OEM Best flash point analysis Exporters – GDND-800 Freezing Point Tester – HV Hipot
General Information 1. Transformer oil freezing point tester has the characteristics of exquisite structural design and unique manufacturing process. It conforms to GB/T 3535 and GB/T510 standards and is used to determine the pour point of petroleum products. 2. This instrument adopts compressor refrigeration technology to save energy, simple operation and long service life. Its main technical indicators such as cooling rate and cooling capacity have surpassed similar foreign products. Working conditions 1. The instrument should be placed on a flat and stable workbench, and air convection should be minimized in the environment. 2. This product may involve flammable materials when used. It is not allowed to have an open flame (or a device that produces spark) close to it during op... -
China High Quality Advantages Of Current Injection Test Factory – GDKC-12A (GDKC-12B) (GDKC-13A) Circuit Breaker Analyzer – HV Hipot
General Information High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-12A/B (GDKC-13A) is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy. Features ● Time: the open/close time, in phase synchronization, phase-to-phase synchronization of 12contacts. ● Closing resistor: pre-switching time, pre-switching waveform and resistance of the closing resistor of 6 channels. ● Reclosure: close-open, open-close, open-close-open time for each contact. ● Bounce: close bounce time, times, process and waveform of each contacts. ● Velocity: velocity at contact open or close, maximum speed, time-travel characteristic curve; first open, first close and second open velocity of reclosure. ●... -
OEM Best How To Test Circuit Breaker Factory – GDKC-15 Series Circuit Breaker Analyzer – HV Hipot
General Information High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-15 Series is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy. GDKC-15 Series GDKC-15A GDKC-15B GDKC-15C GDKC-15D GDKC-15E GDKC-15F GDKC-15G GDKC-15H Metal contact 12 12 12 12 12 12 12 12 Closing resistance 6 6 6 6 6 6 6 Graphite contact 3 3 3 3 6 Double-ended grounding 3 3 3 6 Dynamic resistance(Pre-insertion resistor) 1 1 3 3 3 3 6 Static resistance 1 1 3 3 3 3 6 Ground resistance 3 6 Features ● It is suitable for the mechanical test of all types of SF6 switches, GIS combination appliances, vacuum switches and oil switches. ● Strong anti-interference ability. It ... -
OEM Best insulation tester Suppliers – GD3128 Series Insulation Resistance Tester – HV Hipot
General Information GD3128 series Insulation Resistance Tester has perfect testing function of various insulation resistance parameters and excellent anti-interference ability, which can be used to test the insulation resistance of large capacity high voltage electrical equipment and transmission lines in strong inductive environment such as substation. The instrument adopts true color touch screen, all test data and battery power are displayed on the same screen at a glance, and the combination of knob switch and key makes the operation very simple. The user does not need to memorize the operation method. Click “HELP” on the screen to pop up the operation method, which can effectively guide the user to operate the instrument. The instrument has the function of fast disch... -
China High Quality Transformer Voltage And Current Solution Factories – GDHG-108A CT/PT Tester – HV Hipot
GDHG-108A CT/PT Tester supports test voltage method to test bushings CTs which installed on transformer or inside switch-gear, suitable for the laboratory and on-site detection. Itcan be easily and conveniently done voltage current characteristic, transformer ratio, ratio and phase angle error, load test items on CT/PT. Features ● Using the voltage detection principle to measure CT and PT. ● To meet the requirements of GB1207, GB1208, GB168-47 (IEC60044-1.6) and other standards. ● No external auxiliary equipment, a single machine can complete all test items. ● With high speed micro printer: real-time print the test result. ● Using intelligent controller, operation is simple. ● 5inch LCD screen display. ● Automatically given CT/PT (excitation) knee point value. ● Auto display 5% and 1... -
China High Quality metering relay Supplier – GDJB-6000D Smart Substation Relay Protection Test System – HV Hipot
GDJB-6000D is equipped with high-performance power amplifier and based on the powerful PowerPC+X86 platform. It adopts modular design and have powerful functions, high precision, small size and light weight features. It can test the function and performance of merging unit, relay protection device, measurement and control device, intelligent terminals etc. Very suitable for power plants, substations, various scientific research units and equipment manufacturing enterprises. Features ● Smart Test Module Intelligent test template editing is supported. Test items can be randomly added during the test process and saved as reusable test project files to improve the test efficiency in the final stage of inspection and elimination. ● Automatic testing With on-site protection and digital pr... -
OEM Best A Bridge Used For The Measurement Of Capacitance Is Factories – Surge Generator for motor – HV Hipot
