  • China High Quality Gas Detection Equipment Factory –  GDP-8000CM SF6 Gas Dew Point Tester (Chilled Mirror Method)  – HV Hipot

    China High Quality Gas Detection Equipment Factory – GDP-8000CM SF6 Gas Dew Point Tester (Chilled Mirror Method) – HV Hipot

    General Information GDP-8000CM Portable Chilled Mirror SF6 Gas Dew Point Tester is specially designed for SF6 gas micro moisture detection used in the whole temperature zone of the power industry, which is based on Stryn refrigeration and chilled mirror measuring principle. It not only solved the problem that Peltier’s refrigeration principle mirror surface dew point tester could not be used in the high temperature field, but also solved the problem that the test data of the resistive and capacitive moisture meter can not be stable, the test speed is slow, and the measurement data is inaccurate. The moisture content of SF6 gas can be detected at a temperature of less than 60ºC in the environment with the accuracy of dew point ±0.2ºC. This product has fast test speed, stable per...
  • OEM Best Capacitor Checking Meter Supplier –  DC Hipot Test Set GDZG-S – HV Hipot

    OEM Best Capacitor Checking Meter Supplier – DC Hipot Test Set GDZG-S – HV Hipot

    Features ● Electronic control and tune, easy to operate. ● The date of voltage and current are recorded in the panel, reading without conversion. ● One minute timing and tip function. ● Perfect overvoltage and over-current protection function inside, also zinc oxide overvoltage protection outside, which ensure safety of generator. ● Both control unit and doubler packed with special shockproof aluminum alloy cabinet, easy to move. ● Portable design, suitable for on-site testing. Specifications Items(kV/mA) parameter 50/100 50/120 60/150 60/200 60/300 Output voltage(kV) 50 50 60 60 60 Output current(mA) 100 120 150 200 300 Output power(W) 5000 6000 9000 12000 18000 Voltage measurement error ≤1.0% ±1digit Current measu...
  • China High Quality Sf6 Purification Suppliers –  GDJD-3A SF6 gas Density Relay Calibrator – HV Hipot

    China High Quality Sf6 Purification Suppliers – GDJD-3A SF6 gas Density Relay Calibrator – HV Hipot

    Product Description GDJD-3A SF6 gas Density Relay Calibrator is automatic calibrator, which uses embedded microprocessor to proceed performance calibration for all kinds of SF6 gas density relay. It is also a portable device which can make standard conversion for SF6 gas pressure at any environmental temperature. This device is mainly used for SF6 gas products production, maintenance and monitoring in power system. Features ● Automatically calibrate density relay and pressure gauge. ● Compact design, small size, and light weight, easy to carry. ● Color LCD screen, Windows menu. ● The power supply has UPS function, suitable for field operation. ● With mini-printer, to print test result directly. ● Good sealing property, do not waste SF6 gas during calibration. ● The two ends of con...
  • China High Quality partial discharge detector Manufacturer –  Partial Discharge Online Monitoring System of Generators – HV Hipot

    China High Quality partial discharge detector Manufacturer – Partial Discharge Online Monitoring System of Generators – HV Hipot

    General Information Generally, partial discharge occurs at a position where the properties of the dielectric material are not uniform. At these locations, the local electric field strength is enhanced, and local electric field strength is too large, resulting in local breakdown. This partial breakdown is not the total breakdown of the insulating structure. Partial discharges typically require a certain amount of gas space to develop, such as gas voids inside the insulation, adjacent conductors, or insulating interfaces. When the local field strength exceeds the dielectric strength of the insulating material, a partial discharge occurs, causing many partial discharge pulses to occur during one cycle of applying the voltage. The amount of discharge delivered is closely related to the n...
  • OEM Best High Voltage Impulse Generator Supplier –  GDCL-10kA Impulse Current Generator – HV Hipot

    OEM Best High Voltage Impulse Generator Supplier – GDCL-10kA Impulse Current Generator – HV Hipot

    Working Environment ● Environmental temperature: -10℃ to 40℃ ● Related humidity: ≤ 85% RH ● Altitude: ≤ 1000m ● Indoor use ● No conductive dust, no fire or explosive danger, no corrosive metal or insulation gas. ● Power voltage waveform is sine wave, distortion rate <5% ● Earth resistance is no more than 1Ω. Applied Standard IEC60099-4: 2014 Surge Arresters-Part 4: Metal-oxide surge arresters without gaps for a.c. systems. GB311.1-1997 Insulation coordination of HV Power transmission and transformation. IEC 60060-1 High Voltage Testing Technique- General Testing Requirement. IEC 60060-2 High Voltage Testing Technique- Measurement System. GB/T16896.1-1997 Digital Recorder of High Voltage Impulse Test. DLT992-2006 Implementing Rules for Impulse Voltage Measurement. DL/T613-1997 T...
  • OEM Best Lightning Arrester Suppliers –  GDYZ-301 Zinc Oxide Surge Arrester Tester  – HV Hipot

    OEM Best Lightning Arrester Suppliers – GDYZ-301 Zinc Oxide Surge Arrester Tester – HV Hipot

