-
OEM Best Ir Gas Leak Detectors Suppliers – GDP-311IR SF6 Gas Purity Tester (IR Method) – HV Hipot
General Information GDP-311IR SF6 gas purity tester is a portable instrument for on site SF6 gas purity test developed by our company. The infrared principle SF6 gas purity testing sensor manufactured by European Sensor Company is used to test the purity of SF6 gas. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of SF6 gas purity analyzer. Application ● Analysis purity of SF6 gas electrical equipment for electric power ● SF6 gas cylinder gas quality test ● Quality test of SF6 gas for recovery and reuse ● High purity gas manufacturing ● Semiconductor industry dry gas supply ● Research and development use ● Clean room/dry house monitoring Features ● Imported high-precision sensors with self-calibration ... -
OEM Best Current Injection Test Set India Factory – GDSL-A Automatic 3-phase Primary Current Injection Test Set with Temperature Test – HV Hipot
Features ● Built-in high configuration industrial control computer, the programmable logic controller (PLC) as the central processor, real-time scan of AC signal, to achieve comprehensive monitoring and closed-loop control, and design password settings management, only the personnel who gets corresponding operation authority, can carry out operation of certain functions. ● Color LCD touch screen. Using intelligent sensor based on field bus technology and realize the full digital data transmission, display operation unit is touch type color LCD screen, full English menu, the interface is clear and intuitive, the operation is simple and convenient. Test without any auxiliary equipment, automatic control, fast, simple and convenient. ● Automatic and manual test mode, with automatic constan... -
OEM Best Best Cable Locator Factory – GD-2134A Cable Identifier – HV Hipot
The purpose of the cable identifier is to accurately identify one of the target cables from multiple cables and avoid serious accidents caused by wrong sawing of live cables. Cable identification starts from the operation of both ends of the cable, it must be ensured that the double number on both ends of the cable is accurate. GD-2134A Cable Identifier is only suitable for on-site identification of de-energized cables. It is strictly forbidden to connect the cable identifier to the running power cable! Features ● Handheld receiver automatically identify and display the results to ensure that the results of cable identification are 100% accurate. Light weight and powerful, easy to carry. ● Suitable for on-site identification of de-energized cables. ● Both transmitter and handheld re... -
OEM Best Blocking Cap Manufacturers – 30kVA.200kV Automatic AC.DC Hipot Test Set GDYD-2030A – HV Hipot
Features ● 7inch color LCD screen, with PLC automation control. ● HV Voltage, LV voltage, LC current measured at the same time, with high precision sensor and high-performance collection chip. ● Automatic mode and manual mode for option. ● Display HV voltage, LV voltage, LV current, time, and withstanding result. ● Over-voltage and over-current protection. Output voltage, HV current upper limit, LV current upper limit and timing can be set. ● Zero-starting function. Test can be proceeded after the voltage is back to zero. ● Store up to 8000pcs data in 3months. It has USB port to upload data to USB disk. ● When setting voltage is arrived, it will be timing automatically. After timing, voltage will be back to zero. ● When the LV current is over setting value, the voltage will be cut of... -
China High Quality how to measure dew point Manufacturers – GDYN-901 Kinematic viscosity tester – HV Hipot
General Information GDYN901 is suitable to determine kinematic viscosity of liquid petroleum products. This apparatus has the function of timing of the trial sample movement and can calculate the final result of kinematic viscosity. This method is suitable to determine kinematic viscosity of liquid petroleum products (It refers to Newtonian liquids ), and its unit is m2/s. Generally in actual utilization, the unit is mm2/s. The dynamic viscosity is equal with the result which use kinematic viscosity to multiply the density of the liquid. By this method, it can determine the time that the liquid with the certain volume flows past the calibrated glass capillary viscometer under the gravity in the certain stable temperature and the value that the constant value of capillary in the visc... -
China High Quality High Voltage Meter Supplier – GDCL-10kA Impulse Current Generator – HV Hipot
Working Environment ● Environmental temperature: -10℃ to 40℃ ● Related humidity: ≤ 85% RH ● Altitude: ≤ 1000m ● Indoor use ● No conductive dust, no fire or explosive danger, no corrosive metal or insulation gas. ● Power voltage waveform is sine wave, distortion rate <5% ● Earth resistance is no more than 1Ω. Applied Standard IEC60099-4: 2014 Surge Arresters-Part 4: Metal-oxide surge arresters without gaps for a.c. systems. GB311.1-1997 Insulation coordination of HV Power transmission and transformation. IEC 60060-1 High Voltage Testing Technique- General Testing Requirement. IEC 60060-2 High Voltage Testing Technique- Measurement System. GB/T16896.1-1997 Digital Recorder of High Voltage Impulse Test. DLT992-2006 Implementing Rules for Impulse Voltage Measurement. DL/T613-1997 T... -
