OEM Best Primary Current Injection Test Set Price Manufacturer – GDHL-200B / GDHL-500B / GDHL-600B Contact Resistance Tester (Microhm meter) – HV Hipot
Features ● Output high-current continuously. ● Quick and accurate test. Test current is generated from high-precision 100A/200A switching mode constant current power supply, no need for manual adjustment. ● Adopts four-terminal wiring method. The influence of test line resistance on test results is effectively eliminated. ● Stable performance. There is over-heat protection crcuit designed for long-time working. ● Light weight, easy to carry and operate. Specifications GDHL-500B Contact Resistance Tester (Micro-ohm Meter) Specifications Accessories Main unit 1 set Test wire 4 pieces Power cord 1 piece Print paper 2 rolls Ground cable 1 piece User’s guide 1 copy Test Report 1 copy GDHL-600B Contact Resistance Tester (Micro-oh... -
OEM Best High Voltage Divdier Factory – VLF AC Hipot Test Set – HV Hipot
Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. AC test can be further divided into power frequency, variable frequency and 0.1Hz very low frequency test, among which the last one is highly recommended by IEC, due to its remarkable advantages. Following is a comparison for DC, Power Frequency, Variable Frequency, and 0.1Hz test. Aspects DC Power Frequency Variable Frequency 0.1Hz Equivalency poor good good good Insulation Damage strong slight slight slight Operation Safety relatively low relatively low relatively low high Wiring Difficulty complicated complicated most complicated simple Volume smallest largest large smal... -
OEM Best Capacitance Setting Multimeter Factory – AC DC High Voltage Divider – HV Hipot
GDFR-C1 series AC/DC Voltage Meter GDFR-C1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. It consists of voltage divider and measurement instrument. Features ● Balance type equal potential shield structure. ● Fully-sealed insulation cylinder with internal excellent components. ● High accuracy and linearity, good stability and anti-interference ability. ● The voltage ratio can be customized, suitable for calibration. ● Upside down is forbidden when installation. Technical Specifications Model No. GDFR-C1-50 GDFR-C1-100 GDFR-C1-150 GDFR-C1-200 GDFR-C1-300 GDFR-C1-400 Voltage(kV) 50 100 150 200 300 400 DC frequency (Hz) <2 AC frequency (Hz) 30-300 Accuracy AC: 1.5%/DC: 1.0% Accuracy for option (G type) AC: 1.0%/DC: 0.5% – Accura... -
OEM Best ac withstand test, Manufacturers – Turn-to-turn Surge Tester – HV Hipot
GDZJ-10S Turn to Turn Surge Withstand Testerh GDZJ-10S is used to test turn-to-turn insulation strength of single phase motor, 3-phase motor, Micro motor, Special motor, electrical motor, transformer (including switching mode power supply transformer), relay and winding electrical equipment. Features It can detect below faults: ● Turn-to-turn Insulation breakdown ● Corona discharge ● Winding connection mistake ● Winding disconnection ● Turn-to-turn difference ● Short-circuit between inter-phase, winding phase, or iron core Specifications ● Peak voltage: 500-10kV continuous adjustment ● Peak error: ≤ 5%(1kV-5kV) ● Waveform rising time: 0.5μS or 0.2μS ● Power supply: 220V±10%, 50Hz ● Power consumption: ≤ 800 W ● Dimension: 900*460*550mm ● Weight: about 70kg Important Tips GDZJ... -
China High Quality relay tester kit Manufacturers – GDJR-200D Single Phase Electronic Thermal Relay Calibrator – HV Hipot
Standard compliance GB/T 14598.15-1998 Electric Relays Part 8: Thermal Electrical Relays DL/T 624-1997 Technical Specification of Test Equipment Based on Micro-computer for Relaying Protection DL/T 846-2004 General Technical Specifications for High Voltage Test Equipments DL/T 596-2005 Preventive Test Code for Electric Power Equipment GB50150-2006 Electrical Equipment Installation Engineering-standard for Hand-over Test of Electric Equipment GB1094.1-GB1094.6-96 Degrees of Protection Provided by Enclosure (IP Code) GB2900 Electro-technical terminology GB/T16927.1~2-1997 High Voltage Test Techniques GB4793-1984 Safety Requirements for Electronic Measuring Apparatus GB191 Packaging-Pictorial Marking for Handling of Goods GB/T.311-1997 Insulation co-ordination for... -
OEM Best Gas Leak Detection Methods Exporters – GDQC-16A(mini) SF6 Vacuum Pumping and Filling Device – HV Hipot
General Information GDQC-16A Gas Vacuum Pumping and Filling Device is mainly used as auxiliary equipment of gas equipment GCBT, GIS, SF6 during installing, debugging and repairing in various power supply companies, power transmission engineering companies, power plants, ultra high voltage transmission, SF6 gas electrical switch manufacturing plant and other departments. It can perform to pump vacuum and fill gas for electric equipment. Features ● Can be moved as a tanker with an armored hose ● Pointer type vacuum display. ● Weighing function. (optional) ● Storage tank heating function. (optional) ● Multi protection-function can ensure safe operation. ● Easy maintenance and high performance. ● Suitable for 10-35kV electrical devices. Technical Specifications Vacuum Pump Ra... -
China High Quality Capacitor Tester Price Factories – Insulation Materials Hipot Test Set GDJS-65 – HV Hipot
