  • OEM Best Current Transformer Metering Manufacturers –  GDHG-108A CT/PT Tester – HV Hipot

    OEM Best Current Transformer Metering Manufacturers – GDHG-108A CT/PT Tester – HV Hipot

    GDHG-108A CT/PT Tester supports test voltage method to test bushings CTs which installed on transformer or inside switch-gear, suitable for the laboratory and on-site detection. Itcan be easily and conveniently done voltage current characteristic, transformer ratio, ratio and phase angle error, load test items on CT/PT. Features ● Using the voltage detection principle to measure CT and PT. ● To meet the requirements of GB1207, GB1208, GB168-47 (IEC60044-1.6) and other standards. ● No external auxiliary equipment, a single machine can complete all test items. ● With high speed micro printer: real-time print the test result. ● Using intelligent controller, operation is simple. ● 5inch LCD screen display. ● Automatically given CT/PT (excitation) knee point value. ● Auto display 5% and 1...
  • China High Quality Circuit Breaker Tester Factory –  GDHL-100HS 100A Handheld Contact Resistance Tester  – HV Hipot

    China High Quality Circuit Breaker Tester Factory – GDHL-100HS 100A Handheld Contact Resistance Tester – HV Hipot

    General Information The product is mainly used for the contact resistance of switch contacts and other micro-ohm resistance measurement, and the test speed is fast and the accuracy is high. This handheld contact resistance tester is an innovative product that is compact, hand-held, battery powered and easy to carry.  Features ● Maximum output current is 100A, two current levels are selectable ● Built-in large capacity lithium battery, it can perform more than 600 tests on one charge. ● The test is simple, the operation is convenient, and it can work continuously for more than 8 hours. ● In the 100A test, the longest test time can be up to 60 seconds, which can meet various usage scenarios on site. ● Wide range, high precision, up to 10mΩ at 100A. ● With complete protection functio...
  • OEM Best Handheld Sf6 Gas Detector Supplier –  GDFJ-311M SF6 Gas Decomposition Product Tester – HV Hipot

    OEM Best Handheld Sf6 Gas Detector Supplier – GDFJ-311M SF6 Gas Decomposition Product Tester – HV Hipot

    General Information GDFJ-311M SF6 Gas Decomposition Product Tester is a portable device designed to measure SF6 gas decomposition product. The core component with electrochemical sensor from Membrapor to test SF6 gas decomposition product. Besides, we also adopt professional hardware chips and excellent software algorithms of STMicroelectronics. Application Decomposition product analysis of SF6 gas insulated electrical equipment Quality detection of recycled SF6 gas R&D use Reference standard  DL/T 639-1997: Safety and Protection Guide for Operation Test and Maintenance Personnel of SF6 Electrical Equipment. Guodian No.72 Annex 3[1999] Measures for Quality Supervision and Management of High Voltage Switchgear. GB/T 17626: Electro-magnetic Compatibility – Testing and M...
  • OEM Best electrical power monitoring system Factory –  GDPQ-5000 Power Quality Analyzer – HV Hipot

    OEM Best electrical power monitoring system Factory – GDPQ-5000 Power Quality Analyzer – HV Hipot

    Introduction GDPQ-5000 Power Quality Analyzer is a comprehensive test instrument carefully developed by our company and specially designed for field test of three phases, multi-functional and intelligent, concise man-machine operation. It is easy to use, large LCD screen display, high resolution, interface in both Chinese and English, shock-proof shell structure and so on. Can simultaneously measure the 4-channel current (ABC three phase and neutral wire current), 4-channel voltage (ABC three-phase voltage and neutral line voltage to ground), the peak value of current voltage, maximum/minimum value over a period, three-phase imbalance factor, short-time voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor and displacement power factor, act...
  • OEM Best Insulator Faults Locator Exporters –  GDYZ-302 Wireless Zinc Oxide Surge Arrester Tester – HV Hipot

