  • China High Quality Electric Cable Locator Factories –  GD-2136H Cable Fault Locating System – HV Hipot

    China High Quality Electric Cable Locator Factories – GD-2136H Cable Fault Locating System – HV Hipot

    GD2136H Cable Fault system is important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1. GD-2131H Impulse Generator 2. GD-2132 Cable Fault Locator 3. GD-2133 Cable Fault Tester 4. Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-2133 Cable Fault Tester, there are two locating ways: a. Low voltage pulse: If only using GD-2133, open circ...
  • China High Quality Electric Cable Detector Factories –  GD-2136H Cable Fault Locating System – HV Hipot

    China High Quality Electric Cable Detector Factories – GD-2136H Cable Fault Locating System – HV Hipot

    GD2136H Cable Fault system is important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1. GD-2131H Impulse Generator 2. GD-2132 Cable Fault Locator 3. GD-2133 Cable Fault Tester 4. Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-2133 Cable Fault Tester, there are two locating ways: a. Low voltage pulse: If only using GD-2133, open circ...
  • OEM Best electrical earth testing Suppliers –  GDHX-9700 Phase Detector – HV Hipot

    OEM Best electrical earth testing Suppliers – GDHX-9700 Phase Detector – HV Hipot

    General Information GDHX-9700 Phase Detector is mainly used in electric power lines, phase, and phase sequence calibration in substation, with main functions including electrical inspection, phase calibration and phase sequence measurement. It uses double shielding and brand-new digital circuits, with strong anti-interference, accorded with EMC standards, suitable for various electromagnetic interference situations. The high voltage phase signal of measured lead will be transmitted directly after treatment, the handset will receive and make phase comparison, determine the results after phase detection, real-time display phase angle difference and vector. It uses wireless transmission technology, safe and reliable, fast, and accurate, suitable for using at different voltage levels (10...
  • OEM Best Type Test Circuit Breaker Factory –  GDZK-IV Vacuum Degree Tester for Vacuum Breaker – HV Hipot

    OEM Best Type Test Circuit Breaker Factory – GDZK-IV Vacuum Degree Tester for Vacuum Breaker – HV Hipot

    Features ● Measure vacuum degree in vacuum interrupter for every types of breakers. ● Electromagnetic measuring method, Accurate and Reliable. ● No need to dismantle the vacuum breaker in measurement. ● 128*64 pixel LCD screen, easy to operate. The test results are directly compared with the standard values to determine whether they are qualified;Save, print and check testing data. ● RS-232 port, connecting with PC to download vacuum degree-ionic current curve, to estimate lifespan. ● Light weight, Portable. Specifications ● Power Supply: AC220V ± 20%, 50Hz. ● Testing Range: 10-5 ~10-1Pa. ● Electric field Voltage: 20kV. ● Magnetic field Voltage: 1600V. ● Accuracy: 20%-25% at 10-5 ~10-4. 15%-20% at 10-4 ~10-3 10%-15% at 10-3 ~10-2 5%-10% at 10-2 ~10-1 ● Ambient Temperature:  -1...
  • China High Quality Tension test kit Factories –  GDND-800 Freezing Point Tester – HV Hipot

    China High Quality Tension test kit Factories – GDND-800 Freezing Point Tester – HV Hipot

    General Information  1. Transformer oil freezing point tester has the characteristics of exquisite structural design and unique manufacturing process. It conforms to GB/T 3535 and GB/T510 standards and is used to determine the pour point of petroleum products. 2. This instrument adopts compressor refrigeration technology to save energy, simple operation and long service life. Its main technical indicators such as cooling rate and cooling capacity have surpassed similar foreign products. Working conditions 1. The instrument should be placed on a flat and stable workbench, and air convection should be minimized in the environment. 2. This product may involve flammable materials when used. It is not allowed to have an open flame (or a device that produces spark) close to it during op...
  • OEM Best grounding measurement Exporters –  GD3128 Series Insulation Resistance Tester – HV Hipot

    OEM Best grounding measurement Exporters – GD3128 Series Insulation Resistance Tester – HV Hipot

    General Information GD3128 series Insulation Resistance Tester has perfect testing function of various insulation resistance parameters and excellent anti-interference ability, which can be used to test the insulation resistance of large capacity high voltage electrical equipment and transmission lines in strong inductive environment such as substation. The instrument adopts true color touch screen, all test data and battery power are displayed on the same screen at a glance, and the combination of knob switch and key makes the operation very simple. The user does not need to memorize the operation method. Click “HELP” on the screen to pop up the operation method, which can effectively guide the user to operate the instrument. The instrument has the function of fast disch...
  • OEM Best digital earth resistance tester price Manufacturers –  GDF-3000 DC System Earth Fault Detector – HV Hipot

    OEM Best digital earth resistance tester price Manufacturers – GDF-3000 DC System Earth Fault Detector – HV Hipot

