Featured

  • China High Quality Single Stage Impulse Generator Manufacturer –  GDZRC-10H Hand-held Transformer DC Winding Resistance Tester – HV Hipot

    China High Quality Single Stage Impulse Generator Manufacturer – GDZRC-10H Hand-held Transformer DC Winding Resistance Tester – HV Hipot

    Features ● Lithium battery power supply and 220V AC power supply. charge once, continuous testing hundreds of transformers, simple operation, more convenient. ● Output 6 steps of current, Max. output current 10A, Max. output voltage 25V, and current step can be automatically selected. Wide range of 500uΩ~50 kΩ. ● With the resistance temperature conversion function, and wireless temperature measurement module can be selected, real-time measurement of field sample temperature, to ensure the accuracy of resistance conversion value. ● With a variety of protection functions such as counter electromotive force protection, wire breakage protection, powed-off protection, overheating alarm, etc. ● 5.6-inch industrial grade high brightness color LCD screen, the display is still clearly visible in...
  • OEM Best harga megger Manufacturer –  GDCR3000 Digital Earth Resistance Tester – HV Hipot

    OEM Best harga megger Manufacturer – GDCR3000 Digital Earth Resistance Tester – HV Hipot

    General Information GDCR3000 Digital Earth Resistance Tester is specially designed and manufactured for field measurement, adopting the latest digital and micro-processing technology, 3-pole or 2-pole method for earth resistance measurement, with a unique function of wire resistance verification, anti-interference capability and the ability to adapt to the environment, to ensure high precision, high stability and reliability for prolonged measure, which is widely used in electric power, telecommunications, meteorology, oil field, construction, lightning protection, industrial electrical equipment and other earth ground resistance measurement. Measurement range & Accuracy Measurement function Range Accuracy Resolution Earth resistance 0.01Ω~20Ω ±2%rdg ±3dgt (Auxiliary ear...
  • China High Quality earth resistevity testing Factory –  GDDT-10U Digital Grounding Down Lead Earth Continuity Tester – HV Hipot

    China High Quality earth resistevity testing Factory – GDDT-10U Digital Grounding Down Lead Earth Continuity Tester – HV Hipot

    General Information GDDT-10U Earth Continuity Resistance Tester is a highly automatic and portable test equipment. It is applied to the measurement of breakover resistance value among earth connecting cables of substation electrical equipment. The adoption of high-performance single-chip control helps to achieve intelligence of testing process. It is small size, convenient to carry, easy to operate, high-accuracy, fast testing speed, good testing repeatability, clear to read. Features ● The instrument is controlled by high-speed single chip, thus it’s highly automatic and easy to operate.  ● Using new power source technology, with many more current steps and wide measuring range. ● Intelligent power management technology, the instrument can work in the state of Min. power, w...
  • OEM Best Arrester meter Suppliers –  GDUD-PBI Ultrasonic Flaw Detector for Electrical Equipment – HV Hipot

    OEM Best Arrester meter Suppliers – GDUD-PBI Ultrasonic Flaw Detector for Electrical Equipment – HV Hipot

    Applications It detects internal flaws of electrical equipment, such as bushings, bus bars, wire clamps, transformer tank, current&voltage transformers, surge arresters, generator bearing equipment, and porcelain pillar type insulators, etc. Features ● TFT true color screen. ● High accuracy and wide applications. ● High sensitivity of flaw detection, up to 110db. ● Built-in standard curves and test block for pillar type insulators. The device alarms if internal crackle flaws are super-standard. ● Automatic calibrations for probe and curvature surface, which optimizes the coupling between the probe and test object and ensures accuracy. ● Aluminum alloy chassis, which has excellent anti-interference performance. Low noise and high signal-to-noise ratio. Specifications ● Worki...
  • OEM Best Electric Cable Detector Exporters –  GD-2136H Cable Fault Locating System – HV Hipot

    OEM Best Electric Cable Detector Exporters – GD-2136H Cable Fault Locating System – HV Hipot

    GD2136H Cable Fault system is important tool to maintain all kinds of cables. It uses various detection way to test cable faults, which is suitable for different levels voltage power cables and communication cables. The system contains below units: 1. GD-2131H Impulse Generator 2. GD-2132 Cable Fault Locator 3. GD-2133 Cable Fault Tester 4. Other accessories GD-2131H Impulse Generator It’s used to generate HV impulse when using impulse flashover method to detect high impedance fault. Features ● Strong burning ability, max.burning power is 1000W, breakdown point can be burned in short time and the resistance of breakdown point is decreased. ● If working together with GD-2133 Cable Fault Tester, there are two locating ways: a. Low voltage pulse: If only using GD-2133, open circ...
  • China High Quality Open Current Transformer Factory –  GDHG-108A CT/PT Tester – HV Hipot

    China High Quality Open Current Transformer Factory – GDHG-108A CT/PT Tester – HV Hipot

    GDHG-108A CT/PT Tester supports test voltage method to test bushings CTs which installed on transformer or inside switch-gear, suitable for the laboratory and on-site detection. Itcan be easily and conveniently done voltage current characteristic, transformer ratio, ratio and phase angle error, load test items on CT/PT. Features ● Using the voltage detection principle to measure CT and PT. ● To meet the requirements of GB1207, GB1208, GB168-47 (IEC60044-1.6) and other standards. ● No external auxiliary equipment, a single machine can complete all test items. ● With high speed micro printer: real-time print the test result. ● Using intelligent controller, operation is simple. ● 5inch LCD screen display. ● Automatically given CT/PT (excitation) knee point value. ● Auto display 5% and 1...
  • China High Quality tester earth insulation Manufacturers –  GD2000H 10kV Insulation Resistance Tester – HV Hipot