    OEM Best Insulator Faults Locator Exporters – GDYZ-302 Wireless Zinc Oxide Surge Arrester Tester – HV Hipot

    Product Description GDYZ-302 Zinc Oxide Arrester Live Tester is a special instrument used to test the electrical performance of Zinc Oxide Arrester. It is suitable for live or power-off detection of Zinc Oxide Arrester of various voltage levels, so that to found dangerous defects such as dampness of internal insulation and aging of valve plates in time. The instrument is simple to operate and easy to use. The entire measurement process is controlled by an industrial computer. It can measure the full current, resistive current and its harmonics, power frequency reference voltage and harmonics, active power and phase difference. Displays true waveforms of voltage and current. The instrument uses digital waveform analysis technology and software anti-interference methods such as harmoni...
  • OEM Best name the instrument used to measure the installtion resistance Manufacturers –  GDDT-10U Digital Grounding Down Lead Earth Continuity Tester – HV Hipot

    OEM Best name the instrument used to measure the installtion resistance Manufacturers – GDDT-10U Digital Grounding Down Lead Earth Continuity Tester – HV Hipot

    General Information GDDT-10U Earth Continuity Resistance Tester is a highly automatic and portable test equipment. It is applied to the measurement of breakover resistance value among earth connecting cables of substation electrical equipment. The adoption of high-performance single-chip control helps to achieve intelligence of testing process. It is small size, convenient to carry, easy to operate, high-accuracy, fast testing speed, good testing repeatability, clear to read. Features ● The instrument is controlled by high-speed single chip, thus it’s highly automatic and easy to operate.  ● Using new power source technology, with many more current steps and wide measuring range. ● Intelligent power management technology, the instrument can work in the state of Min. power, w...
  • OEM Best Portable Sf6 Gas Analyser Factories –  GDJD-3A SF6 gas Density Relay Calibrator – HV Hipot

    OEM Best Portable Sf6 Gas Analyser Factories – GDJD-3A SF6 gas Density Relay Calibrator – HV Hipot

    Product Description GDJD-3A SF6 gas Density Relay Calibrator is automatic calibrator, which uses embedded microprocessor to proceed performance calibration for all kinds of SF6 gas density relay. It is also a portable device which can make standard conversion for SF6 gas pressure at any environmental temperature. This device is mainly used for SF6 gas products production, maintenance and monitoring in power system. Features ● Automatically calibrate density relay and pressure gauge. ● Compact design, small size, and light weight, easy to carry. ● Color LCD screen, Windows menu. ● The power supply has UPS function, suitable for field operation. ● With mini-printer, to print test result directly. ● Good sealing property, do not waste SF6 gas during calibration. ● The two ends of con...
  • China High Quality Ct Pt Testing Equipment Supplier –  GDHG-106B  CT/PT Analyzer – HV Hipot

    China High Quality Ct Pt Testing Equipment Supplier – GDHG-106B CT/PT Analyzer – HV Hipot

    Features ● Finish all testing items by itself, no need to connect auxiliary equipment. ● Intelligent controller is adopted. ● Built-in printer, to print results easily. ● Large screen LCD, graphically display. ● Auto display excitation knee point value, 5% and 10% error curve. ● Save 3000 groups data and it is not lost after power down. ● With USB port. The data can be saved in USB disk and read by PC (WORD format file). ● Portable design, suitable for on-site test. ● Engineering plastic box with damping, strong and reliable. Specifications Main functions CT (protection type, metering type) PT Voltage current characteristic curve (excitation characteristic) Voltage current characteristic curve (excitation characteristic) Auto calculate knee point value Auto calculate knee p...
  • China High Quality devices used for relay testing Factories –  GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot

    China High Quality devices used for relay testing Factories – GDJB-II SECONDARY CURRENT INJECTION TEST SET – HV Hipot