    General Information In DC system, there are many earth faults including indirect earth fault, non-metal earth fault, loop earth fault, positive and negative earthing fault, positive and negative balance earth fault, multi-point earth fault. GDF-3000 Earth Fault Tester for DC System locates these earth faults and displays the parameters of system voltage, earth voltage, earth resistance and earth impedance of branches accurately. Functions ● System ground voltage measurement function, the instrument can measure the system ground voltage, negative to ground voltage, system voltage, can achieve 0-300V voltage monitoring range. ● System insulation impedance measurement function, the instrument can measure the positive to ground insulation impedance and the negative to ground insulatio...
  • OEM Best Cold Mirror Dew Point Tester Exporters –  GDSF-311WP SF6 Dew Point and Purity Tester  – HV Hipot

    OEM Best Cold Mirror Dew Point Tester Exporters – GDSF-311WP SF6 Dew Point and Purity Tester – HV Hipot

    General Information GDSF-311WP is ideal instrument when it is necessary to test water content and purity of SF6 gas. The core component is DRYCAP series sensors produced by Finland Vaisala company. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of gas moisture test instrument. Application ● Moisture monitoring of SF6 gas electrical equipment for electric power ● SF6 gas cylinder gas quality test ● High purity gas manufacturing ● Semiconductor industry dry gas supply ● Research and development use ● Clean room/dry house monitoring ● Metal heat treatment site and laboratory industrial gas humidity detection, such as air, CO2, N2, H2, O2, SF6, He, Ar and other inert gases. Features Specification SF6 ...
  • OEM Best Capacitor Is Measured In Exporters –  Turn-to-turn Surge Tester – HV Hipot

    OEM Best Capacitor Is Measured In Exporters – Turn-to-turn Surge Tester – HV Hipot

    GDZJ-10S Turn to Turn Surge Withstand Testerh GDZJ-10S is used to test turn-to-turn insulation strength of single phase motor, 3-phase motor, Micro motor, Special motor, electrical motor, transformer (including switching mode power supply transformer), relay and winding electrical equipment. Features It can detect below faults: ● Turn-to-turn Insulation breakdown ● Corona discharge ● Winding connection mistake ● Winding disconnection ● Turn-to-turn difference ● Short-circuit between inter-phase, winding phase, or iron core Specifications ● Peak voltage: 500-10kV continuous adjustment ● Peak error: ≤ 5%(1kV-5kV) ● Waveform rising time: 0.5μS or 0.2μS ● Power supply: 220V±10%, 50Hz ● Power consumption: ≤ 800 W ● Dimension: 900*460*550mm ● Weight: about 70kg Important Tips GDZJ...
  • China High Quality Ct Meter Type Supplier –  GDHG-108A CT/PT Tester – HV Hipot

    China High Quality Ct Meter Type Supplier – GDHG-108A CT/PT Tester – HV Hipot

    GDHG-108A CT/PT Tester supports test voltage method to test bushings CTs which installed on transformer or inside switch-gear, suitable for the laboratory and on-site detection. Itcan be easily and conveniently done voltage current characteristic, transformer ratio, ratio and phase angle error, load test items on CT/PT. Features ● Using the voltage detection principle to measure CT and PT. ● To meet the requirements of GB1207, GB1208, GB168-47 (IEC60044-1.6) and other standards. ● No external auxiliary equipment, a single machine can complete all test items. ● With high speed micro printer: real-time print the test result. ● Using intelligent controller, operation is simple. ● 5inch LCD screen display. ● Automatically given CT/PT (excitation) knee point value. ● Auto display 5% and 1...
  • OEM Best Gas Leak Detector Supplier Manufacturers –  GDIR-1000L SF6 Gas Infrared Imaging Leak Detector – HV Hipot

    OEM Best Gas Leak Detector Supplier Manufacturers – GDIR-1000L SF6 Gas Infrared Imaging Leak Detector – HV Hipot

    Product Description GDIR-1000L SF6 Gas Infrared Imaging Leak Detector is a highly technical instrument which is independently developed by our company and has independent intellectual property rights. It is specially used to directly observe the leakage of SF6 gas equipment in the operation of the electric power industry. It uses infrared imaging principle and unique image processing algorithm, to ensure test sensitivity and reducibility of the instrument. Simple and reliable operation, high test sensitivity, the image is intuitionistic and clear, able to find the SF6 gas leakage point of the electrical equipment accurately and quickly. Features ● Infrared imaging detection, visualization. ● Fast Start-up, no need to warm up, and 10 seconds can be put into detection. ● No need for...
  • OEM Best Cable Fault Location System Supplier –  GD-2134E  Cable Identifier – HV Hipot

    OEM Best Cable Fault Location System Supplier – GD-2134E Cable Identifier – HV Hipot

    GD-2134E is a high-performance underground metal pipeline detection system composed of signal transmitters and receivers. It can be used for path detection, pipeline survey and depth measurement of metal pipelines and underground cables. It can carry out uniqueness identification with a variety of selected accessories, as well as pipe insulation damage and the search for some types of cable faults. Features ● Compass display: intuitively displays the pipeline location and left & right directions. ● Tracking true and false prompts: current direction measurement, tracking correct error prompts, eliminating line interference (some frequencies). ● Depth and current measurements, can display the signal strength historical curve. ● Fully digital high-precision sampling processing: sta...