OEM Best Cb Tester Manufacturers – GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot
Adoption of Standard ● DL/T 596-2005 “Procedure Test Procedures for Electrical Equipment” ● GB1094.1-GB1094.6-96 “Shell protection level” ● GB2900 “Electrical Terminology” ● GB/T16927.1~2-1997 “High Voltage Test Technology” ● GB4793-1984 “Safety Requirements for Electronic Measuring Instruments” ● GB191 “Package Storage and Transportation Mark” ● GB/T.311-1997 “Insulation and coordination of high voltage power transmission and transformation equipment” Features ● Using high conductivity copper as the output electrode, the contact surface is large and the flow capacity is strong. ● Brushed aluminum plate with a new process, simple and eye-catching, wear-resistant and pollution-resistant. ● The all-... -
China High Quality lubricant oil acid test Exporters – GDCP-510 Oil Freezing Point Tester – HV Hipot
General Information GDCP-510 Low Temperature Freezing Point Tester is compliant with GB/T 510 “Determination of Solidification Point for Petroleum Products” and GB/T 3535 ”Petroleum Products―Determination of Pour Point. “(ISO 3016) It adopts compressor refrigeration, enclosed bath, equipped with tilt bracket and automatic digital display controller, which uses fuzzy control and PID self-tuning technology, performance is more stable. Specification Temperature range Room temperature to -75ºC. Accuracy ±0.1ºC Refrigeration Germany imported sensor, cascade compressor refrigeration, with new type refrigerant, more quickly and environment friendly. Structure Two-slot & four-hole Temperature correction and display based on automati... -
China High Quality High Current Circuit Breaker Test Set Factories – GDHL-200A (GDHL-100A) Micro-Ohmmeter new – HV Hipot
General Information GDHL-200A (GDHL-100A) Micro-Ohmmeter is widely used to measure loop resistance and contact resistance for weld joints, cables, and various HV switches within power industry. It uses intelligent power test system “Smart-Quick”, which is granted software copyright, and advanced detection technology. Features ● Adopt high-precision constant current power supply, automatic rising current mode without manual adjustment, the test is fast and accurate. ● Use four-terminal wiring method, effectively eliminate the interference produced by test cable resistance. ● Wide range, high accuracy, the resistance measurement range is up to 99mΩ. ● At 200A, max. test time can reach 1~999s, which meets various on-site applications. ● Large current output for a long tim... -
China High Quality gas analysis in transformer oil Factories – GDBS-305 Automatic Flash Point Closed Cup Tester – HV Hipot
General Information GDBS-305 automatic closed cup flash point tester is the device testing closed cup flash point for petroleum products. It use module design which one host can control several testing furnace, to test different samples at the same time or separately. The testing furnace port can be connected to the host disorderly. It widely used in the field of railway, air company, power, petroleum and research department. Features ● 320*240 TFT LCD screen. ● With high speed signal processor control, reliable and high accuracy. ● One host can control several test furnace to test several samples at one time, which will save testing time. ● Automatic ignition with no gas source ignition mode. ● Built-in atmosphere pressure sensor, auto-measure and calibrate result. ● Self-adapti... -
China High Quality Ac Power Tester Manufacturer – AC Power Supply GDUP – HV Hipot
General information The GDUP-6000 (GDUP-3000) is a versatile portable pure sine wave on-site AC test power supply. Also known as on-site AC and DC test power supply, AC and DC emergency power supply, field test power supply, mobile test power supply. It has a safe power lithium-ion battery and efficient SPWM inverter conversion technology, with light weight, small size, long life and high capacity. Application Widely used in outdoor equipment such as power equipment emergency repair, power field test, mobile office, medical rescue, fire emergency rescue, environmental protection, emergency communication support, and power storage backup. It also provides a safe and reliable power source for instruments in the laboratory or in the field. Main Application 1. 220V/50Hz pure sine w... -
China High Quality surge arrester tester Supplier – GD-610B Insulator Faults Detector – HV Hipot
General Information In High Voltage Distribution Network, it usually cause the faults of flashover, grounding or porcelain explosion because of insulators degradation. So it is important to detect and eliminate the faults of insulators, to ensure safe running of transmission and distribution line. GD-610B Insulator Faults Detector is used to locate insulator faults in power plants and substation transmission lines under uninterrupted power state. It can also be used in partial discharge detection of electrical equipment, corona discharge detection, high voltage switch discharge detection and so on. Applications The electric power, agricultural power, water conservancy and other departments in all regions that have power transmission lines, as well as scientific research units of i... -