    Features A. Working conditions 1. Power supply: AC 220V±10%,50Hz 2. Working environment: Temperature -10℃~40℃; Humidity: ≤85% 3. Atmosphere: 86-106kPa B. Output power supply 1. AC voltage: 0-220V/3A  Adjustable 2. AC current: 0-100A/7V (200A can be customized);  0-20A/25V  Adjustable; 0-5A/5V  Adjustable 3. DC voltage: 0-220V/3A  Adjustable 4. DC current:0-20A/25V 5. Fixed voltage output: DC 24V/48V/110V/220V 6. Current/Voltage accuracy: ±1%. C. Performance Index 1. Ammeter and voltmeter: 41/2 digit. 2. Digital millisecond meter: 0-99.9999s(999.999s can be customized) Resolution: 0.1ms. D. Functions 1. Measure relay: Measure start value, return value and drop-off to pick-up ratio of current, voltage relay. 2. Time relay: Measure start value, return value and action time. 3. Intermed...
  • OEM Best 5kv insulation tester Suppliers –  GDDT-10U Digital Grounding Down Lead Earth Continuity Tester – HV Hipot

    OEM Best 5kv insulation tester Suppliers – GDDT-10U Digital Grounding Down Lead Earth Continuity Tester – HV Hipot

    General Information GDDT-10U Earth Continuity Resistance Tester is a highly automatic and portable test equipment. It is applied to the measurement of breakover resistance value among earth connecting cables of substation electrical equipment. The adoption of high-performance single-chip control helps to achieve intelligence of testing process. It is small size, convenient to carry, easy to operate, high-accuracy, fast testing speed, good testing repeatability, clear to read. Features ● The instrument is controlled by high-speed single chip, thus it’s highly automatic and easy to operate.  ● Using new power source technology, with many more current steps and wide measuring range. ● Intelligent power management technology, the instrument can work in the state of Min. power, w...
  • OEM Best Sf6 Gas Purity Test Ofcircuit Breaker Exporters –  GDFJ-311M SF6 Gas Decomposition Product Tester – HV Hipot

    OEM Best Sf6 Gas Purity Test Ofcircuit Breaker Exporters – GDFJ-311M SF6 Gas Decomposition Product Tester – HV Hipot

    General Information GDFJ-311M SF6 Gas Decomposition Product Tester is a portable device designed to measure SF6 gas decomposition product. The core component with electrochemical sensor from Membrapor to test SF6 gas decomposition product. Besides, we also adopt professional hardware chips and excellent software algorithms of STMicroelectronics. Application Decomposition product analysis of SF6 gas insulated electrical equipment Quality detection of recycled SF6 gas R&D use Reference standard  DL/T 639-1997: Safety and Protection Guide for Operation Test and Maintenance Personnel of SF6 Electrical Equipment. Guodian No.72 Annex 3[1999] Measures for Quality Supervision and Management of High Voltage Switchgear. GB/T 17626: Electro-magnetic Compatibility – Testing and M...
  • OEM Best Hipot Test Manufacturers –  50kV AC DC Dielectric Test Equipment GDYD-53D – HV Hipot

    OEM Best Hipot Test Manufacturers – 50kV AC DC Dielectric Test Equipment GDYD-53D – HV Hipot

    Application AC hi-pot testing is the effective and direct way to test insulation strength for electrical equipment, apparatus, or machines. It checks dangerous flaws which assure electrical equipment continuous working. Typical applications include testing of transformers, switchgear, cables, capacitors, aerial motors platforms, hot sticks bucket bricks, vacuum bottles and other related equipment like vacuum interrupters, blankets, ropes, gloves, hydraulics hose, instruments transformers generators. Features ● Digital display panel mounted controls & indicators with easy-to-read legend. ● Monitoring high voltage side voltage, low voltage side current and indicator of zero, power, working start, timing. ● Over-current protection, zero-starting protection, sound, and light alarm. ● Co...