Featured

  • OEM Best megger device Factory –  GD2000D Insulation Resistance Tester – HV Hipot

    OEM Best megger device Factory – GD2000D Insulation Resistance Tester – HV Hipot

    General Information GD2000D digital insulation resistance tester produced by our company uses an embedded industrial single chip real-time operating system. The digital analog pointer and digital field code display are perfectly combined. This series of meters has a variety of voltage output levels (250V, 500V, 1000V, 2500V, 5000V, 10000V), large capacity, strong anti-interference, analog pointer and digital synchronous display, AC and DC dual-use, simple operation, automatic calculation of various insulation indicators (absorption ratio, polarization index), various measurement results with anti-power-down function, etc. It is an ideal test instrument for measuring the insulation resistance of large-capacity transformers, transformers, generators, high-voltage motors, power capacito...
  • China High Quality Electric Cable Detector Suppliers –  GD-4136H Cable Fault Locating System  – HV Hipot

    China High Quality Electric Cable Detector Suppliers – GD-4136H Cable Fault Locating System – HV Hipot

    GD4136H Cable Fault system is an important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1.GD-2131H Impulse Generator 2.GD-4132 Cable Fault Locator 3.GD-4133 Multi-pulse Cable Fault Detector 4.GD-4133S Multi-pulse Coupler 5.Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-4133 Cable Fault Tester, there are two locating ways: a. Low vol...
  • China High Quality Underground Pipe Locator Manufacturers –  GDCF-900T Vehicle Mounted Cable Fault Locating System – HV Hipot

    China High Quality Underground Pipe Locator Manufacturers – GDCF-900T Vehicle Mounted Cable Fault Locating System – HV Hipot

    Vehicle Mounted Cable Fault Locator system is used for Cable Fault conditioning (burn-down), Pre-Location, Route Location, Pin-pointing & Testing of HV & LV cables of different types&sizes. The set is suitable to carrying out the above-mentioned multifunction on power cables of various voltage levels mainly 33KV, 11KV, 415V and control cables with 1.1 KV grade. The set shall be used for cable types namely XLPE, PVC, PILC with Al / Cu conductor. The cables are laid underground (under plain earth, trenches, or RCC surface, Horizontal Drilling in HDD Pipe), above ground or partly under & partly above ground with maximum cable length around 25Km. The cable fault locator is suitable for fault locating and pinpointing the following types of cable faults. ● High resistance ● L...
  • China High Quality Circuit Breaker Testing Manufacturers –  GDKC-12A (GDKC-12B) (GDKC-13A) Circuit Breaker Analyzer – HV Hipot

    China High Quality Circuit Breaker Testing Manufacturers – GDKC-12A (GDKC-12B) (GDKC-13A) Circuit Breaker Analyzer – HV Hipot

    General Information High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-12A/B (GDKC-13A) is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy. Features ● Time: the open/close time, in phase synchronization, phase-to-phase synchronization of 12contacts. ● Closing resistor: pre-switching time, pre-switching waveform and resistance of the closing resistor of 6 channels. ● Reclosure: close-open, open-close, open-close-open time for each contact. ● Bounce: close bounce time, times, process and waveform of each contacts. ● Velocity: velocity at contact open or close, maximum speed, time-travel characteristic curve; first open, first close and second open velocity of reclosure. ●...
  • OEM Best Switch Testing Manufacturers –  GDKC-12A (GDKC-12B) (GDKC-13A) Circuit Breaker Analyzer – HV Hipot

    OEM Best Switch Testing Manufacturers – GDKC-12A (GDKC-12B) (GDKC-13A) Circuit Breaker Analyzer – HV Hipot

    General Information High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-12A/B (GDKC-13A) is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy. Features ● Time: the open/close time, in phase synchronization, phase-to-phase synchronization of 12contacts. ● Closing resistor: pre-switching time, pre-switching waveform and resistance of the closing resistor of 6 channels. ● Reclosure: close-open, open-close, open-close-open time for each contact. ● Bounce: close bounce time, times, process and waveform of each contacts. ● Velocity: velocity at contact open or close, maximum speed, time-travel characteristic curve; first open, first close and second open velocity of reclosure. ●...
  • China High Quality instrument transformer Manufacturers –  GDJF-2008 Partial Discharge Analyzer – HV Hipot

    China High Quality instrument transformer Manufacturers – GDJF-2008 Partial Discharge Analyzer – HV Hipot

    GDJF-2008 Partial Discharge Detector is measuring partial discharge for the products such as transformers, mutual inductors, HV switches, zinc monoxide arresters and power cables. It also can make type tests and monitor insulation operation. This type has the advantages of high sensitivity, wide range of capacitance, being well equipped for input unit impedance detecting and more variants of frequency bands (9 in all). After proper setting, the discharge impulse amount can be read directly. The indicating and digital meters are shown simultaneously. This detector is widely applied in power stations, manufacturers, and institutions. Use Condition ● Ambient temperature: 0-40℃±2℃. ● Relative humidity: ≤80% ● Power supply: 220V±10%, 50HZ. ● No violent vibration and mechanical shock. ● Th...
  • OEM Best Electrical Cable Fault Locator Supplier –  GD-4138H Cable Fault Locating System – HV Hipot

    OEM Best Electrical Cable Fault Locator Supplier – GD-4138H Cable Fault Locating System – HV Hipot