GDJS-65 Insulation Gloves Test Set It is used to test insulation performance for insulation gloves, boots, mats, hats, rod, Electroscope etc. It can test 6pcs insulation gloves/boots at the same time, also 5pcs insulation rods. Features Manual control unit ● Digital and real time display HV voltage, LV current, 6-way leak current and time. ● With leak current meter and over-current protection meter. ● With movable control unit, easy wiring and testing. ● Manual control, safety and reliability. ● With zero, power, operation, timing indicators. ● With over-current protection, zero-start protection, sound and light alarm, power protected switch. ● New type timer, broader timing range.(1s-99h). Other features ● HV source is oil immersed type testing transformer.(dry type and SF6 gas t... -
OEM Best open cup flash point test Supplier – Transformer Oil Gas Chromatography Online Monitoring System – HV Hipot
General Information GDDJ-DGA Transformer Oil Gas Analyzer is an online monitoring device for dissolved gas in transformer oil based on gas chromatography technology. Potential fault are determined, release alert as per preset value through expert diagnosis system. The device adopts distributed control sampling technology and has self-diagnosis and self-recovery functions. Each function module is weak coupling, function independent, adopting rack structure, easy for engineering maintenance. Features ● Maintenance-free, no need to replace gas cylinder. ● On-line detection the concentration and growth rate of H2, CO, CO2, CH4, C2H4, C2H2, C2H6. ● Modular design and compact structure, easy for maintenance, with high expansibility, can be easily integrated to other monitoring equipmen... -
China High Quality to test earth resistance Supplier – GD3127 Series High Voltage Insulation Resistance Tester – HV Hipot
General Information GD3127 Series Insulation Resistance Tester is widely used in maintenance of electrical equipment in transformer substation, power plant, etc. It is suitable for carrying out measurement of insulation resistance(IR), polarization index(PI), absorption ratio (DAR), ramp(RAMP), filter(FR, 10s, 20s, 30s, 40s 4 choices), voltage(V), current(nA) of all kinds of high voltage equipment, including switchgear, transformers, reactors, capacitors, motors, generators and cables, etc. GD3127 Series is the perfect test tool for early identification and discovery of preventive or predictive maintenance plans for potential equipment failures. It is of great significance to ensure product quality and the safety of people and equipment in operation. The insulation performance of ele... -
OEM Best Ct And Pt Supplier – GDHG-201P CT/PT Analyzer – HV Hipot
Features ● Full function and can satisfy all kinds of CT (protection CT, measuring CT, TP) test requirements, such as excitation characteristic test, turn ratio, polarity, secondary winding resistance, secondary burden, ratio error, angular difference and etc. Also can used to test excitation characteristic, turn ratio, polarity, secondary winding resistance, ratio error, angular difference and etc of all kinds of PT. ● Field verification of CT does not require standard current transformers, current injector, load bank, voltage regulating controller and large current cables. Very simple test wiring and operation are used to realize the current transformer verification, which greatly reduces the work intensity and improves the work efficiency, and facilitates the field verification of... -
China High Quality Capacitance Effect Factory – 30kVA.200kV Automatic AC.DC Hipot Test Set GDYD-2030A – HV Hipot
Features ● 7inch color LCD screen, with PLC automation control. ● HV Voltage, LV voltage, LC current measured at the same time, with high precision sensor and high-performance collection chip. ● Automatic mode and manual mode for option. ● Display HV voltage, LV voltage, LV current, time, and withstanding result. ● Over-voltage and over-current protection. Output voltage, HV current upper limit, LV current upper limit and timing can be set. ● Zero-starting function. Test can be proceeded after the voltage is back to zero. ● Store up to 8000pcs data in 3months. It has USB port to upload data to USB disk. ● When setting voltage is arrived, it will be timing automatically. After timing, voltage will be back to zero. ● When the LV current is over setting value, the voltage will be cut of... -
OEM Best Curent Tranformer Exporters – GDHG-106B CT/PT Analyzer – HV Hipot
Features ● Finish all testing items by itself, no need to connect auxiliary equipment. ● Intelligent controller is adopted. ● Built-in printer, to print results easily. ● Large screen LCD, graphically display. ● Auto display excitation knee point value, 5% and 10% error curve. ● Save 3000 groups data and it is not lost after power down. ● With USB port. The data can be saved in USB disk and read by PC (WORD format file). ● Portable design, suitable for on-site test. ● Engineering plastic box with damping, strong and reliable. Specifications Main functions CT (protection type, metering type) PT Voltage current characteristic curve (excitation characteristic) Voltage current characteristic curve (excitation characteristic) Auto calculate knee point value Auto calculate knee p...