China High Quality Cap Coupling Manufacturer – VLF AC Hipot Test Set 80kV – HV Hipot
Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. AC test can be further divided into power frequency, variable frequency and 0.1Hz very low frequency test, among which the last one is highly recommended by IEC, due to its remarkable advantages. Following is a comparison for DC, Power Frequency, Variable Frequency, and 0.1Hz test. Aspects DC Power Frequency Variable Frequency 0.1Hz Equivalency poor good good good Insulation Damage strong slight slight slight Operation Safety relatively low relatively low relatively low high Wiring Difficulty complicated complicated most complicated simple Volume smallest largest large smal... -
China High Quality clamp meter price Factory – GD2000H 10kV Insulation Resistance Tester – HV Hipot
General Information This device can test insulation resistance (such as transformer, switchgear, leads, motor) of different modules in one system, to insulate and repair failure components. It is important to ensure products quality and security of person and equipment during operation by insulation test of checking test object to ground or adjacent conductors’ insulation. Before power on the system, use insulation test to verify if it is good to improve system performance. Insulation test is to find manufacturing process problems and equipment fault which can’t be found before failure happened. In EU, this test is compulsory, even to civil system. Features 1. Voltage output GD2000H (5kV/10kV).Resistance range 0-400GΩ. 2. Two modes display insulation resistance. 3. Aut... -
OEM Best Circuit Breaker Test Equipment Exporters – GDSL-D Seriese Digital Primary Current Injection Test Set – HV Hipot
Adoption of Standard ● DL/T 596-2005 “Procedure Test Procedures for Electrical Equipment” ● GB1094.1-GB1094.6-96 “Shell protection level” ● GB2900 “Electrical Terminology” ● GB/T16927.1~2-1997 “High Voltage Test Technology” ● GB4793-1984 “Safety Requirements for Electronic Measuring Instruments” ● GB191 “Package Storage and Transportation Mark” ● GB/T.311-1997 “Insulation and coordination of high voltage power transmission and transformation equipment” Features ● Using high conductivity copper as the output electrode, the contact surface is large and the flow capacity is strong. ● Brushed aluminum plate with a new process, simple and eye-catching, wear-resistant and pollution-resistant. ● The all-... -
China High Quality Ct/Pt Tester Factories – GDHG-108A CT/PT Tester – HV Hipot
GDHG-108A CT/PT Tester supports test voltage method to test bushings CTs which installed on transformer or inside switch-gear, suitable for the laboratory and on-site detection. Itcan be easily and conveniently done voltage current characteristic, transformer ratio, ratio and phase angle error, load test items on CT/PT. Features ● Using the voltage detection principle to measure CT and PT. ● To meet the requirements of GB1207, GB1208, GB168-47 (IEC60044-1.6) and other standards. ● No external auxiliary equipment, a single machine can complete all test items. ● With high speed micro printer: real-time print the test result. ● Using intelligent controller, operation is simple. ● 5inch LCD screen display. ● Automatically given CT/PT (excitation) knee point value. ● Auto display 5% and 1... -
China High Quality Caple And Pipe Locators Suppliers – GD-4136H Cable Fault Locating System – HV Hipot
GD4136H Cable Fault system is an important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1.GD-2131H Impulse Generator 2.GD-4132 Cable Fault Locator 3.GD-4133 Multi-pulse Cable Fault Detector 4.GD-4133S Multi-pulse Coupler 5.Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-4133 Cable Fault Tester, there are two locating ways: a. Low vol... -
China High Quality tension meter price Manufacturer – GDZL-503 Automatic Interfacial Tension tester – HV Hipot
Intermolecular forces will generate interface tension and surface tension of liquids. The value of tension reflects liquid sample’s physics and chemical properties, which is one of the most important index for product quality. GDZL-503 automatic interfacial tension tester tests kinds of liquid surface tension and interface tension according to ring method which is simple and accurate. It is widely used in electric, petroleum, chemical,medicine, food and teaching filed. Features ● Exclusive and quick response electromagnetic balance sensor is adopted, to improve the accuracy of the measurement and degree of linearity. ● Only using one point calibration, to solve the problem of previous sensor which needs multi-point calibration. It is no need to use zero potentiometer and full s...