    GD-4138H Mobile Cable Fault Locating System is important tool to maintain all kinds of cables. It is compatible equipment that can trace, locate the underground cables, with fault distance measurement and HV generation. As it is movable device, it is convenient to carry on-site. If acoustic locator is used together, it can locate accurate position of cable fault point. Application is underground cable, aerial cable, power cable, local cable, communication cable and fiber cable. Typical fault to be detected includes ● High impedance flash-over fault ● High impedance leak ● High/low resistive grounding ● Short-circuit fault ● Open-circuit fault ● Poor connection/Disconnection GD-4138L system includes ● GD-4138H main frame (Coupling device, Sphere gap, HV generator are inside) ● GD-...
  • OEM Best protective relay test system Supplier –  GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot

    OEM Best protective relay test system Supplier – GDJB-1200A Six Phase Relay Protection Test Set – HV Hipot

    Features ● Output up to 6-phase voltage 6-phase current, which can be combined to realize conventional 4-phase voltage 3-phase current type, 6-phase voltage type, 6-phase current type, and 12-phase output mode. ● High-performance embedded industrial control computer and 8.4-inch large-screen high-resolution color TFT liquid crystal display, which can provide rich and intuitive information, including the current working status of the device, next working tips and various help information; ● The output uses a high-fidelity, high-reliability modular linear power amplifier instead of a switch-type power amplifier for superior performance. It will not generate high and medium frequency interference to the test site, and it will ensure excellent waveform smoothing and accuracy from high cu...
  • China High Quality partial discharge test Manufacturer –  GD-610C Remote Ultrasonic Partial Discharge Detector – HV Hipot

    China High Quality partial discharge test Manufacturer – GD-610C Remote Ultrasonic Partial Discharge Detector – HV Hipot

    Partial discharge is one of the common reasons of medium and high voltage equipment and cable insulation failures. Partial discharge testing can detect harmful defects and help identify potential future failures. The GD-610C remote ultrasonic partial discharge detector uses an ultrasonic spectrum probe (sensor) to collect ultrasonic signals and analyze the signal to diagnose the charged detection, it is a diagnosis device for the accident of the distribution line. The device determines the line position and the fault type of the faulty hidden line when it is live. After collecting the ultrasonic abnormal signal, it transmits signals to the host, converts it into an audible sound signal and waveform, and finally diagnoses the type of the hidden danger and grade by the analysis software. ...
  • China High Quality uhf detectorDigital Pd Detector Factories –  GDPD-414H Handheld Partial Discharge Detector – HV Hipot

    China High Quality uhf detectorDigital Pd Detector Factories – GDPD-414H Handheld Partial Discharge Detector – HV Hipot

    Pictures for reference only. The GDPD-414H handheld Partial Discharge Detector adopts smart quick intelligent power test system (Soft No. 1010215, trademark registration number 14684481). It can flexibly configure various sensors according to different products to be tested. TEV, ultrasonic and HFCT are suitable for partial discharge detection of high-voltage switchgear and ring network cabinet; Ultrasonic and UHF are suitable for detecting GIS; Ultrasonic and HFCT are suitable for testing power cable. The built-in expert diagnosis system can analyze the test data and judge the discharge energy and possible parts. It is widely used in electric power and railway. Features ● Portable ABS engineering chassis. All PD detection hosts, tablets, sensors, chargers and signal cables are placed...
  • OEM Best Price Of Primary Injector Exporters –  GDSL-BX-200 Primary Current Injection Test Set – HV Hipot

    OEM Best Price Of Primary Injector Exporters – GDSL-BX-200 Primary Current Injection Test Set – HV Hipot

    Features ● Digital control, high anti reference ability. ● Adapts autotransformer regulator which with low power consumption and large capacitance. ● Converter has high permeability core. ● Quick connects, lock design, have good current capability. ● PVC panel. ● Build-in quick plug with high safety. ● Current range can be changed, easy to read. ● Engineering plastics box, IP67 dustproof and waterproof. ● Portable design is suitable for on-site testing. ● Zero start function to prevent the test objects from damage caused by high current impulsing. The equipment only can be started at zero. ● Impulse choosing function: The current value can be outputted directly without zero protection function when the equipment is under the testing for circuit breaker. ● 0-50A AC current can be outp...
  • OEM Best lightning arrester tester Factory –  GDYZ-301A Zinc Oxide Surge Arrester Tester – HV Hipot

    OEM Best lightning arrester tester Factory – GDYZ-301A Zinc Oxide Surge Arrester Tester – HV Hipot

    It is the special equipment of testing zinc oxide electric performance. The instrument can accurately and stably measure the arrester resistive current and the monitor counter action parameters while the equipment is running. It can also check the monitor ammeter.  Features ● 8inch color LCD touch screen, high speed thermal printer. ● The measurement data of wire and wireless is the same. ● Wireless sampling, with long distance. A. Wired: indoor use, or on-site where the PT sampling wiring cabinet is near with tested lightning arrester. B. Wireless: outdoor use, or on-site where the PT sampling wiring cabinet is far from tested lightning arrester, wireless distance is up to 1000M. ● Three-phase can be measured at the same time. The resistive current of 3channels can be measured at ...

Send your message to us:

Write your message here and send it to us