China High Quality Series Of Capacitors Manufacturers – Turn-to-turn Surge Tester – HV Hipot
GDZJ-10S Turn to Turn Surge Withstand Testerh GDZJ-10S is used to test turn-to-turn insulation strength of single phase motor, 3-phase motor, Micro motor, Special motor, electrical motor, transformer (including switching mode power supply transformer), relay and winding electrical equipment. Features It can detect below faults: ● Turn-to-turn Insulation breakdown ● Corona discharge ● Winding connection mistake ● Winding disconnection ● Turn-to-turn difference ● Short-circuit between inter-phase, winding phase, or iron core Specifications ● Peak voltage: 500-10kV continuous adjustment ● Peak error: ≤ 5%(1kV-5kV) ● Waveform rising time: 0.5μS or 0.2μS ● Power supply: 220V±10%, 50Hz ● Power consumption: ≤ 800 W ● Dimension: 900*460*550mm ● Weight: about 70kg Important Tips GDZJ... -
OEM Best Iec Standards For Tan Delta Test Factory – Turn-to-turn Surge Tester – HV Hipot
GDZJ-10S Turn to Turn Surge Withstand Testerh GDZJ-10S is used to test turn-to-turn insulation strength of single phase motor, 3-phase motor, Micro motor, Special motor, electrical motor, transformer (including switching mode power supply transformer), relay and winding electrical equipment. Features It can detect below faults: ● Turn-to-turn Insulation breakdown ● Corona discharge ● Winding connection mistake ● Winding disconnection ● Turn-to-turn difference ● Short-circuit between inter-phase, winding phase, or iron core Specifications ● Peak voltage: 500-10kV continuous adjustment ● Peak error: ≤ 5%(1kV-5kV) ● Waveform rising time: 0.5μS or 0.2μS ● Power supply: 220V±10%, 50Hz ● Power consumption: ≤ 800 W ● Dimension: 900*460*550mm ● Weight: about 70kg Important Tips GDZJ... -
China High Quality Series Capacitance Voltmeter Manufacturers – AC Inductance Resonance Test System for CVT – HV Hipot
GDTL AC Resonant Test System for CVT is series resonance with power frequency specially for CVT. It is smaller size and more lighter weight than traditional device, meet various CVT inspection requirements of voltage with 35kV, 66kV, 110kV, 220kV, 330kV, 500kV. According to customer’s requirement, the reactor can be divided into fixed and adjustable reactor. Features ● Small size, light weight, simple wiring. ● Dry or Oil type reactor, high mechanical strength, good insulation, high reliability. ● Large capacity margin, good output waveform, easy to operate. ● Fully protection function: zero protection, over-voltage protection, over-current protect functions. -
China High Quality Sf6 Gas Leak Detection And Analysis Exporters – GDFJ-311M SF6 Gas Decomposition Product Tester – HV Hipot
General Information GDFJ-311M SF6 Gas Decomposition Product Tester is a portable device designed to measure SF6 gas decomposition product. The core component with electrochemical sensor from Membrapor to test SF6 gas decomposition product. Besides, we also adopt professional hardware chips and excellent software algorithms of STMicroelectronics. Application Decomposition product analysis of SF6 gas insulated electrical equipment Quality detection of recycled SF6 gas R&D use Reference standard DL/T 639-1997: Safety and Protection Guide for Operation Test and Maintenance Personnel of SF6 Electrical Equipment. Guodian No.72 Annex 3[1999] Measures for Quality Supervision and Management of High Voltage Switchgear. GB/T 17626: Electro-magnetic Compatibility – Testing and M... -
China High Quality soil resistivity test Factories – GDF-3000A DC System Earth Fault Detector – HV Hipot
General Information DC system insulation faults, DC mutual faults and AC power failures are faults that are prone to occur and are harmful to the power system, and endanger the normal operation of the power system. In order to better help field maintenance personnel to quickly and accurately find DC faults, our company has developed a DC fault finder by years of efforts and summing up a large number of field experiences. The DC grounding finder uses a high-precision current clamp meter to detect and locate faults using the DC current difference in the fault loop. The fast FFT transform technology is introduced into the DC fault finding device, to detect various types of insulation faults, DC mutual faults, and AC power failures in DC systems with different voltage level (24V (optiona... -
OEM Best megger price list Factories – GDF-3000A DC System Earth Fault Detector – HV Hipot
General Information DC system insulation faults, DC mutual faults and AC power failures are faults that are prone to occur and are harmful to the power system, and endanger the normal operation of the power system. In order to better help field maintenance personnel to quickly and accurately find DC faults, our company has developed a DC fault finder by years of efforts and summing up a large number of field experiences. The DC grounding finder uses a high-precision current clamp meter to detect and locate faults using the DC current difference in the fault loop. The fast FFT transform technology is introduced into the DC fault finding device, to detect various types of insulation faults, DC mutual faults, and AC power failures in DC systems with different voltage level (24V (optiona...