Featured

  • China High Quality megger ground resistance tester Suppliers –  Dielectric Loss Tester for Live Capacitive Equipment GDDJ-HVC  – HV Hipot

    China High Quality megger ground resistance tester Suppliers – Dielectric Loss Tester for Live Capacitive Equipment GDDJ-HVC – HV Hipot

    General Information There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. If the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be found in ...
  • China High Quality partial voltage Exporters –  GDJF-2007 Digital Partial Discharge Analyzer – HV Hipot

    China High Quality partial voltage Exporters – GDJF-2007 Digital Partial Discharge Analyzer – HV Hipot

    Picture only for reference first. GDJF-2007 Digital Partial Discharge Analyzer is widely used for detecting partial discharge of high voltage equipment such as power transformers, instrument transformer, HV circuit breaker, GIS, Zinc oxide surge arrester, power cable. It also can make type tests and monitor insulation operation. It includes main unit, PD software, current transformer, input unit, calibration pulse generator, input adapter, antenna amplifier and connection cable etc. Features ● 12inch LCD display, with portable design, rugged and durable, easy to use. ● Strong anti-interference ability, accurate. Using digital filtering technology, field interference can be effectively eliminated, and partial discharge measurement can be realized in a strong interference environmen...
  • OEM Best Cable Testing Methods Manufacturers –  GD-2136H Cable Fault Locating System – HV Hipot

    OEM Best Cable Testing Methods Manufacturers – GD-2136H Cable Fault Locating System – HV Hipot

    GD2136H Cable Fault system is important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1. GD-2131H Impulse Generator 2. GD-2132 Cable Fault Locator 3. GD-2133 Cable Fault Tester 4. Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-2133 Cable Fault Tester, there are two locating ways: a. Low voltage pulse: If only using GD-2133, open circ...
  • OEM Best earth resistivity Manufacturer –  Substation Temperature Monitoring System – HV Hipot

    OEM Best earth resistivity Manufacturer – Substation Temperature Monitoring System – HV Hipot

    General Information There are usually two ways to monitor the insulation condition of high voltage electrical equipment in substations: online monitoring and live (portable) online detection. The former one can obtain the characteristic parameters reflecting the abnormal insulation of the equipment at any time, which is convenient for automatic management. However, the investment is relatively large, the installation and construction are relatively troublesome, and regular maintenance is needed. For the latter, it has the advantages of low investment, highly targeted, easy to install, maintain and update. As long as the sampling unit is installed in the electrical equipment in advance, a regular detection can be done for electrical equipment in operation, and insulation flaw can be f...
  • China High Quality Vlf High Voltage Testing Manufacturers –  AC DC High Voltage Divider – HV Hipot

    China High Quality Vlf High Voltage Testing Manufacturers – AC DC High Voltage Divider – HV Hipot

    GDFR-C1 series AC/DC Voltage Meter GDFR-C1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. It consists of voltage divider and measurement instrument. Features ● Balance type equal potential shield structure. ● Fully-sealed insulation cylinder with internal excellent components. ● High accuracy and linearity, good stability and anti-interference ability. ● The voltage ratio can be customized, suitable for calibration. ● Upside down is forbidden when installation. Technical Specifications Model No. GDFR-C1-50 GDFR-C1-100 GDFR-C1-150 GDFR-C1-200 GDFR-C1-300 GDFR-C1-400 Voltage(kV) 50 100 150 200 300 400 DC frequency (Hz) <2 AC frequency (Hz) 30-300 Accuracy AC: 1.5%/DC: 1.0% Accuracy for option (G type) AC: 1.0%/DC: 0.5% – Accura...
  • China High Quality apa itu partial discharge Manufacturers –  GDJF-2006 Partial Discharge Analyzer – HV Hipot

    China High Quality apa itu partial discharge Manufacturers – GDJF-2006 Partial Discharge Analyzer – HV Hipot

    Features ● With high speed, big capacity data acquisition card. Continuously collect partial discharge data, good repeatability, and high accuracy. ● Functions of testing, analyzing (multi-parameter analysis, two-dimension atlas analysis, three-dimension atlas analysis), data storage, report, and print. Display waveform (ellipse, sine wave, line), discharge value and test voltage. ● Suitable for 50Hz, 150Hz frequency power supply, up to 400Hz. Automatic tracking external power supply frequency. ● Big color LCD screen. Large memory, with USB port. ● With anti-false operation function. Automatic adjusting gain during testing and rectifying. ● Anti-interference design. Specifications ● Capacitance range: 6pF-250μF ● Sensitivity: <0.02pc (capacitance at 50pF)                   ● Am...
  • China High Quality closed cup flash point tester Manufacturer –   GDSZ-402 Automatic Acid Value Tester – HV Hipot

    China High Quality closed cup flash point tester Manufacturer – GDSZ-402 Automatic Acid Value Tester – HV Hipot