GDZJ-5S Turn to Turn Surge Withstand Tester GDZJ-5S is used to test turn-to-turn insulation strength of single-phase motor, 3-phase motor, Micro motor, Special motor, electrical motor, transformer (including switching mode power supply transformer), relay and winding electrical equipment. It can detect below faults: ● Turn-to-turn Insulation breakdown ● Corona discharge ● Winding connection mistake ● Winding disconnection ● Turn-to-turn difference ● Short-circuit between interphase, winding phase, or iron core Specifications ● Peak voltage: 500-5000V continuous adjustment ● Peak error: ≤ 5% (1kV-5kV) ● Waveform rising time: 0.5μS or 0.2μS ● Power supply: 220V±10%, 50HZ ● Power consumption: ≤ 100 W ● Dimension: 480*260*390mm ● Weight: about 24kg -
OEM Best Capacitance Voltage Measurement Factory – AC Resonant Test System for Generators GDTL – HV Hipot
GDTL series AC Resonant Test System for Generators can be used by adjusting inductance of the reactor, or adjusting the work way of resonant frequency of the system to achieve resonance. Both two methods can be used to achieve resonance. In the voltage boosting process, if the resonant point deviate, it can be found exactly by the way of fine tuning frequency, which ensure a high Q value and reduce power capacity and volume weight of test equipment. Features ● Smaller size,lighter weight compared with same voltage level,same capacity generator AC withstand voltage test equipment.Single equipment is no more than 60kg, easy to move. ● Advanced principle of whole set device and new frequency & inductance modulation technology, strictly ensure generator power frequency withstand volt... -
OEM Best lightning arrester testing Suppliers – GDYZ-302 Wireless Zinc Oxide Surge Arrester Tester – HV Hipot
Product Description GDYZ-302 Zinc Oxide Arrester Live Tester is a special instrument used to test the electrical performance of Zinc Oxide Arrester. It is suitable for live or power-off detection of Zinc Oxide Arrester of various voltage levels, so that to found dangerous defects such as dampness of internal insulation and aging of valve plates in time. The instrument is simple to operate and easy to use. The entire measurement process is controlled by an industrial computer. It can measure the full current, resistive current and its harmonics, power frequency reference voltage and harmonics, active power and phase difference. Displays true waveforms of voltage and current. The instrument uses digital waveform analysis technology and software anti-interference methods such as harmoni... -
OEM Best Meter Sf6 Leak Detection Factory – GDFJ-311M SF6 Gas Decomposition Product Tester – HV Hipot
General Information GDFJ-311M SF6 Gas Decomposition Product Tester is a portable device designed to measure SF6 gas decomposition product. The core component with electrochemical sensor from Membrapor to test SF6 gas decomposition product. Besides, we also adopt professional hardware chips and excellent software algorithms of STMicroelectronics. Application Decomposition product analysis of SF6 gas insulated electrical equipment Quality detection of recycled SF6 gas R&D use Reference standard DL/T 639-1997: Safety and Protection Guide for Operation Test and Maintenance Personnel of SF6 Electrical Equipment. Guodian No.72 Annex 3[1999] Measures for Quality Supervision and Management of High Voltage Switchgear. GB/T 17626: Electro-magnetic Compatibility – Testing and M... -
OEM Best measure ground resistance Manufacturer – GDWR-5A Earth Resistance Tester for Ground Grid – HV Hipot
Product Description GDWR-5A Earth Resistance Tester is a high-precision test instrument used in various fields such as substations for testing grounding resistance and related parameters. The instrument has the characteristics of small volume, light weight, convenient carrying, strong anti-interference performance and high accuracy. The instrument is an integrated structure, built-in variable frequency power supply module, and the output power supply is continuously variable frequency adjustable. The frequency can be changed to 45Hz or 55Hz, and the built-in high-speed processor core adopts high-end digital filtering technology, which effectively avoids the interference of the power frequency electric field to the test, and fundamentally solves the problem of accurate measurement und... -
China High Quality surface resistivity meter Factory – GDHX-9500 Phase Detector – HV Hipot
General Information GDHX-9500 Phase Detector is mainly used in electric power lines, phase and phase sequence calibration in substation, with main functions including electrical inspection, phase calibration and phase sequence measurement. It uses double shielding and brand new digital circuits, with strong anti-interference, accorded with EMC standards, suitable for various electromagnetic interference situations. The high voltage phase signal of measured lead will be transmitted directly after treatment, the handset will receive and make phase comparison, determine the results after phase detection, real-time display phase angle difference and vector.It uses wireless transmission technology, safe and reliable, fast and accurate, suitable for using at different voltage levels (6V-50...