  • China High Quality Circuit Breaker Test Sets Supplier –  GDKC-15 Series Circuit Breaker Analyzer – HV Hipot

    China High Quality Circuit Breaker Test Sets Supplier – GDKC-15 Series Circuit Breaker Analyzer – HV Hipot

    General Information High voltage circuit breaker is one of the most important control equipment in the power system. GDKC-15 Series is used to test the dynamic characteristics of high voltage circuit breaker. It is easy to operate, with high accuracy. GDKC-15 Series GDKC-15A GDKC-15B GDKC-15C GDKC-15D GDKC-15E GDKC-15F GDKC-15G GDKC-15H Metal contact 12 12 12 12 12 12 12 12 Closing resistance 6 6 6 6 6 6 6 Graphite contact 3 3 3 3 6 Double-ended grounding 3 3 3 6 Dynamic resistance(Pre-insertion resistor) 1 1 3 3 3 3 6 Static resistance 1 1 3 3 3 3 6 Ground resistance 3 6 Features ● It is suitable for the mechanical test of all types of SF6 switches, GIS combination appliances, vacuum switches and oil switches. ● Strong anti-interference ability. It ...
  • OEM Best Cable Detector Supplier –  GD-2134A Cable Identifier – HV Hipot

    OEM Best Cable Detector Supplier – GD-2134A Cable Identifier – HV Hipot

    The purpose of the cable identifier is to accurately identify one of the target cables from multiple cables and avoid serious accidents caused by wrong sawing of live cables. Cable identification starts from the operation of both ends of the cable, it must be ensured that the double number on both ends of the cable is accurate. GD-2134A Cable Identifier is only suitable for on-site identification of de-energized cables. It is strictly forbidden to connect the cable identifier to the running power cable! Features ● Handheld receiver automatically identify and display the results to ensure that the results of cable identification are 100% accurate. Light weight and powerful, easy to carry. ● Suitable for on-site identification of de-energized cables. ● Both transmitter and handheld re...
  • OEM Best closed cup flash point determine Manufacturer –  GDZL-50L Oil Filtration Machine – HV Hipot

    OEM Best closed cup flash point determine Manufacturer – GDZL-50L Oil Filtration Machine – HV Hipot

    General Information The machine GDZL-50L can effectively remove moisture, gas and impurities in the insulating oil, improve the pressure resistance of the oil and the quality of the oil, to ensure the safe operation of the power equipment. It is mainly used in the power sector and industrial and mining enterprises to deal with unqualified transformer oil, transformer oil, switch oil and so on. Features ● Small size and high efficiency, easy to move. It is especially suitable for live working on site. It also can dry the moisture of power equipment, and conveniently vacuum the power equipment. ● Infrared liquid level automatic control device, system pressure automatic protection device and high-efficiency degassing components are adopted in the structure. The operation is convenient and ...
  • OEM Best types of partial discharge Factory –  GDJF-2007 Digital Partial Discharge Analyzer – HV Hipot

    OEM Best types of partial discharge Factory – GDJF-2007 Digital Partial Discharge Analyzer – HV Hipot

    Picture only for reference first. GDJF-2007 Digital Partial Discharge Analyzer is widely used for detecting partial discharge of high voltage equipment such as power transformers, instrument transformer, HV circuit breaker, GIS, Zinc oxide surge arrester, power cable. It also can make type tests and monitor insulation operation. It includes main unit, PD software, current transformer, input unit, calibration pulse generator, input adapter, antenna amplifier and connection cable etc. Features ● 12inch LCD display, with portable design, rugged and durable, easy to use. ● Strong anti-interference ability, accurate. Using digital filtering technology, field interference can be effectively eliminated, and partial discharge measurement can be realized in a strong interference environmen...
  • China High Quality Sf6 Dew Point Tester Suppliers –  GDSF-311WP SF6 Dew Point and Purity Tester  – HV Hipot

    China High Quality Sf6 Dew Point Tester Suppliers – GDSF-311WP SF6 Dew Point and Purity Tester – HV Hipot

    General Information GDSF-311WP is ideal instrument when it is necessary to test water content and purity of SF6 gas. The core component is DRYCAP series sensors produced by Finland Vaisala company. With professional hardware chips and excellent software algorithms of STMicroelectronics, we have produced a new generation of gas moisture test instrument. Application ● Moisture monitoring of SF6 gas electrical equipment for electric power ● SF6 gas cylinder gas quality test ● High purity gas manufacturing ● Semiconductor industry dry gas supply ● Research and development use ● Clean room/dry house monitoring ● Metal heat treatment site and laboratory industrial gas humidity detection, such as air, CO2, N2, H2, O2, SF6, He, Ar and other inert gases. Features Specification SF6 ...
  • China High Quality electrical power monitoring system Exporters –  GDYM-3F  Portable Multi-functional Energy Meter Calibrator  – HV Hipot

    China High Quality electrical power monitoring system Exporters – GDYM-3F Portable Multi-functional Energy Meter Calibrator – HV Hipot

    Features ● Synchronously calculate all parameters and display on the interface include full wave, fundamental wave and harmonic wave as the same time show U, I, P, Q, VA, phase angle about full wave and fundamental wave as well as the harmonic synthesis of I, U, P, Q, VA and its percentage, the content of U, I positive sequence, negative sequence, zero sequence and harmonics of PH+, PH-, PH+/Pf%, PH-/Pf%, full wave PF, fundamental wave PF, harmonic wave PF. ● Inspection method include 7 kinds of ways of full wave active, full wave reactive power, full wave apparent, fundamental wave active, fundamental wave reactive power, fundamental wave apparent and harmonic wave, which can check the active power accuracy of full wave meter, fundamental meter, harmonic wave meter and the reactive ...
  • OEM Best Gas Moisture Measurement Supplier –  GDJD-3A SF6 gas Density Relay Calibrator – HV Hipot