    General Information  Automatic Acid Value Tester is designed for testing acid value for transformer oil, turbine oil and fire resistant oil etc. PC control system can improve the work efficiency and reduce the harm in organic solvents and chemicals to human body. This instrument is easy to operate and have good capacity in anti-interference and stability.  Features ● 320*240 LCD touch screen, user-friendly interface. ● Neutralization titration principle, to complete liquid charge, titrate, stir, determine the titration end point automatically under normal temperature. LCD screen can show the test result and print. ● Color sensor can match up the test titration end point, the judgment of end condition is reliable. ● Waste liquor cup is no need. ● Peristaltic pump control the cha...
  • China High Quality closed cup test Suppliers –  GDC-9560B Power System Insulation Oil Gas Chromatograph Analyzer – HV Hipot

    China High Quality closed cup test Suppliers – GDC-9560B Power System Insulation Oil Gas Chromatograph Analyzer – HV Hipot

    General Information  GDC-9560B Gas Chromatograph Analyzer is to analyze the gas content of insulation oil by gas chromatographic method. It is effective to judge if the running equipment has potential fault like over-heat, discharge or not, to ensure the safety of power grid. It is also necessary to be used for manufacturer of gas/oil equipment to inspect their equipment before leaving factory. Gas chromatography analysis technology is a technique for separation and analysis of multi-component mixtures. It mainly uses the difference of boiling point, polarity and adsorption coefficient of each component in the sample in the column, so that the components are separated in the column, and the separated components are qualitatively and quantitatively analyzed. The gas chromatograph uses...
  • OEM Best Simulate Lightning Impulse Factories –  GDCL-V 20kV/10kA Impulse Combination Wave Test System Technical Solution – HV Hipot

    OEM Best Simulate Lightning Impulse Factories – GDCL-V 20kV/10kA Impulse Combination Wave Test System Technical Solution – HV Hipot

    Application The equipment is according to combination wave testing requirement of the low-voltage power distribution system SPD II product, enable to generate impulse voltage (1.2/50μs) and impulse current (8/20μs), is used for grade III test and limiting voltage test of SPD and components. It is also used for impulse current test and residual voltage test of the MOV valve plate, unit and surge protective device(SPD), or used in other scientific research experiments. The device uses touch screen and PLC control technology, and the main performance meets the needs of domestic and foreign SPD products and their components for various combination wave testing. Standards ● GB 18802.1-2012 GB 18802.1-2012 Surge protective devices connected to low-voltage power distribution systems Part 1:Req...
  • China High Quality High Voltage Vlf Hipot Instruments Exporters –  Insulation Materials Hipot Test Set GDJS-65 – HV Hipot

    China High Quality High Voltage Vlf Hipot Instruments Exporters – Insulation Materials Hipot Test Set GDJS-65 – HV Hipot

    GDJS-65 Insulation Gloves Test Set It is used to test insulation performance for insulation gloves, boots, mats, hats, rod, Electroscope etc. It can test 6pcs insulation gloves/boots at the same time, also 5pcs insulation rods. Features Manual control unit ● Digital and real time display HV voltage, LV current, 6-way leak current and time. ● With leak current meter and over-current protection meter. ● With movable control unit, easy wiring and testing. ● Manual control, safety and reliability. ● With zero, power, operation, timing indicators. ● With over-current protection, zero-start protection, sound and light alarm, power protected switch. ● New type timer, broader timing range.(1s-99h). Other features ● HV source is oil immersed type testing transformer.(dry type and SF6 gas t...
  • China High Quality 5kv insulation tester Manufacturers –  GD2000H 10kV Insulation Resistance Tester – HV Hipot

    China High Quality 5kv insulation tester Manufacturers – GD2000H 10kV Insulation Resistance Tester – HV Hipot

    General Information This device can test insulation resistance (such as transformer, switchgear, leads, motor) of different modules in one system, to insulate and repair failure components. It is important to ensure products quality and security of person and equipment during operation by insulation test of checking test object to ground or adjacent conductors’ insulation. Before power on the system, use insulation test to verify if it is good to improve system performance. Insulation test is to find manufacturing process problems and equipment fault which can’t be found before failure happened. In EU, this test is compulsory, even to civil system. Features 1. Voltage output GD2000H (5kV/10kV).Resistance range 0-400GΩ. 2. Two modes display insulation resistance. 3. Aut...
  • China High Quality Power Factor Capacitor Suppliers –  AC DC High Voltage Divider – HV Hipot

    China High Quality Power Factor Capacitor Suppliers – AC DC High Voltage Divider – HV Hipot

    GDFR-C1 series AC/DC Voltage Meter GDFR-C1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. It consists of voltage divider and measurement instrument. Features ● Balance type equal potential shield structure. ● Fully-sealed insulation cylinder with internal excellent components. ● High accuracy and linearity, good stability and anti-interference ability. ● The voltage ratio can be customized, suitable for calibration. ● Upside down is forbidden when installation. Technical Specifications Model No. GDFR-C1-50 GDFR-C1-100 GDFR-C1-150 GDFR-C1-200 GDFR-C1-300 GDFR-C1-400 Voltage(kV) 50 100 150 200 300 400 DC frequency (Hz) <2 AC frequency (Hz) 30-300 Accuracy AC: 1.5%/DC: 1.0% Accuracy for option (G type) AC: 1.0%/DC: 0.5% – Accura...