    Features 1. 800*480 color LCD touch screen, with high speed thermal printer. 2. Graphic display, intuitive interface, easy to operate and use on-site. 3. Long distance wireless transmission. PT signal wireless transmission distance more than 400m (2000m can be customized). 4. Suitable for testing in various situation such as lightning arrester with or without electricity, laboratory. 5. Test three phase current, three phase voltage at the same time, more efficient. 6. No strong electricity inside, voltage not more than 12V. Current and voltage sensors are completely isolated, safe and reliable. 7. Support various voltage sampling: 1. Wired; 2 wireless; 3. Non-voltage; A. Wire: digital signal transmission with cable which the signal is from PT metering winding; B. Wireless: digital s...
  • China High Quality low cost insulation tester Suppliers –  GDCR3200C Double Clamp Multifunctional Earth Resistance Tester – HV Hipot

    China High Quality low cost insulation tester Suppliers – GDCR3200C Double Clamp Multifunctional Earth Resistance Tester – HV Hipot

    General Information GDCR3200C Double Clamp Multifunctional Earth Resistance Tester is specially designed and manufactured for on-site measurement of grounding resistance, soil resistivity, grounding voltage, grounding line leakage current, AC current and DC resistance. The instrument adopts advanced digital processing technology, with 2-wire method, 3-wire method, 4-wire method, selection method, double clamp method and other measurement methods; Import FFT (Fast Fourier Transform) technology, AFC (Automatic Frequency Control) technology, with unique anti-interference ability and environmental adaptability, high repeated test consistency, ensuring high precision, high stability and high reliability for long-term measurement.The instrument used large caliber current clamp design, can ...
  • OEM Best Timing Test Of Circuit Breaker Factory –  GDKC-15 Series Circuit Breaker Analyzer – HV Hipot

    OEM Best Timing Test Of Circuit Breaker Factory – GDKC-15 Series Circuit Breaker Analyzer – HV Hipot

    General Information High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-15 Series is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy. GDKC-15 Series GDKC-15A GDKC-15B GDKC-15C GDKC-15D GDKC-15E GDKC-15F GDKC-15G GDKC-15H Metal contact 12 12 12 12 12 12 12 12 Closing resistance 6 6 6 6 6 6 6 Graphite contact 3 3 3 3 6 Double-ended grounding 3 3 3 6 Dynamic resistance(Pre-insertion resistor) 1 1 3 3 3 3 6 Static resistance 1 1 3 3 3 3 6 Ground resistance 3 6 Features ● It is suitable for the mechanical test of all types of SF6 switches, GIS combination appliances, vacuum switches and oil switches. ● Strong anti-interference ability. It ...
  • OEM Best over under voltage protector Manufacturer –  GDYZ-302 Wireless Zinc Oxide Surge Arrester Tester – HV Hipot

    OEM Best over under voltage protector Manufacturer – GDYZ-302 Wireless Zinc Oxide Surge Arrester Tester – HV Hipot

    Product Description GDYZ-302 Zinc Oxide Arrester Live Tester is a special instrument used to test the electrical performance of Zinc Oxide Arrester. It is suitable for live or power-off detection of Zinc Oxide Arrester of various voltage levels, so that to found dangerous defects such as dampness of internal insulation and aging of valve plates in time. The instrument is simple to operate and easy to use. The entire measurement process is controlled by an industrial computer. It can measure the full current, resistive current and its harmonics, power frequency reference voltage and harmonics, active power and phase difference. Displays true waveforms of voltage and current. The instrument uses digital waveform analysis technology and software anti-interference methods such as harmoni...
  • China High Quality Resistance tester price Exporters –  GD3127 Series High Voltage Insulation Resistance Tester   – HV Hipot

    China High Quality Resistance tester price Exporters – GD3127 Series High Voltage Insulation Resistance Tester – HV Hipot

    General Information GD3127 Series Insulation Resistance Tester is widely used in maintenance of electrical equipment in transformer substation, power plant, etc. It is suitable for carrying out measurement of insulation resistance(IR), polarization index(PI), absorption ratio (DAR), ramp(RAMP), filter(FR, 10s, 20s, 30s, 40s 4 choices), voltage(V), current(nA) of all kinds of high voltage equipment, including switchgear, transformers, reactors, capacitors, motors, generators and cables, etc. GD3127 Series is the perfect test tool for early identification and discovery of preventive or predictive maintenance plans for potential equipment failures. It is of great significance to ensure product quality and the safety of people and equipment in operation. The insulation performance of ele...
  • OEM Best lightning protection installation Factories –  Online Monitoring System for Metal Oxide Arrester – HV Hipot

    OEM Best lightning protection installation Factories – Online Monitoring System for Metal Oxide Arrester – HV Hipot

    General Information There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. As long as the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be f...
  • China High Quality ultrasonic test equipment Manufacturers –  GDYZ-301A Zinc Oxide Surge Arrester Tester – HV Hipot

    China High Quality ultrasonic test equipment Manufacturers – GDYZ-301A Zinc Oxide Surge Arrester Tester – HV Hipot

    It is the special equipment of testing zinc oxide electric performance. The instrument can accurately and stably measure the arrester resistive current and the monitor counter action parameters while the equipment is running. It can also check the monitor ammeter.  Features ● 8inch color LCD touch screen, high speed thermal printer. ● The measurement data of wire and wireless is the same. ● Wireless sampling, with long distance. A. Wired: indoor use, or on-site where the PT sampling wiring cabinet is near with tested lightning arrester. B. Wireless: outdoor use, or on-site where the PT sampling wiring cabinet is far from tested lightning arrester, wireless distance is up to 1000M. ● Three-phase can be measured at the same time. The resistive current of 3channels can be measured at ...