    China High Quality tester earth insulation Manufacturers – GD2000H 10kV Insulation Resistance Tester – HV Hipot

    General Information This device can test insulation resistance (such as transformer, switchgear, leads, motor) of different modules in one system, to insulate and repair failure components. It is important to ensure products quality and security of person and equipment during operation by insulation test of checking test object to ground or adjacent conductors’ insulation. Before power on the system, use insulation test to verify if it is good to improve system performance. Insulation test is to find manufacturing process problems and equipment fault which can’t be found before failure happened. In EU, this test is compulsory, even to civil system. Features 1. Voltage output GD2000H (5kV/10kV).Resistance range 0-400GΩ. 2. Two modes display insulation resistance. 3. Aut...
  • OEM Best Automotive Circuit Breaker Tester Suppliers –  GDZK-IV Vacuum Degree Tester for Vacuum Breaker – HV Hipot

    OEM Best Automotive Circuit Breaker Tester Suppliers – GDZK-IV Vacuum Degree Tester for Vacuum Breaker – HV Hipot

    Features ● Measure vacuum degree in vacuum interrupter for every types of breakers. ● Electromagnetic measuring method, Accurate and Reliable. ● No need to dismantle the vacuum breaker in measurement. ● 128*64 pixel LCD screen, easy to operate. The test results are directly compared with the standard values to determine whether they are qualified;Save, print and check testing data. ● RS-232 port, connecting with PC to download vacuum degree-ionic current curve, to estimate lifespan. ● Light weight, Portable. Specifications ● Power Supply: AC220V ± 20%, 50Hz. ● Testing Range: 10-5 ~10-1Pa. ● Electric field Voltage: 20kV. ● Magnetic field Voltage: 1600V. ● Accuracy: 20%-25% at 10-5 ~10-4. 15%-20% at 10-4 ~10-3 10%-15% at 10-3 ~10-2 5%-10% at 10-2 ~10-1 ● Ambient Temperature:  -1...
  • OEM Best relay test equipment Manufacturers –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot

    OEM Best relay test equipment Manufacturers – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot

    Features A. Working conditions 1. Power supply: AC 220V±10%,50Hz 2. Working environment: Temperature -10℃~40℃; Humidity: ≤85% 3. Atmosphere: 86-106kPa B. Output power supply 1. AC voltage: 0-220V/3A  Adjustable 2. AC current: 0-100A/7V (200A can be customized);  0-20A/25V  Adjustable; 0-5A/5V  Adjustable 3. DC voltage: 0-220V/3A  Adjustable 4. DC current:0-20A/25V 5. Fixed voltage output: DC 24V/48V/110V/220V 6. Current/Voltage accuracy: ±1%. C. Performance Index 1. Ammeter and voltmeter: 41/2 digit. 2. Digital millisecond meter: 0-99.9999s(999.999s can be customized) Resolution: 0.1ms. D. Functions 1. Measure relay: Measure start value, return value and drop-off to pick-up ratio of current, voltage relay. 2. Time relay: Measure start value, return value and action time. 3. Intermed...
  • China High Quality Vlf Tester Price Exporters –  Insulation Materials Hipot Test Set GDJS-65 – HV Hipot

    China High Quality Vlf Tester Price Exporters – Insulation Materials Hipot Test Set GDJS-65 – HV Hipot

    GDJS-65 Insulation Gloves Test Set It is used to test insulation performance for insulation gloves, boots, mats, hats, rod, Electroscope etc. It can test 6pcs insulation gloves/boots at the same time, also 5pcs insulation rods. Features Manual control unit ● Digital and real time display HV voltage, LV current, 6-way leak current and time. ● With leak current meter and over-current protection meter. ● With movable control unit, easy wiring and testing. ● Manual control, safety and reliability. ● With zero, power, operation, timing indicators. ● With over-current protection, zero-start protection, sound and light alarm, power protected switch. ● New type timer, broader timing range.(1s-99h). Other features ● HV source is oil immersed type testing transformer.(dry type and SF6 gas t...
  • OEM Best omicron relay test set Exporters –  GDJB-6000D Smart Substation Relay Protection Test System – HV Hipot

    OEM Best omicron relay test set Exporters – GDJB-6000D Smart Substation Relay Protection Test System – HV Hipot

    GDJB-6000D is equipped with high-performance power amplifier and based on the powerful PowerPC+X86 platform. It adopts modular design and have powerful functions, high precision, small size and light weight features. It can test the function and performance of merging unit, relay protection device, measurement and control device, intelligent terminals etc. Very suitable for power plants, substations, various scientific research units and equipment manufacturing enterprises.  Features ● Smart Test Module Intelligent test template editing is supported. Test items can be randomly added during the test process and saved as reusable test project files to improve the test efficiency in the final stage of inspection and elimination. ● Automatic testing With on-site protection and digital pr...
  • China High Quality Capacitor Meter Price Manufacturers –  VLF AC Hipot Test Set – HV Hipot

    China High Quality Capacitor Meter Price Manufacturers – VLF AC Hipot Test Set – HV Hipot

    Withstand voltage test is an essential preventive test for electrical equipment. It is divided into two parts: AC and DC withstand voltage test. AC test can be further divided into power frequency, variable frequency and 0.1Hz very low frequency test, among which the last one is highly recommended by IEC, due to its remarkable advantages. Following is a comparison for DC, Power Frequency, Variable Frequency, and 0.1Hz test. Aspects DC Power Frequency Variable Frequency 0.1Hz Equivalency poor good good good Insulation Damage strong slight slight slight Operation Safety relatively low relatively low relatively low high Wiring Difficulty complicated complicated most complicated simple Volume smallest largest large smal...