safe voltage range (usually no more than 50V, but no more than 100V with safety measures). Usually, the metal sheath of short line single-core cable is grounded directly at one end and grounded through gap or protection resistor at the other end. The metal sheath of long line single – core cable is grounded by three – phase segmental cross – connection. No matter which kind of grounding me... -
China High Quality withstanding voltage tester, Manufacturers – Turn-to-turn Surge Tester – HV Hipot
GDZJ-10S Turn to Turn Surge Withstand Testerh GDZJ-10S is used to test turn-to-turn insulation strength of single phase motor, 3-phase motor, Micro motor, Special motor, electrical motor, transformer (including switching mode power supply transformer), relay and winding electrical equipment. Features It can detect below faults: ● Turn-to-turn Insulation breakdown ● Corona discharge ● Winding connection mistake ● Winding disconnection ● Turn-to-turn difference ● Short-circuit between inter-phase, winding phase, or iron core Specifications ● Peak voltage: 500-10kV continuous adjustment ● Peak error: ≤ 5%(1kV-5kV) ● Waveform rising time: 0.5μS or 0.2μS ● Power supply: 220V±10%, 50Hz ● Power consumption: ≤ 800 W ● Dimension: 900*460*550mm ● Weight: about 70kg Important Tips GDZJ... -
OEM Best name the instrument used to measure the installtion resistance Factories – GDF-3000A DC System Earth Fault Detector – HV Hipot
General Information DC system insulation faults, DC mutual faults and AC power failures are faults that are prone to occur and are harmful to the power system, and endanger the normal operation of the power system. In order to better help field maintenance personnel to quickly and accurately find DC faults, our company has developed a DC fault finder by years of efforts and summing up a large number of field experiences. The DC grounding finder uses a high-precision current clamp meter to detect and locate faults using the DC current difference in the fault loop. The fast FFT transform technology is introduced into the DC fault finding device, to detect various types of insulation faults, DC mutual faults, and AC power failures in DC systems with different voltage level (24V (optiona... -
OEM Best Gas Detector System Supplier – GDPDS-341 SF6 Electrical Insulation State Comprehensive Analyzer – HV Hipot
General Information At present, the UHV voltage level of 110KV and above uses SF6 gas-insulated enclosed GIS as the main primary equipment of the substation, the evaluation of GIS internal insulation status is mainly achieved by partial discharge detection method and SF6 gas chemical analysis method at home and abroad. When partial discharge occurs in the early stage of insulation degradation inside the GIS, it will cause serious safety hazards to its safe operation. The detection methods of partial discharge mainly include three methods: ultra-high frequency partial discharge test, ultrasonic partial discharge test, and chemical detection of SF6 gas composition. At present, there are separate devices for these types of test methods on the market. For on-site GIS partial discharge li... -
OEM Best megger 1000v price Exporters – GD3128 Series Insulation Resistance Tester – HV Hipot
General Information GD3128 series Insulation Resistance Tester has perfect testing function of various insulation resistance parameters and excellent anti-interference ability, which can be used to test the insulation resistance of large capacity high voltage electrical equipment and transmission lines in strong inductive environment such as substation. The instrument adopts true color touch screen, all test data and battery power are displayed on the same screen at a glance, and the combination of knob switch and key makes the operation very simple. The user does not need to memorize the operation method. Click “HELP” on the screen to pop up the operation method, which can effectively guide the user to operate the instrument. The instrument has the function of fast disch...