    OEM Best Gas Moisture Measurement Supplier – GDJD-3A SF6 gas Density Relay Calibrator – HV Hipot

    Product Description GDJD-3A SF6 gas Density Relay Calibrator is automatic calibrator, which uses embedded microprocessor to proceed performance calibration for all kinds of SF6 gas density relay. It is also a portable device which can make standard conversion for SF6 gas pressure at any environmental temperature. This device is mainly used for SF6 gas products production, maintenance and monitoring in power system. Features ● Automatically calibrate density relay and pressure gauge. ● Compact design, small size, and light weight, easy to carry. ● Color LCD screen, Windows menu. ● The power supply has UPS function, suitable for field operation. ● With mini-printer, to print test result directly. ● Good sealing property, do not waste SF6 gas during calibration. ● The two ends of con...
  • OEM Best Voltage Tester Supplier –  GDCY-20B 20kV Impulse Voltage Tester (Basic Type) – HV Hipot

    OEM Best Voltage Tester Supplier – GDCY-20B 20kV Impulse Voltage Tester (Basic Type) – HV Hipot

    GDCY-20B Programmable Automatic Impulse Voltage Tester is mainly based on TB/T 2653, GB/T 17627, GB/T 16927, GB14048, GB7251, GB/T 16935, IEC 61730, GB4706, GB3048, JB/T 7083 and other standard requirements. It is mainly used for safety performance (dielectric performance) detection of low-voltage electrical appliances, high and low voltage switches, solar energy, electricity meters, relays, leakage protectors, etc. The impulse output can be controlled by computer, and the test report can be printed and generated. Features ● Manual/automatic/programmable mode: Manual mode adjusts impulse voltage manually by adjusting knob; Automatic mode adjusts impulse voltage automatically by the system; Programmable mode uses computer to control impulse voltage automatically. ● Automatic mode and ...
  • China High Quality digital meter price Suppliers –  GD3128 Series Insulation Resistance Tester – HV Hipot

    China High Quality digital meter price Suppliers – GD3128 Series Insulation Resistance Tester – HV Hipot

    General Information GD3128 series Insulation Resistance Tester has perfect testing function of various insulation resistance parameters and excellent anti-interference ability, which can be used to test the insulation resistance of large capacity high voltage electrical equipment and transmission lines in strong inductive environment such as substation. The instrument adopts true color touch screen, all test data and battery power are displayed on the same screen at a glance, and the combination of knob switch and key makes the operation very simple. The user does not need to memorize the operation method. Click “HELP” on the screen to pop up the operation method, which can effectively guide the user to operate the instrument. The instrument has the function of fast disch...
  • OEM Best petroleum flash point tester Exporters –  GDYN-901 Kinematic viscosity tester – HV Hipot

    OEM Best petroleum flash point tester Exporters – GDYN-901 Kinematic viscosity tester – HV Hipot

    General Information  GDYN901 is suitable to determine kinematic viscosity of liquid petroleum products. This apparatus has the function of timing of the trial sample movement and can calculate the final result of kinematic viscosity. This method is suitable to determine kinematic viscosity of liquid petroleum products (It refers to Newtonian liquids ), and its unit is m2/s. Generally in actual utilization, the unit is mm2/s. The dynamic viscosity is equal with the result which use kinematic viscosity to multiply the density of the liquid. By this method, it can determine the time that the liquid with the certain volume flows past the calibrated glass capillary viscometer under the gravity in the certain stable temperature and the value that the constant value of capillary in the visc...
  • China High Quality insulator flaw detector Exporters –  GDJW-40B  Wireless Insulator Tester – HV Hipot

    China High Quality insulator flaw detector Exporters – GDJW-40B Wireless Insulator Tester – HV Hipot

    General Information GDJW-40B can be used to test the distribution voltages of the charged suspended insulator or the laboratory detection of the suspended insulator, and enable to effectively detect the internal hidden trouble of the insulator, improve the operating reliability of the power grid system, and improve the working efficiency of the line staff who carries out the live testing. This product adopts wireless transmission, the communication distance between detector and hand-held terminal can up to 100m above, Make the measurement process truly safe and reliable, fast and accurate. In addition, the instrument has a very strong anti-interference performance, fully comply with (EMC) standard requirements, adapt to a variety of electromagnetic field interference situation. Fe...
  • China High Quality harga megger Factories –  GD2000D Insulation Resistance Tester – HV Hipot

    China High Quality harga megger Factories – GD2000D Insulation Resistance Tester – HV Hipot

    General Information GD2000D digital insulation resistance tester produced by our company uses an embedded industrial single chip real-time operating system. The digital analog pointer and digital field code display are perfectly combined. This series of meters has a variety of voltage output levels (250V, 500V, 1000V, 2500V, 5000V, 10000V), large capacity, strong anti-interference, analog pointer and digital synchronous display, AC and DC dual-use, simple operation, automatic calculation of various insulation indicators (absorption ratio, polarization index), various measurement results with anti-power-down function, etc. It is an ideal test instrument for measuring the insulation resistance of large-capacity transformers, transformers, generators, high-voltage motors, power capacito...